外½寸法 EXTERNAL
DIMENSIONS
Type
リード線
Lead type
AG15
Kフォーミング Formed
K2M,K2U,K4M,K4U
ストレート
Straight
L3N
AG20
Hフォーミング Formed
H3D
キ
ャ
ッ
プ
レ
ス
Capless
本½の厚さ
Thickness of bodyD3.5max
f0.138maxg
本½の厚さ
Thickness of bodyD4M0.5
f0.157M0.020g
本½の厚さ
Thickness of bodyD4M0.5
f0.157M0.020g
8
SURGE ABSORBERS
キ
ャ
ッ
プ
付
き
Capped
E
本½の厚さ
Thickness of bodyD4M0.5
f0.157M0.020g
本½の厚さ
Thickness of bodyD4.7M0.5
f0.184M0.020g
本½の厚さ
Thickness of bodyD4.7M0.5
f0.184M0.020g
UnitDmmfinchg
アイテム一覧 PART
NUMBERS
EHS
½ 式
Type
(Environmental
Hazardous
Substances)
AG15PG⃝⃝⃝RG
E½½½
AG20PG⃝⃝⃝R
E½½½
RoHS
RoHS
放電開始電圧
Discharge starting voltage
fDCg
公称値
Nominal value[V]
1200 1500 2000
2500
1200 1500 2000
2500
許容差
M
500
M
800
M
500
M
800
絶縁抵抗
Insulation
resistance
リード½状
Lead configuration
Tolerance[V]
[ME]I1
10000min
10000min
Kフォーミング K Formed
ス レ ト
Hフ
ー ン
ト ー 、 ォ ミ グ
Straight ,H Formed
½名のGには被覆状態、⃝には放電開始電圧、Rには許容差、☆には包装、½にはリード½状記号が入ります。
GPlease
specify the coating condition code and
Z
the discharge starting voltage code and
R
the tolerance code and
G
the packaging code and
½
the
lead configuration code.
f注g½用している材料は自己消火性樹脂で、UL94V-0、UL1410fphase
ll
規制gを保証するものです。
NoteDThe material used is a self-extinguishing resin conforming to UL94V-0 and UL1410fphase ll regulationg
I1
AG15、AG20はDC500V20秒以内の値です。
I1
Values of AG15,AG20 are set at DC500V within 20 seconds.
セレクションガイド
Selection Guide
アイテム一覧
Part Numbers
特性図
Electrical Characteristics
梱包
Packaging
信頼性
Reliability Data
½用上の注意
Precautions
P.14
etc
P.481
P.482
P.483
P.484
P.486
481
RELIABILITY DATA
SPARK GAPS
Item
Specified Value
Test Methods and Remarks
1.Operating Temperature
Range
K30CVJ85C
2.Operating Humidity Range
95%RH max.
fNo
dew condensationg
3.Storage Temperature
Range
4.Discharge Voltage
K40CVJ85C
Within the specified tolerance
With the Circuit 1 shown below, conduct measure-
ment with voltage application.
5.Insulation Resistance
10,000 ME min.
Applied voltageD500VDC
DurationDWithin 20 sec.
6.Capacitance
1pFmax.
Measuring frequencyD1M0.1MHz
Measuring voltageD0.5V5.0Vrms
Bias applicationDNone
8
SURGE ABSORBERS
7.Discharge
Life
Discharge
Voltage
Change
Insulation
Resistance
8.Damp Heat
Discharge
Voltage
Change
Insulation
Resistance
9.Terminal
Strength
Tensile
5000ME
No damage
J50
L
K30
J20
K35
L
With the Circuit 2 shown below, repeat discharge
with specified voltage, followed by the measurement
within 2 to 5 hrs.
Number of dischargeD10,000 times
5000ME
TemperatureD40M2C
HumidityD90V95LRH
DurationD250 hrs
RecoveryD2 to 5 hrs of recovery under the standard
condition after the removal from test chamber.
Apply the tensile force in the direction to draw terminal.
Applied forceD9.8N
No damage
Torsional
Apply the bending force to incline the body to right and left
through angle of 90°
Applied forceD4.9N
Circuit 1
Circuit 2
AG15、AG20
RD20ME
CD2000pF
AG15、AG20
RD20ME
CD10000pF
EDRefer to individual specification
Note on standard condition: "standard condition" referred to herein is defined as follows:
5 to 35C of temperature, 45 to 85% relative humidity and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20M2C
of temperature, 60 to 70% relative humidity and 86 to 106kPa of air pressure.
Unless otherwise specified, all the tests are conducted under the "standard condition."
485