EEWORLDEEWORLDEEWORLD

Part Number

Search

55.14.8.060.5031

Description
Electromechanical Relay, 4PDT-CO, MBB, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.14.8.060.5031 Overview

Electromechanical Relay, 4PDT-CO, MBB, AC/DC Output

55.14.8.060.5031 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)48 V
Coil resistance1200 Ω
Maximum coil voltage (AC)66 V
Nominal coil voltage60 V
Coil/Input Power TypeAC
Contact (AC) maximum rated power R load1750VA@250VAC
Contact (AC) maximum rated R load15A@250VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)250 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life150000 Cycle(s)
End contact materialSILVER NICKEL
End contact platingGold
Number of terminals14
operating hours11 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count14
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style4 FORM C
Relay function4PDT-CO
release time3 ms
Terminal length0.0048 inch
Termination typeSOLDER
Base Number Matches1
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
How to measure LED brightness
[hideLike traditional light sources, the optical measurement units of LED light sources are unified. In order to make readers understand and use it conveniently, the following is a brief introduction ...
探路者 LED Zone
VISHAY Lighting Theme Month Event, did you win a prize?
This year's Vishay event will be in the form of a lottery. You will know whether you have won a prize after the challenge is over!I posted the picture, I won the first prize! :victory: What prize were...
小煜 Discrete Device
TI BQ2060 English translate Chinese the segment datasheet!
bq2060 Specification Features: *. Can accurately measure the charging of nickel-cadmium, nickel-manganese, lithium-ion and lead-acid batteries *. Support SBS V1.1 version *. Support two-line SMBus V1....
zbz0529 Energy Infrastructure?
A classic book on switching power supplies
This book explains in detail the design of forward and flyback switching power supplies, including inductance calculation and core selection, and is very suitable for engineers who are just getting st...
zengquan Power technology
I have a question about battery voltage sampling?
I need to design a battery voltage detection circuit. I only need to detect the current voltage and send the sampled voltage directly to the microcontroller through AD conversion. Do I need to add a v...
hunenghl Analog electronics
My understanding of 3G (transferred)
After communicating with all parties, my understanding is as follows: (1) China's principles in choosing 3G technology: practical, inexpensive, and waiting; (2) China is not deliberately waiting for T...
john_wang RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 875  1904  229  2571  1372  18  39  5  52  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号