L11-B1-44-410-24A-DG

Description
Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size2MB,8 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

L11-B1-44-410-24A-DG Overview

Magnetic Circuit Breaker,

L11-B1-44-410-24A-DG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompli
Circuit protection typeMAGNETIC CIRCUIT BREAKER
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
Is there any good way to prevent or cure pollen allergy?
It is the season of spring when everything comes back to life and flowers bloom. It is a good time to go to the park for fun. However, for those who are allergic to pollen, there are many troubles.Sne...
eric_wang Talking
Urgent, urgent, urgent, urgent
What is the reason? I can't open the project. It's urgent. Please help me :Sad:...
曹伟1993 TI Technology Forum
【TI's First Low Power Design Competition】GSM SMS Test
[i=s]This post was last edited by tianshuihu on 2015-1-8 00:47[/i] GPS positioning can only obtain information about the current location. If the information cannot be uploaded, its application will b...
tianshuihu Microcontroller MCU
712 main frequency time problem, why interrupt processing time has not improved
The size of the external interrupt handler is more than 100 assembly instructions. In order to ensure the shortest interrupt processing time, 48 MHz main frequency is used, but it still takes a lot of...
小庞 stm32/stm8
Can UART5 of STM32F103VCT6 use DMA?
As the title says, UART1-4 all have corresponding DMA channels, but UART5 does not have one. So I'm wondering if it's missing from the manual or if it just doesn't exist?...
qqq147258 stm32/stm8
Design Technology of Single-Chip Computer Power Supply
Abstract: This paper introduces the design ideas and methods of system power supply based on M6800 series microcontrollers, as well as the methods to eliminate the power frequency interference which h...
zbz0529 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1746  640  685  2043  1614  36  13  14  42  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号