Part Number

Search

450JB001M14

Description
Connector Designator J Direct Coupling
File Size20KB,1 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet View All

450JB001M14 Overview

Connector Designator J Direct Coupling

Direct Coupling (Straight)
Rotatable Coupling (45° and 90° Elbows)
450 J S 001 M 16 G
CONNECTOR
DESIGNATOR
Product Series
Connector Designator
Angle and Profile
A = 90
B = 45
S = Straight
Ground Lug (Omit for none)
Shell Size (Table I)
Finish (Table II)
Basic Part Number
J
A Thread
(Table I)
F
G
H
B
(Table I)
E
C (Table I)
C (Table I)
J
STRAIGHT
DIRECT COUPLING
.140 (3.6) Dia (Typ.)
Ground Lug
(Optional)
45°
ROTATABLE COUPLING
E
Use MS3367-1 Tie
Strap or Equivalent
(Typical)
E
90°
ROTATABLE COUPLING
See inside back cover fold-out or pages 13 and 14 for Tables I and II.
Shell
Size
08
10
14
16
18
20
22
24
E
Cable Entry
.375 (9.5)
.500 (12.7)
.750 (19.1)
.875 (22.2)
1.000 (25.4)
1.125 (28.6)
1.250 (31.8)
1.375 (34.9)
TABLE III: DIMENSIONS
G
F
Max
Max
1.250 (31.8) 1.630 (41.4)
1.250 (31.8) 1.670 (42.4)
1.500 (38.1) 2.200 (55.9)
1.500 (38.1) 2.270 (57.7)
1.500 (38.1) 2.330 (59.2)
1.500 (38.1) 2.410 (61.2)
1.500 (38.1) 2.550 (64.8)
1.500 (38.1) 2.590 (65.8)
H
Max
.750 (19.1)
.750 (19.1)
.750 (19.1)
.780 (19.8)
.780 (19.8)
.810 (20.6)
.810 (20.6)
.810 (20.6)
J
Max
.940 (23.9)
1.000 (25.4)
1.380 (35.1)
1.460 (37.1)
1.510 (38.4)
1.560 (39.6)
1.630 (41.4)
1.710 (43.4)
1. Cable Entry is defined as the accommodation entry for the wire bundle or cable.
Dimensions are not intended for inspection criteria.
2. Metric dimensions (mm) are indicated in parentheses.
© 2005 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
Series 45 - Page 7
45
450-001
Qwik-Ty® Strain Relief - Connector Designator J
How to determine the row and column of the pressed key in a matrix keyboard scanning program written in C language?
One method is to assign 1110 1101 1011 0111 to the low bits, and then scan. I saw another method in a book. It is to judge the row and column respectively. [code] //The following code is copied from a...
wuh2003 Programming Basics
A newbie, please give me some advice about using ADC10 to measure temperature on launchpad.
WDTCTL = WDTPW + WDTHOLD; // Stop watchdog ADC10CTL1 = ADC10DIV_3 + INCH_10 + SHS_1 + CONSEQ_2; // TA trig., rpt, A10 ADC10CTL0 = SREF_1 + ADC10SHT_3 + REF2_5V + ADC10IE + REFON + ADC10ON; // __enable...
taotiezh Microcontroller MCU
Good resources of the week - a new wave of PCB materials is coming
{:1_102:}{:1_102:}{:1_102:} The download center has a new wave of PCB materials, which look good. If you need them, please download them~~ [url=https://download.eeworld.com.cn/detail/1498227845/559719...
okhxyyo PCB Design
The seven most downloaded classic FPGA books (Part 3)
[align=center][/align] [font=微软雅黑] [url=https://download.eeworld.com.cn/detail/tiankai001/4135][size=5][b]Learn to use CPLD in 5 minutes[/b][/size][/url][/font] [font=微软雅黑][size=4]This article introdu...
高进 Download Centre
Switching Power Supply Design Guide
eeworldpostqq...
抛砖引玉 Power technology
Please recommend a TI high-speed op amp with a bandwidth of more than 100M
[i=s] This post was last edited by dontium on 2015-1-23 12:51 [/i] It is used to amplify small signals with a frequency of 1M. Amplify 50MV to 5V....
15202837764 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2801  1187  1909  1212  2789  57  24  39  25  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号