Wire And Cable, 1 Conductor(s), 26AWG, 600V, Flexible Cord And Fixture Wire
CategoryThe connector    Connector bracket   
File Size72KB,1 Pages
ManufacturerHabia Cable
Environmental Compliance
Download Datasheet Parametric View All

412222619 Overview

Wire And Cable, 1 Conductor(s), 26AWG, 600V, Flexible Cord And Fixture Wire

412222619 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerHabia Cable
Reach Compliance Codeunknow
Other featuresSTANDARD: NEMA HP-3
applicationGAS IGNITION, GAS TURBINE, VACUUM, HIGH TEMPERATURE DATA
CertificationNEMA
Conductor surface treatmentNICKEL
conductor materialCOPPER
Connector bracket typeWIRE AND CABLE
structureSTRANDED
Cross-sectional area0.16 mm2
diameter1 mm
insulator materialPTFE
Number of conductors1
Maximum operating temperature260 °C
Minimum operating temperature-65 °C
Rated current9 A
Rated voltage600 V
resistance0.135 Ω
shieldNO
stay19X0.102
Wire gauge26 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
E
(PTFE)
Construction
SPC
NPC
-65
o
C to +200
o
C
-65
o
C to +260
o
C
0.6/1kV AC U
0
/U
3.4kV AC
Conductor
Shield
E
E NPC
-
Silver Plated Copper (SPC)
Nickel Plated Copper (NPC)
600V
-65
o
C/+200
o
C and +260
o
C
Insulation
Sheath
PTFE
-
Single core
Temp.
Voltage
Test voltage
Flame retardant
Low smoke generation
NEMA HP-3
Application
PTFE is Habia Cable’s foremost insulation material, intended for use up to 260
o
C. PTFE has excellent mechanical
properties, including solder resistance and offers unparalleled electrical performance. Typical applications for PTFE
include gas ignition wires, gas turbines, vacuum applications and high temperature data cables. Cores are designed
according to NEMA HP-3.
Description
AWG
E 3201
E 3201 NPC
E 3207
E 3207 NPC
E 3001
E 3001 NPC
E 3007
E 3007 NPC
E 2801
E 2801 NPC
E 2807
E 2807 NPC
E 2601
E 2601 NPC
E 2607
E 2607 NPC
E 2619
E 2619 NPC
E 2401
E 2401 NPC
E 2407
E 2407 NPC
E 2419
E 2419 NPC
E 2201
E 2201 NPC
E 2207
E 2207 NPC
E 2219
E 2219 NPC
E 2001
E 2001 NPC
E 2007
E 2007 NPC
E 2019
E 2019 NPC
E 1801
E 1801 NPC
E 1807
E 1807 NPC
E 1819
E 1819 NPC
E 1601
E 1601 NPC
E 1619
E 1619 NPC
E 1419
E 1419 NPC
E 1219
E 1219 NPC
E 1237
E 1237 NPC
32
32
30
30
28
28
26
26
26
24
24
24
22
22
22
20
20
20
18
18
18
16
16
14
12
12
Size
CSA
mm
2
0.03
0.04
0.05
0.06
0.08
0.09
0.13
0.14
0.16
0.20
0.22
0.24
0.32
0.36
0.38
0.52
0.56
0.60
0.82
0.88
0.96
1.30
1.23
1.87
3.02
2.98
14
15
16
17
18
A1
A2
Conductor
resistance
stranding
Ω/km
544.60
1 x 0.203
580.70
557.70
7 x 0.079
610.20
347.80
1 x 0.254
360.90
328.10
7 x 0.102
360.90
218.80
1 x 0.320
227.70
208.70
7 x 0.127
221.80
137.50
1 x 0.404
143.00
130.20
7 x 0.160
138.50
122.40
19 x 0.102
134.50
86.00
1 x 0.511
89.60
80.40
7 x 0.203
85.30
77.40
19 x 0.127
82.70
54.10
1 x 0.643
56.40
51.20
7 x 0.254
53.10
48.60
19 x 0.160
51.50
33.80
1 x 0.813
35.40
32.20
7 x 0.320
33.50
29.90
19 x 0.203
31.80
21.40
1 x 1.024
22.30
20.20
7 x 0.404
21.10
19.00
19 x 0.254
19.80
13.40
1 x 1.287
14.00
14.90
19 x 0.287
15.50
9.42
19 x 0.361
9.81
5.94
19 x 0.455
6.17
6.20
37 x 0.320
6.46
wire
Ø
0.20
0.24
0.25
0.30
0.32
0.38
0.40
0.48
0.48
0.51
0.60
0.60
0.64
0.76
0.76
0.81
0.96
0.96
1.02
1.21
1.20
1.29
1.36
1.70
2.14
2.24
Finished Wire
core
tolerance
Ø
0.74
0.76
0.76
0.81
0.84
0.89
0.91
0.99
1.00
1.02
1.12
1.13
1.15
1.27
1.30
1.32
1.47
1.47
1.54
1.75
1.75
1.87
2.03
2.42
2.90
2.85
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
±0.10
weight
g/m
1.10
1.20
1.30
1.50
1.70
2.00
2.30
2.70
2.80
3.10
3.70
3.90
4.40
5.20
5.50
6.50
7.50
8.10
9.60
12.00
12.00
15.00
16.00
23.00
33.00
41.50
Electrical
amps at
40
o
C
3
4
3
4
4
5
4
5
6
7
6
7
8
9
8
9
8
9
10
12
10
12
10
12
14
16
14
16
14
16
19
22
19
22
19
22
27
30
27
30
27
30
32
36
32
36
43
50
59
67
59
67
Article Number
512cc3201
412cc3201
512cc3207
412cc3207
512cc3001
412cc3001
512cc3007
412cc3007
512cc2801
412cc2801
512cc2807
412cc2807
512cc2601
412cc2601
512cc2607
412cc2607
512cc2619
412cc2619
512cc2401
412cc2401
512cc2407
412cc2407
512cc2419
412cc2419
512cc2201
412cc2201
512cc2207
412cc2207
512cc2219
412cc2219
512cc2001
412cc2001
512cc2007
412cc2007
512cc2019
412cc2019
512cc1801
412cc1801
512cc1807
412cc1807
512cc1819
412cc1819
512cc1601
412cc1601
512cc1619
412cc1619
512cc1419
412cc1419
512cc1219
412cc1219
512cc1237
412cc1237
Single Wires
00 Black
11 Brown
22 Red
33 Orange
Available colours (replace ‘cc’ in the order reference)
44 Yellow
55 Green
66 Blue
77 Violet
88 Grey
99 White
29 Pink
89 Natural
45 Yel/Grn
Ref: EQ_E_12 Created: CJV Approved: AE Date: 2013-09-12
Data indicates nominal values unless stated otherwise, is only valid for reference purposes at the time of publication and is subject to change without prior notice.
14/28
www.habia.com
[You ask me an answer] A novice asks a question about the conduction voltage drop of a triode
The book says that the voltage drop of the emitter junction of a silicon triode is about 0.7V. Why is it this value? How did this value come from?...
桂花蒸 Analog electronics
Experts who have designed optical transceivers or worked on optical fiber transmission systems are welcome to come in
I would like to ask about the details of the optical transceiver! QQ: 552112190...
s110400710 Embedded System
Excuse me, which microcontroller has better encryption performance now?
I would like to ask, which MCU or ARM has better encryption performance? It is best that it cannot be easily cracked by others. Let's discuss it together, thank you....
njlianjian MCU
Looking for a source code of C voice under Linux, which can read various properties of PCI devices
I need a source code of C language in Linux, which can read various properties of PCI device. It is needed urgently!...
123 Linux and Android
Brief analysis of three detection methods for faulty cables
[size=4] The initial detection method of the faulty cable is divided into the loop bridge balance method, the low-voltage pulse reflection method, and the flash tester method. In the cable fault initi...
fish001 Analogue and Mixed Signal
Help, I am trying to control colored lights with IAR, but I cannot call library functions
I can't call the library function of 430f249. Once I call it, there are 100 errors. This is the program. Once compiled, a new window will pop up, and then there will be a bunch of errors #include #inc...
王大明丶 Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2317  1267  2757  1996  455  47  26  56  41  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号