PRODUCT INFORMATION
ÖLFLEX® 150
Oil resistant multi-standard cable with H05VV5-F and AWM approval
ÖLFLEX® 150 - H05VV5-F harmonised PVC control cable with UL/CSA AWM, oil-resistant, flexible and numbered for various
applications, U
0
/U: 300/500 V
Info
Oil-resistant according to EN 50363-4-1: TM5
Harmonised (HAR): H05VV5-F and UL recognized
Oil-resistant
Good chemical resistance
Benefits
Wide application range due to multiple certifications
Application range
Plant engineering
Industrial machinery
Heating and air-conditioning systems
Machine tools
Mainly used in dry, damp and wet interiors (including water-oil mixtures), but not for outdoor use
For fixed installation under medium mechanical load conditions, and applications with occasional flexing at free, non-
continuously recurring movement without tensile load or compulsory guidance
Note: for the use of AWM (Appliance Wiring Material) cables in industrial machinery (USA) according to NFPA 79 Ed. 2015:
please see the catalogue appendix table T29
Last Update (21.11.2016)
©2016 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
PRODUCT INFORMATION
ÖLFLEX® 150
Product features
Flame-retardant according to IEC 60332-1-2
and UL 1581 §1061 Cable Flame Test
Oil-resistant according to EN 50363-4-1: TM5
Norm references / Approvals
H05VV5-F (EN 50525-2-51)
UL AWM Style 21098
CSA AWM I A/B II A/B
Multi-standard cables have conductor strands with nominal sizes in mm²
or
AWG/kcmil. The master size is mentioned in the
table below, while the equivalent size of the other system can be found in the Appendix T16 of this catalogue. For this related
secondary size the cross-section of the conductor mostly works out to be greater than the
specified nominal value.
Product Make-up
Fine-wire strand made of bare copper wires
PVC core insulation
Cores twisted in layers
PVC outer sheath, high oil-resistance, grey (RAL 7001)
Technical Data
Classification:
ETIM 5.0 Class-ID: EC000104
ETIM 5.0 Class-Description: Control cable
Black with white numbers acc. to VDE 0293-1
Fine wire according to VDE 0295,
class 5/IEC 60228 class 5
Occasional flexing: 12.5 x outer diameter
Fixed installation: 4 x outer diameter
HAR U
0
/U: 300/500 V
UL/CSA: 600 V
3000 V
G = with GN-YE protective conductor
X = without protective conductor
Occasional flexing:
HAR: -5°C to +70°C
UL/CSA: -5°C to +90°C
Fixed installation:
HAR: -40°C to +70°C
UL/CSA: -40°C to +90°C
Core identification code:
Conductor stranding:
Minimum bending radius:
Nominal voltage:
Test voltage:
Protective conductor:
Temperature range:
Last Update (21.11.2016)
©2016 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
PRODUCT INFORMATION
ÖLFLEX® 150
Note
Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon
request.
Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related
surcharges.
Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
Please specify the preferred type of packaging (e.g. 1 x 600 m drum or 8 x 75 m coils).
Photographs are not to scale and do not represent detailed images of the respective products.
* Prices are net prices without VAT and surcharges. Sale to business customers.
Last Update (21.11.2016)
©2016 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
Powered by TCPDF (www.tcpdf.org)
ÖLFLEX® 150
Article number
ÖLFLEX® 150
0015002
0015003
0015004
0015005
0015007
0015012
0015018
0015025
0015034
0015041
0015102
0015103
0015104
0015105
0015107
0015112
0015118
0015125
0015134
0015141
0015202
0015203
0015204
0015205
0015206
0015207
0015212
0015218
0015225
0015234
0015241
0015250
0015302
Number of cores and mm² per
conductor
2 X 0.5
3 G 0.5
4 G 0.5
5 G 0.5
7 G 0.5
12 G 0.5
18 G 0.5
25 G 0.5
34 G 0.5
41 G 0.5
2 X 0.75
3 G 0.75
4 G 0.75
5 G 0.75
7 G 0.75
12 G 0.75
18 G 0.75
25 G 0.75
34 G 0.75
41 G 0.75
2X1
3G1
4G1
5G1
6G1
7G1
12 G 1
18 G 1
25 G 1
34 G 1
41 G 1
50 G 1
2 X 1.5
Outer diameter (mm)
Copper index (kg/km)
Weight (kg/km)
Last Update (21.11.2016)
©2016 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
5.9
6.2
6.8
7.4
9
11.1
13.2
16
18.1
19.7
6.3
6.7
7.2
8.1
9.9
12
14.4
17.1
19.7
21.6
6.6
7
7.8
8.6
9.5
10.4
12.8
15.1
18
20.9
22.8
25
7.6
9.6
14.4
19.2
24
33.6
58
86.4
120
164
197
14.4
21.6
28.8
36
50
86
130
180
245
296
19.2
28.8
38.4
48
57.6
67
115
173
240
326
394
480
28.8
47
62.4
68.2
87.1
118.7
198
328
380.4
509
595
61
75.6
83.9
113.3
145
244.9
327.7
466.4
626.5
748
80
79
98.6
132.1
150
169.3
285.9
405.2
569.5
741.7
886
1,072.2
95
PRODUCT INFORMATION
Powered by TCPDF (www.tcpdf.org)
Powered by TCPDF (www.tcpdf.org)
ÖLFLEX® 150
Article number
0015303
0015304
0015305
0015307
0015312
0015318
0015325
0015334
0015341
0015402
0015403
0015404
0015405
0015407
0015412
0015418
0015425
Number of cores and mm² per
conductor
3 G 1.5
4 G 1.5
5 G 1.5
7 G 1.5
12 G 1.5
18 G 1.5
25 G 1.5
34 G 1.5
41 G 1.5
2 X 2.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
12 G 2.5
18 G 2.5
25 G 2.5
Outer diameter (mm)
8.3
9
10.1
12.5
15.1
18
21.4
25
27.2
9.2
9.9
10.8
12.1
14.7
17.9
21.6
25.6
Copper index (kg/km)
43
58
72
101
173
259
360
490
591
48
72
96
120
168
288
432
600
Weight (kg/km)
109.8
145
168
224.2
361.7
518.3
729.9
946.6
1136
159
170
210
257
340
580
850
1166
Last Update (21.11.2016)
©2016 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
PRODUCT INFORMATION