MAH201027-30.001MHZ

Description
HCMOS Output Clock Oscillator, 30.001MHz Nom, DIP-14/4
CategoryPassive components    oscillator   
File Size583KB,2 Pages
ManufacturerILSI
Websitehttp://www.ilsiamerica.com
Download Datasheet Parametric View All

MAH201027-30.001MHZ Overview

HCMOS Output Clock Oscillator, 30.001MHz Nom, DIP-14/4

MAH201027-30.001MHZ Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerILSI
package instructionDIP4/14,.3
Reach Compliance Codecompliant
maximum descent time6 ns
Frequency Adjustment - MechanicalNO
frequency stability10%
Installation featuresTHROUGH HOLE MOUNT
Number of terminals14
Nominal operating frequency30.001 MHz
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
Oscillator typeHCMOS
Output load50 pF
Encapsulate equivalent codeDIP4/14,.3
physical size20.7mm x 13.1mm x 5.08mm
longest rise time6 ns
Maximum slew rate40 mA
Maximum supply voltage2.75 V
Minimum supply voltage2.25 V
Nominal supply voltage2.5 V
surface mountNO
maximum symmetry40/60 %
MAH Series 14 Pin DIP Oscillator

Industry Standard Package

RoHS Compliant Available

HCMOS Output

Wide Frequency Range
Frequency Range
Frequency Stability (Inclusive of Temperature, Load, Voltage and
Aging)
Operating Temperature
Storage Temperature
Waveform
Logic “0”
Logic “1”
Duty Cycle 50% of Waveform
Load
Start Up Time
Rise/Fall Time
Standby Current Consumption
Supply Voltage (VDC ±10%) – Supply Current (in mA max)
32.728kHz to 1.000MHz
1.001MHz to 24.000MHz
24.001MHz to 50.000MHz
50.001MHz to 70.000MHz
70.001MHZ to 200.000MHZ
24.000MHz to 30.000MHz
30.001MHz to 80.000MHz
32.768 kHz to 200.000 MHz
See Part Number Guide
See Part Number Guide
-55°C to +125°C
HCMOS
10% Vdd max
90% Vdd min
See Part Number Guide
50pF max
10mSec max
Up to 70.000MHZ
Above 70.000MHZ
100µA
+5.0
+3.3
35
10
45
25
55
35
60
35
85
40
NA
NA
NA
NA
6 nSec max
4 nSec max
+2.5/+1.8
NA
NA
NA
NA
NA
20
40
Environmental & Mechanical Detail
Shock
Solderability
Solvent Resistance
Vibration
Gross Leak Test
Fine Leak Test
MSL
MIL-STD-883, Method 2002 Cond B
MIL-STD-883, Method 2003
MIL-STD-202, Method 215
MIL-STD-883, Method 2007, Cond A
MIL-STD-883, Method 1014, Cond C
MIL-STD-883, Method 1014, Cond A2
Level 1 per IPC/JEDEC J-STD 20
Marking Detail
Line 1 = MXXXXX
M =
XXXXX =
Line 2 = SYYWWL
S =
=
YYWW
MMD
Frequency in MHZ
Internal Code
4 Numerical Digit Date
Code (Year / Week)
Denotes RoHS Compliant
L =
Line 3 = XXXXX
Internal use only
May vary with lots
Pin 1 Designator
MMD Monitor/Quartztek
5458 Louie Lane, Reno, NV 89511
Phone: (775) 851-8880, Fax: (775) 851-8882,
www.mmdcomp.com
In the event of conflict, the requirements of this specification shall govern.
Revisions only with customer approval
Revision:
08/23/16 H
Pg 1 of 2
C2000 floating point calculation notes - differences between CPU and CLA and error handling techniques
The C2000 microprocessor with C28x+FPU architecture adds some registers and instructions to the original C28x fixed-point CPU to support IEEE single-precision floating-point operations. The floating-p...
Jacktang Microcontroller MCU
Problems that may occur after the completion of security projects and their solutions
After listening to Mr. Feng's advice, I think this article is good, so I forward it here for everyone to learn:...
soso Industrial Control Electronics
Model-based design subverts traditional FPGA development methods!
Recently, I compared the comprehensive results of handwritten HDL code (21 lines); code generated by DSP Builder (>200 lines); and code generated by Simulink HDL Coder (>200 lines) on the same experim...
平湖秋月 FPGA/CPLD
LED flashing drive circuit diagram analysis
I recently drew a fast-response LED flashing drive circuit. After many changes, I think the circuit is relatively reasonable, but it still crashes after a long time of simulation. I hope you can help ...
Ansami Analog electronics
[Help] Can I use shift instructions on IAR? ? I can't use it!!
Shift variable a to the left: a>>3;shift right abut I can't use it on IAR. The system warns that it doesn't work. Is there any alternative? Will using multiplication and division affect the speed? ?...
raiderchina Microcontroller MCU
Future Development of Industrial Ethernet
There is still a long way to go to achieve a unified and operable industrial Ethernet.From the above discussion, it is not difficult to see that large automation system companies use industrial Ethern...
wdxyx Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 684  843  536  728  2173  14  17  11  15  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号