BR805
THRU
SINGLE-PHASE SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 8.0 Amperes
FEATURES
* Surge overload rating: 200 amperes peak
* Low forward voltage drop
BR810
MECHANICAL DATA
*
*
*
*
*
*
UL listed the recognized component directory, file #E94233
Epoxy: Device has UL flammability classification 94V-O
Lead: Mil-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 7.86 grams
Mounting: Hole thru for # 6 screw
.052 (1.3)
.048 (1.2)
BR-8
.295(7.63)
.245(6.35)
.75
(19.1)
MIN.
.158 (4.0)
.154 (3.9)
AC
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.520 (13.21)
.480 (12.19)
o
AC
.520 (13.21)
.480 (12.19)
.770 (19.558)
.730 (18.542)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS
(At T
A
= 25 C unless otherwise noted)
o
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Tc = 50 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
o
SYMBOL
V
RRM
V
RMS
V
DC
I
O
I
FSM
BR805
50
35
50
BR81
100
70
100
BR82
200
140
200
BR84
400
280
400
8.0
125
65
BR86
600
420
600
BR88
800
560
800
BR810
1000
700
1000
UNITS
Volts
Volts
Volts
Amps
Amps
Operating Temperature Range
Storage Temperature Range
ELECTRICAL CHARACTERISTICS
(At T
A
= 25 C unless otherwise noted)
o
T
J
T
STG
-55 to + 150
-55 to + 150
0
0
C
C
CHARACTERISTICS
Maximum Forward Voltage Drop per element at 4.0A DC
Maximum Reverse Current at Rated
DC Blocking Voltage per element
@T
A
= 25 C
@T
C
= 100 C
o
o
SYMBOL
V
F
I
R
BR805
BR81
BR82
BR84
1.1
5.0
0.2
BR86
BR88
BR810
UNITS
Volts
uAmps
mAmps
2014-08
REV: A
NOTES : 1. Thermal Resistance : Mounted on PCB.
2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
3. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
RATING AND CHARACTERISTIC CURVES ( BR805 THRU BR810 )
FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
PEAK FORWARD SURGE CURRENT, (A)
FIG. 2 - TYPICAL FORWARD CURRENT
DERATING CURVE
AVERAGE FORWARD CURRENT, (A)
250
8.3ms Single Half Sine-Wave
(JEDEC Method)
10
8
CAS
E
200
150
6
100
4
60 Hz RESISTIVE OR
INDUCTIVE LOAD
50
2
0
0
1
2
4 6 8 10
20
40 6080100
NUMBER OF CYCLES AT 60Hz
0
50
100
CASE TEMPERATURE, (
150
)
FIG. 3- TYPICAL INSTANTANEOUS FORWARD
FIG. 4- TYPICAL REVERSE
CHARACTERISTICS
CHARACTERISTICS
INSTANTANEOUS FORWARD CURRENT, (A)
100
TJ = 25
Pulse Width = 300us
1% Duty Cycle
INSTANTANEOUS REVERSE CURRENT, (uA)
1000
10
100
T
A
= 125 C
O
1.0
10
.1
1
T
A
= 25 C
O
0.1
0
20
40
60
80
100
120
140
.01
0
.5
1.0
1.5
2.0
2.5
3.0
3.5
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
INSTANTANEOUS FORWARD VOLTAGE, (V)
RECTRON
RECTRON
Attachment information about BR8X
1.
Internal Circuit
2. Marking on the body
Rectron Logo
Plant - code
UL Logo
Year – code
(Y: Last digit of year &
A:2010, B:2011……)
BR8
VXXX
Part No.
Week – code
(WW:01~52)
3. Items marked on the inner box and carton
3.1 On the box (for –B)
CUSTOMER
TYPE
LOT NO.
QUANTITY
Q.A.
DATE
3.2 On the carton
CUSTOMER
TYPE
QUANTITY
LOT NO.
REMARK
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
BR-8/-10
PACKING CODE
-B
EA PER BOX
200
INNER BOX SIZE
(mm)
236*236*50
CARTON SIZE
(mm)
497*251*282
EA PER CARTON
1,600
GROSS
WEIGHT(Kg)
9.80
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.