55.12.8.060.00940

Description
Electromechanical Relay, DPDT-CO, MBB, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.12.8.060.00940 Overview

Electromechanical Relay, DPDT-CO, MBB, AC/DC Output

55.12.8.060.00940 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)48 V
Coil resistance1200 Ω
Maximum coil voltage (AC)66 V
Nominal coil voltage60 V
Coil/Input Power TypeAC
Contact (AC) maximum rated power R load2500VA@400VAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life200000 Cycle(s)
End contact materialSILVER NICKEL
Number of terminals8
operating hours10 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count8
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style2 FORM C
Relay functionDPDT-CO
release time5 ms
Terminal length0.0048 inch
Termination typeSOLDER
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
Embedded USB driver-free device communication method based on WinUSB
In order to simplify the development of USB devices and access to PC systems, Microsoft developed WinUSB, which can install Winusb.sys as a device function driver and provide WinUSB API for applicatio...
Aguilera Microcontroller MCU
2011 MCU Day - 20-city tour registration is now open
Since the MSP430 series of microcontrollers entered the Chinese market in 1999, they have been favored by engineers for their ultra-low power consumption and high performance. In the 2011 MCU DAY semi...
莫妮卡 Microcontroller MCU
Study shows men are more emotionally engaged than women
[b][color=#008080]1-5 years old Girl: Mom Boy: Mom 6-10 years old Girl: Not a nasty boy Boy: Brother who can accompany me to bully girls 11-15 years old Girl: Big brother in his teens, 15s, 16s, 17s, ...
simonprince Talking
Data Accuracy for Power Management
Generally, the phase-to-phase voltage range of the closed line and the through line is between 0V-300V, and the current range is between 0A-100A. Considering the instantaneous overvoltage and overcurr...
zbz0529 Power technology
[Help] 430 ST7920 with font library 12864 drawing points failed
I'm asking for help from the almighty netizens. I used the dotting program, but it turned out to be a few lines. I saw someone say it was because the extended instruction set was not turned on, but I ...
常见泽1 Microcontroller MCU
Application of Chemical Vapor Deposition in Back-end Process of Integrated Circuit Manufacturing
Application of Chemical Vapor Deposition in Back-end Process of Integrated Circuit Manufacturing[Source: "Semiconductor Technology"] [Author: Yi Wanbing1,2,3, Tu Ruineng1, Zhang Bingyi1, Wu Jin1, Mao ...
fighting PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 327  2818  808  803  1967  7  57  17  40  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号