EEWORLDEEWORLDEEWORLD

Part Number

Search

LBPM-112127331

Description
Fiber Optic Device
CategoryWireless rf/communication    Optical fiber   
File Size327KB,3 Pages
ManufacturerLaser Components USA Inc.
Download Datasheet Parametric View All

LBPM-112127331 Overview

Fiber Optic Device

LBPM-112127331 Parametric

Parameter NameAttribute value
MakerLaser Components USA Inc.
Reach Compliance Codeunknow
body width26 mm
body height8.2 mm
Body length or diameter36 mm
Crosstalk55 dB
Fiber optic equipment typesSWITCH
Fiber typePMF
Maximum insertion loss0.8 dB
Installation featuresTHROUGH HOLE MOUNT
Maximum operating temperature70 °C
Minimum operating temperature-5 °C
Maximum optical input power500 mW
optical life10000000 Cycle(s)
Port configuration1X1
minimum return loss55 dB
surface mountNO
Switch actionLATCHING
switching speed4 ms
LightBend
TM
1x1, 1x2 PM
OptoMechanical Fiberoptic Switch
(Protected by U.S. patent 6823102 and pending patents)
Product Description
The LB series 1x2 PM fiber optic switch has a polarization-maintaining fiber switch,
which connects optical channels by directing or blocking an incoming optical signal
into the output fiber. This is achieved using a patent pending opto-machnical
configuration and achieved via an electrical control signal. A latching version
preserves the selected optical path after the drive signal has been removed, while the
non-latching version defaults to either the open or close state when power is removed.
The switches integrated electrical position sensors. The new material-based advanced
design significantly reduces moving part position sensitivity, offering unprecedented
high stability as well as an unmatched low cost. Electronic driver is available for this
series of switches.
Features
Low Optical Distortions
High Isolation
High Reliability
Fail-Safe Latching
Epoxy-Free Optical Path
Performance Specification
LB Series 1x1, 1x2 PM Switch
Operation Wavelength
Insertion Loss
*
Wavelength Dependent Loss
Temperature Dependent Loss
Extinction Dependent Loss
Return Loss ¹
²
Cross Talk ¹
Switching Time
Repeatability
Min
850
Typical
1310, 1550
0.5
Max
0.8
0.15
±0.15
Unit
nm
dB
dB
dB
dB
dB
dB
ms
dB
Cycle
VDC
mA
ms
C
mW
o
C
mm
o
18
55
55
4
10
±0.02
Applications
Fault Protection
Channel Add/Drop
Channel Switching
Instrumentation
Durability
10
7
Operating Voltage
5
5
7
Operating Current
(Latching/Non-Latching)
30
60
Voltage Pulse Width
(Latching)
20
Switching Type
Latching / Non Latching
Operating Temperature
-5
70
Optical Power Handling
300
500
Storage Temperature
-40
85
Package Dimension
36.0L x 26.0W x 8.2H
Note:
1. Exclude connectors, IL≤1.0dB for Dual and Broad Band.
2. Within operating temperature and SOP.
LASER COMPONENTS GmbH
Werner-von-Siemens-Str. 15, 82140 Olching, Germany, Phone: +49 8142 2864 0, Fax: +49 8142 2864 11, info@lasercomponents.com
Classification and application of switching power supply
With the rapid development of power electronics technology, the relationship between power electronics equipment and people's work and life is becoming increasingly close, and electronic equipment can...
zbz0529 Power technology
MSP-GANG430 readable file types
I wrote .S43 in FET and now want to use it in MSP-GANG430. But the latter only accepts .txt and .A43 files. What should I do? Is there any way to convert .S43 files into .A43 files? Please help me!...
mfsmfs Microcontroller MCU
C8051f040 novice asks
I just started to learn c8051f040, I want to know, how to burn the program into the 040 chip, I have an emulator, but I don't know how to use it, and what the programmer is used for, can an expert tel...
kjpioo Embedded System
System performance indicators of single-phase sine wave inverter
What are the system performance indicators of a single-phase sine wave inverter? Is maximum distortion = harmonic content = THD? Can waveform distortion be seen on a power factor analyzer? What is the...
这题我不会 Analog electronics
PADS PCB board partial circuit replication
When drawing with PADS, you will often encounter such a requirement, that is, copy part of the circuit of a PCB board to another board. Usually there are the following methods: 1. After clicking ECO o...
ohahaha PCB Design
Using CCS to develop code structure, power-on loading and online programming of DSP applications
1. There are three types of DSP application code structures: ○ Pure assembly; ○ Pure C language; ○ Assembly + C language. These three structures can also be inserted with DSP/BIOS API with or without ...
Aguilera Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1930  822  1593  1500  688  39  17  33  31  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号