2200SAG60IPF3JB

Description
Strain Guage Sensor, Absolute, 0Psi Min, 600Psi Max, 0.15%, 0-10V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200SAG60IPF3JB Overview

Strain Guage Sensor, Absolute, 0Psi Min, 600Psi Max, 0.15%, 0-10V, Cylindrical

2200SAG60IPF3JB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Nominal offset0V
Maximum operating temperature50 °C
Minimum operating temperature-20 °C
Output range0-10V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type9/16 MALE
Maximum pressure range600 Psi
Minimum pressure range
Pressure sensing modeABSOLUTE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeMETAL CABLE GLAND
Base Number Matches1
57 things you should know when you are a DSP
Post a thread! I hope it will be useful to you all!...
wpdy DSP and ARM Processors
Bought TMS570
I bought a TMS570 and encountered a problem. Please give me some advice....
siyida_01 Microcontroller MCU
[Open Source] Design of FPGA-based serial multiplier
This time I will share with you two generations of serial multipliers. Serial multipliers are still used in some places where real-time requirements are not high, such as the calculation of DDS, frequ...
k331922164 FPGA/CPLD
Review summary: Anxinke NB-IoT development board EC-01F-Kit
Event details: [Anxinke NB-IoT development board EC-01F-Kit]Updated to 2021-12-11Evaluation report summary:@kit7828[Anxinke NB-IoT Development Board EC-01F-Kit] 1. Unboxing and Hardware Appreciation@秦...
EEWORLD社区 Special Edition for Assessment Centres
How does IAR compiler set a function in a source file to compile at the starting address?
How to set IAR compiler to compile a function of a source file at the starting addressI am using STM32 M3 chipFor exampleI want to compile the main function of main.c at the starting address.How shoul...
虾段 stm32/stm8
The positive and negative input terminals of the isolation op amp are connected to a solid-state relay respectively. I wonder if it will have any impact on the acquisition?
The positive and negative input terminals of the isolation op amp are respectively connected to a solid-state relay to control whether the signal to be collected is connected to the isolation op amp, ...
milan111 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2893  2380  2077  2708  295  59  48  42  55  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号