0215008.

Description
Axial Lead and Cartridge Fuses - Designed to IEC Standard
File Size79KB,1 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet View All

0215008. Overview

Axial Lead and Cartridge Fuses - Designed to IEC Standard

Axial Lead and Cartridge Fuses
Designed to IEC Standard
5 x 20 mm
Time Lag Fuse (Slo-Blo
®
Fuse) 215 Series
®
®
D
V
E
• Designed to International (IEC) Standards for use globally.
• Meets the IEC 60127-2, Sheet 5 specification for Time Lag Fuses.
• Available in Cartridge and Axial Lead Form.
• Available in ratings of .2 to 12 amperes.
• High breaking capacity.
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
150%
210%
275%
Ampere
Rating
.1-6.3
8-12
.1-12
.1-.8
1-12
.1-.8
1– 3.15
4– 6.3
.1-.8
1-12
Opening
Time
60 minutes,
Minimum
30 minutes,
Minimum
30 minutes,
Maximum
.25 sec.,
Min.;
80 sec.
Max.
.75 sec.,
Min.;
80 sec.
Max.
.05 sec.,
Min.;
5 sec.
Max.
.095 sec.,
Min.;
5 sec.
Max.
.150 sec.,
Min.;
5 sec.
Max.
.005 sec.,
Min.;
.15 sec.,
Max.
.010 sec.,
Min.;
.15 sec.,
Max.
5.2
(.205")
400%
215 000
215 000 XE
.65*
(.026")
1000%
AGENCY APPROVALS:
Sheet V IEC 60127-2:* SEMKO approved 1A-6.3A.
BSI approved 1-6.3A. VDE approved 1A-12A. METI approved 1-12A. Recognized
under the Components Program of Underwriters Laboratories and recognized by
CSA from 0.5A-12A. K Mark approved 1A-12A.
INTERRUPTING RATING:
1500 amperes @ 250VAC, 0.7-0.8 power factor.
ORDERING INFORMATION:
20
(.787)
6.0 MAX
(.236")
22.5 MAX
(.886)
40
(1.58)
*Ratings above 6.3A
have 0.8 dia lead
Average Time Current Curves
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A
8A
10A
12A
100
Cartridge
Catalog
Number
215.200
215.250
215.315
215.400
215.500
215.630
215.800
215
001
215
1.25
215
01.6
215
002
215
02.5
215
3.15
215
004
215
005
215
06.3
215
008
215
010
215
012
Ampere
Rating
.200*
.250*
.315*
.400*
.500*
.630*
.800*
1
1.25
1.6
2
2.5
3.15
4
5
6.3
8*
10*
12*
Voltage
Rating
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Nominal
Resistance
Cold Ohms
1.750
1.170
0.873
0.560
1.080
0.660
0.436
0.110
0.085
0.0588
0.043
0.0312
0.0220
0.0163
0.0125
0.0099
0.0078
0.0060
0.0055
Nominal
Melting I
2
t
A
2
Sec.
0.37
0.56
1.08
1.45
0.34
0.56
0.954
1.05
2.05
3.90
6.95
10.65
21.2
38.7
82.85
132.5
209.5
360.5
515.0
10
TIME IN SECONDS
1
11
AXIAL LEAD AND
CARTRIDGE FUSES
1
10
CURRENT IN AMPERES
100
500
0.1
0.01
*IEC Standards for 5 x 20mm fuses do not include ratings above
6.3 amperes, but are under consideration.
IEC 60127-2, Sheet 5 does not include ratings below 1 ampere (under
consideration by IEC).
0.001
0.05 0.1
w w w. l i t t e l f u s e . c o m
403
Looking for digital 2.4G wireless communication?
Does anyone have any information about digital 2.4G wireless communication? Please share, I will be very grateful! ! ! ! !...
NiNoLAM RF/Wirelessly
Are these the reasons why surge testing always burns out amplifier boards?
When doing surge test on the equipment, other parts were not damaged. Why was only the power amplifier board farthest from the power input terminal burned? The equipment layout diagram is as followsBe...
qwqwqw2088 Analogue and Mixed Signal
Memory Type
I recently encountered some problems with memory types, and the following information is summarized:code Program space (64K bytes) MOVC @A+DPTR access data (00H~7FH) Directly access internal data memo...
nicole088 FPGA/CPLD
Do ZLG's USBCAN and Ethernet cards support C++ and C#?
[color=#333333][font=Arial, Helvetica, sans-serif][size=12px]Do ZLG's USBCAN and Ethernet cards support C++ and C#? [/size][/font][/color]...
喜鹊王子 TI Technology Forum
Master-slave station program when two PLCs are connected using an N:N network
I would like to ask the master and slave station program when connecting two PLCs in N:N mode. The program written according to the tutorial has problems, and the two PLCs cannot communicate normally....
总是说太多 Integrated technical exchanges
Brief introduction to hearing aid instructions and usage recommendations
Brief introduction to hearing aid instructions and usage recommendations   The application of electronic technology in the medical field has brought revolutionary development to medical technology. As...
sairvee Medical Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1338  1447  1410  2800  2057  27  30  29  57  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号