EEWORLDEEWORLDEEWORLD

Part Number

Search

G81214461AAEU

Description
Board Connector
CategoryThe connector    The connector   
File Size77KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

G81214461AAEU Overview

Board Connector

G81214461AAEU Parametric

Parameter NameAttribute value
Objectid1926739759
Reach Compliance Codeunknown
ECCN codeEAR99
Connector typeBOARD CONNECTOR
Manufacturer's serial numberG812
Amphenol
Miniature Box Interconnects
G812
Materials
Housing
Contacts
– 94V-0 thermoplastic
– P/B with 50µ” Ni
– 1A
– 250 VAC/rms 60Hz
2.54mm IDC Receptacle for Ribbon Cable
A
Ideal for 28AWG 1.27mm pitch ribbon cable. Available with or without strain relief with optional
central polarising key (CPK)
Durability
Gold Flash
15µ” Gold
30µ” Gold
Latch Headers
Box Headers
Pin Headers
Cable
– 75 cycles
– 150 cycles
– 250 cycles
– Page G-24
– Page G-24
– Page G-17/18/19
– Page
T-1
Electrical
Current
Voltage
Mating Half/Accessories
A
Part Number System:
G812 XX XX X X X
IDC Sockets
2.54mm Pitch
NUMBER OF POSITIONS
10: 10 Position
14: 14 Position
16: 16 Position
20: 20 Position
26: 26 Position
30: 30 Position
34: 34 Position
40: 40 Position
50: 50 Position
60: 60 Position
64: 64 Position
Various other positions available on request
Suffix may be added to Part Number.
This Suffix is for Internal use mainly.
Additional Suffix ‘EU’ or ‘LF’ may be
added for RoHS compliant product.
CONTACT FINISH
AA: Gold flash
18: 15µ” Gold
34: 30µ” Gold
STRAIN RELIEF OPTION
1: Without strain relief
4: With strain relief
INSULATOR COLOUR
33: Gray
34: Gray w/o CPK
45: Black
46: Black w/o CPK
20
29.91
Dimensions in mm
A
Positions
Dim A
10
17.21
14
22.29
16
24.83
26
37.53
30
42.61
34
47.81
40
55.50
50
68.15
60
80.90
64
86.10
PNS-8125 Rev.B/SKT-G812XX334AACA-16 Rev. A
G806
Materials
Housing
Contacts
Finish
2.54mm IDC Transition Plug for Ribbon Cable
Electrical
– 94V-0 thermoplastic
– Brass
– Gold Flash/75 Cycles
Current
Voltage
– 1A
– 250 VAC/rms 60Hz
– Page
T-1
Ideal for 28AWG 1.27mm pitch ribbon cable. Available with or without strain relief.
Accessories
Cable
Part Number System:
G806 XX XX XX X 00 X X
I
DC Plug-in
2.54mm Pitch
NUMBER OF POSITIONS
10: 10 Position
14: 14 Position
16: 16 Position
20: 20 Position
26: 26 Position
30: 30 Position
34: 34 Position
40: 40 Position
50: 50 Position
60: 60 Position
64: 64 Position
Various other positions available on request
Suffix may be added to Part Number.
This Suffix is for Internal use mainly.
Additional Suffix ‘EU’ or ‘LF’ may be
added for RoHS compliant product.
Dimensions in mm
INSULATOR COLOUR
1: Black
2: Gray
PC TAIL LENGTH
2: 3.5mm
CABLE STOP OPTION
00: Without cable stop
11: With cable stop
STRAIN RELIEF OPTION
00: Without strain relief
11: With strain relief
20
30.52
Recommended PCB Layout
Positions
Dim A
AMTA
10
17.82
14
22.90
16
25.44
26
38.14
30
43.14
34
48.30
40
55.92
50
68.62
60
81.32
64
86.40
PNS-8063 Rev.D/SKT-G806XX00-16 Rev. C
G-25
ESP8266 Ready-made Programs
[i=s] This post was last edited by e9996 on 2016-3-2 16:29 [/i] Both AP mode and static mode of ESP8266 can be successfully implemented, and the data modified in AP mode will be stored in the built-in...
e9996 stm32/stm8
Some shortcut keys of PROTEL
Some shortcut keys of PROTEL enter - select or start esc - give up or cancel f1 - start the online help window tab - start the property window of the floating drawing pgup - enlarge the window display...
设计狂人 FPGA/CPLD
About the problem of MSP430FR6972 bootloader address jumping to APP
Hello everyone! Can anyone with knowledge give me some advice? After I started the bootloader of MSP430FR6972, I downloaded the APP program to the designated area 5400-FF7F. The download was correct (...
chenjx_ortega Microcontroller MCU
Some basic issues of infrared communication
I plan to learn how to use a microcontroller to control infrared communication. The experiment book shows that the infrared transmitters TSAL6200 and HS0038 are used. I searched the data sheets of the...
zzwwjj Embedded System
EEWORLD University - PCB layout techniques for reducing radiated EMI in designs
PCB layout techniques for reducing radiated EMI in your design : https://training.eeworld.com.cn/course/630...
hi5 Talking
Please advise on the use of cadence simulation calculator
I used Cadence to simulate an amplifier circuit and then wanted to check the power amplification. I found a gp function in the calculator. Can I use this function to calculate it? But I have tried man...
romero Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 76  471  604  1591  631  2  10  13  33  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号