EEWORLDEEWORLDEEWORLD

Part Number

Search

55.13.9.110.5091

Description
Electromechanical Relay, 3PDT-CO, MBB, 121VDC (Coil), 1W@110VDCmW (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.13.9.110.5091 Overview

Electromechanical Relay, 3PDT-CO, MBB, 121VDC (Coil), 1W@110VDCmW (Coil), Random, AC/DC Output

55.13.9.110.5091 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompli
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (DC)88 V
Coil power1000 mW
Coil resistance12500 Ω
Maximum coil voltage (DC)121 V
Nominal coil voltage110 V
Coil/Input Power TypeDC
Contact (AC) maximum rated power R load2500VA@400VAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life200000 Cycle(s)
End contact materialSILVER NICKEL
End contact platingGold
Input switching control typeRandom
Number of terminals11
operating hours10 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count11
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style3 FORM C
Relay function3PDT-CO
release time5 ms
Terminal length0.0048 inch
Termination typeSOLDER
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
What is considered a high salary?
Annual salary, monthly salary? Food included? Housing included? Subsidies? How do you calculate what is considered a high salary when you have all these things? For example, 5,000 a month, no overtime...
sadlife1000 Talking
Safety emergency lights
:loveliness:...
shenjimin DIY/Open Source Hardware
Some considerations for DSP hardware design
Principles for selecting clock circuits1. When multiple clock signals of different frequencies are required in the system, programmable clock chips are preferred;2. When a single clock signal is used,...
灞波儿奔 Microcontroller MCU
STM32 interrupt priority group I didn't understand this table before, now I finally understand it, I hope the experts can confirm it
I used to find the following table difficult to understand, but today I feel like I finally understand it. This table should be read horizontally. If it is set to group 0, then the maximum priority le...
yuke30 stm32/stm8
Has anyone encountered the problem of access concentrator not responding when using PPPOE under WINCE5.0?
My initial judgment is that the PPPOE.LIB implementation is not flexible enough. The order of SERVICE-NAME and the length of AC-NAME, etc., will cause the WINCE PPPOE protocol stack to be unresponsive...
longyiquan Embedded System
MPU6050 anonymous host computer code request
[b][color=#cc00][size=3]I want to learn about the host computer. I have an MPU6050. Can anyone who has the [url=http://www.baidu.com/link?url=YWixM5Epx0upWMnguVI65X-lCEDr8BC3UFajkE-n1jfe2Ny80JEJT8qgZN...
wsyyj Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2876  327  2376  2902  53  58  7  48  59  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号