MMSI-01R-21K2-006-1810 Overview

Telecom and Datacom Connector, 23 Contact(s), Female, Wire Terminal, Locking, Receptacle

MMSI-01R-21K2-006-1810 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAirBorn
Reach Compliance Codecompli
ECCN codeEAR99
body width0.481 inch
subject depth1.055 inch
body length1.636 inch
Body/casing typeRECEPTACLE
Connector typeTELECOM AND DATACOM CONNECTOR
Contact to complete cooperationNICKEL
Contact completed and terminatedTIN SILVER COPPER
Contact point genderFEMALE
Contact materialBRASS
contact modeSTAGGERED
maximum insertion force1.668 N
Insulation resistance5000000000 Ω
insulator materialGLASS FILLED LIQUID CRYSTAL POLYMER
JESD-609 codee1
Manufacturer's serial numberMMSI
Plug contact pitch0.07 inch
Match contact row spacing0.08 inch
Installation option 1LOCKING
Installation option 2LOCKNUT
Installation typeCABLE
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Plating thickness50u inch
Rated current (signal)3 A
reliabilityCOMMERCIAL
Shell surfaceELECTROLESS NICKEL
Shell materialALUMINUM ALLOY
Termination typeWIRE
Total number of contacts23
Maximum wire diameter28 AWG
Minimum wire diameter28 AWG
Evacuation force-minimum value.139 N
CALL 512-863-5585
x6464
DIMENSIONS
MMSI – Cable I/O (Female)
CONTACT CUSTOMER SERVICE
MMSI cable connectors are used in cable
applications where signal integrity is desired. The
connector interface controls the polarization of
the twinax contact style. Comes with a variety of
wiring and hardware options. All cable connectors
are available in custom lengths.
ORDER FORM
ENTER
CODE
ENTER
CODE
ENTER
CODE
Sample Part Number Format: MMSI-XXX-XXXX-XXX-XXXX
ENTER
CODE
ENTER
CODE
ENTER
CODE
ENTER
CODE
MMSI
SERIES
Cable I/O
(Female)
1.78 mm
STYLE
21 – Female, Twinax
100Ω 24 AWG
24 – Female, Twinax
100Ω 30 AWG
WIRE LENGTH
1
Inches, 3 digits
Ex. 018 = 18 inches
HARDWARE
620 – Fixed Jacknuts
810 – Turning Jackscrews
Captivated**
NXX – Keying Jacknuts***
JXX – Keying Jackscrews***
BODY PLATING, INTERNAL SOLDER
1 – Electroless Nickel, SAC305
2 – Electroless Nickel, Sn/Pb
S
5 – Gold, SAC305
6 – Gold, Sn/Pb
S
SIZE & INTERFACE POLARIZATION*
01L – 1X Left (23 pins, 4 DP +9SB)
01R – 1X Right (23 pins, 4 DP +9SB)
04L – 4X Left (41 pins, 10 DP +9SB)
04R – 4X Right (41 pins, 10 DP +9SB)
08L – 8X Left (65 pins, 18 DP +9SB)
08R – 8X Right (65 pins, 18 DP +9SB)
OVERALL****
0 – None
1 – Silver-Plated Braid
2 – Tin-Plated Braid
3 – Silver-Plated Braid, Halar® Sleeving
4 – Tin-Plated Braid, Halar® Sleeving
5 – Halar® Sleeving (no braid)
High-Reliability
Contact
MIL-DTL-83513
SIDEBAND WIRES
(color code per MIL-STD-681)
A – 22759/11-24
B – 22759/11-26
C – 22759/11-28
D – 22759/33-24
S
E – 22759/33-26
S
F – 22759/33-28
S
G – 22759/33-30
S
H – NEMA HP3-EXBEB 24 AWG
J – NEMA HP3-EXBDB 26 AWG
K – NEMA HP3-EXBCB 28 AWG
L – NEMA HP3-EXBBB 30 AWG
NOTES
1.
2.
Overall braid and/or Halar® will be 1.0 ± 0.5 inches shorter than specified wire length.
Minimum length without overall braid or Halar® is 3 inches. If overall braid or Halar® is
specified the minimum length is 6 inches.
All microSI females have fluorosilicone interfacial seals installed.
Option not RoHS compliant
Left or right polarization is determined by looking at the male interface with the LONG
SIDE downward. Polarization matches the angled side. Sidebands are on the non-angled
side.
Captivated hardware is factory-installed and non-removable.
Factory-installed and non-removable.
Halar is a registered trademark of Ausimont.
MATERIALS & FINISHES
S
*
**
***
****
Socket Contact: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Pin Contacts: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BeCu alloy strip
Contact Finish: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gold plate, 50 µ” minimum
Shells: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum alloy 6061-T6
Shell Finishes: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electroless nickel or gold
Molded Insulators: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glass-filled liquid crystal polymer (LCP)
Embedment: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frey Eng. Co. compound CF3003-80 & L-II-49
Hardware: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Corrosion-resistant steel
Interfacial Seal Gaskets: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fluorosilicone
EMI Gaskets: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Corrosion-resistant steel
NOTE: AirBorn can manufacture special configurations to your exact specifications.
SIGNAL INTEGRITY PERFORMANCE (Connectors Only)
REQUIREMENTS
ACTUAL
1
2
3
4
Diff. Impedance, filtered to 79 ps (20-80%)
Diff. Insertion Loss
Diff. Return Loss
Intra-Pair
100 ohm
10 GHz @ -3 dB
7.5 GHz @ -10 dB
< 2 ps
PERFORMANCE
Contact Rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 amperes maximum
Operating Temperature:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55° C to 125° C
Maximum Working Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200V, RMS, 60Hz
Insulation Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5,000 megohms minimum @ 500 VDC
Durability:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 connector mating cycles
Contact Engaging Force: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 ounces maximum/contact
Contact Separating Force:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 ounces minimum/contact
Mating & Unmating Force: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 ounces maximum/contact
NOTE: Performance values are estimates at this time. Actual values will be determined
when final product testing is complete.
PATENT PENDING
www.AIRBORN.com
( 512 ) 863-5585
PRELIMINARY RELEASE
2012-July-31
RF antenna in electronic tag
In RF devices, as the operating frequency increases into the microwave region, the matching problem between the antenna and the tag chip becomes more severe. The goal of the antenna is to transfer the...
JasonYoo RF/Wirelessly
Calculation/estimation of power at transformer output
The voltage of the power distribution system on board is 3-phase 480V 60hz with an error of plus or minus 10%, but the electrical appliance to be used has an input power of 6.7KW, 3X440V 60HZ, and the...
eeleader Industrial Control Electronics
Storage test HD tune
[i=s]This post was last edited by Bai Ding on 2016-7-22 23:27[/i] HD Tune Pro is a compact and easy-to-use hard disk tool software. Its main functions include hard disk transfer rate detection, health...
白丁 Integrated technical exchanges
MSP430 JTAG pin diagram
JTAG pin definition descriptionThe JTAG interface mainly includes 5 pins: TMS, TCK, TDI, TDO and an optional pin TRST. These pins are used to drive the circuit module and control the execution of spec...
火辣西米秀 Microcontroller MCU
How to use KEIL 5 to quickly build project templates for stm32f401 Necleo
[align=left] [font=宋体]I have been using Keil 5 for a while and found that it is very thoughtful and has a driver library ready for you. This new feature can save our time and allow beginners to get st...
ld056k stm32/stm8
How to end an arbitrary process under WIN CE
How to end an arbitrary process under WIN CE, for example, I want to end explorer.exe. I read a passage on the Internet: HWND hWnd; // First get the handle of the window you want to close// For exampl...
hanbin Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2064  1937  2570  1753  1804  42  39  52  36  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号