Series PCV
Analog Input Power Controller
•
•
•
•
Operates at 60Hz & 50Hz
Internal Snubber
Industry Standard Package
Control Circuit Requires No
Adjustment or Calibration
The PCV Series proportional controllers
are self contained power control mod-
ules integrating a complete phase fired
logic control system and a solid state
relay in the same standard package.
Typical applications include heaters,
vibratory feeders and tungsten lamps.
MODEL NUMBERS
7PCV2415 7PCV2425
10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490
100-240
.15-15
600
150
10
94
1.6
200
0.5
100-240
.15-25
600
250
15
260
1.6
200
0.5
7PCV24xx
2-7 Vdc
4 mA
100-240
.15-50
600
625
20
1620
1.6
200
0.5
100-240
.15-75
600
1000
20
4150
1.6
200
0.5
10PCV24xx
2-10 Vdc
4 mA
100-240
.15-90
600
1200
20
6000
1.6
200
0.5
OUTPUT SPECIFICATIONS
➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current Range [Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (1 Cycle) [Apk]
Max. Off-State Leakage Current @ Rated Voltage [mA]
Maximum I 2 t for Fusing (8.3 msec) [A 2sec]
Maximum Voltage Drop (100% On) [Vpk]
Minimum Off-State dv/dt [V/µsec]
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS
➀
Control Voltage Range
Typical Input Current @ 5 Vdc
GENERAL NOTES
© 2002 CRYDOM CORP, Specifications subject to change without notice.
➀
All parameters at 25º C unless otherwise specified.
Percentage ON
TYPICAL APPLICATIONS
•
Industrial Temperature Controllers
•
Light Dimming
•
Vibratory Feeders
•
Resistive Heating Elements
•
Conveyor Speed Control
UNSUITABLE APPLICATIONS
The PCV is not suitable for some load applications
including, but not limited to the following:
Percentage On vs. Input Voltage
100
80
60
40
50 Hz
Zero Crossing Applications
Please contact Crydom’s application
engineering department for additional
information and specific application
questions.
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 1 OF 2
•
•
•
•
AC Motor Control
Three Phase Motors
Transformers requiring pure sine wave input
20
0
2.5
3.5
4.5
5.5
6.5
7.5
60 Hz
8.5
9.5
Input Voltage
For recommended applications and more information contact:
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506
Series PCV
Analog Input Power Controller
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
Dielectric Strength, Signal to Base
Ambient Operating Temperature Range
Ambient Storage Temperature Range
M ECHANICAL SPECIFICATIONS
Weight: (typical)
2500 Vrms
2500 Vrms
-30 to 80˚C
-40 to 125˚C
3.5 oz. (100g)
Thermally Conductive Epoxy
Encapsulation:
Terminals:
W IRING DIAGRAM
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1.10
(27.9)
.45
(11.4)
Screws and Saddle Clamps Furnished, Unmounted
~
1 OUTPUT 2
PROPORTIONAL
CONTROLLER
8-32 TERMINAL
(2 PLACES )
All dimensions are in inches (millimeters)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
1
1.87
(47.5)
OUTPUT
2
SOLID-STATE RELAY
--
4
INPUT
+
3
2.30
(58.4)
1.70
(43.2)
4
3
BASE PLATE
.125 (3.2)
1.00
(25.4)
1.80
(45.7)
6-32 TERMINAL
(2 PLACES)
.78
(19.8)
.90
(22.9)
INPUT
--
+
15A
15
4˚C/W
Base Plate Temp [˚C]
25A
30
2˚C/W
95
1˚C/W
3˚C/W
Power Dissipation
Power Dissipation
2˚C/W
10
6˚C/W
NO HEATSINK
116
20
15
10
NO HEATSINK
110
5
120
5
124
0
3
6
9
12
15
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [˚C]
120
5
10
15
20
25
20
40
60
80
0
Load Current [Arms]
Max Ambient Temp. [˚C]
50A
60
1˚C/W
1.5˚C/W
.5˚C/W
75A
90
90
Base Plate Temp [˚C]
Base Plate Temp [˚C]
90A
120
.5˚C/W
.2˚C/W
.4˚C/W
90
Base Plate Temp [˚C]
95
Power Dissipation
.5˚C/W
.3˚C/W
Power Dissipation
40
2˚C/W
100
60
1˚C/W
100
Power Dissipation
80
1˚C/W
100
20
NO HEATSINK
110
30
110
110
40
120
0
20
40
60
80
0
20
40
60
80
120
0
80
15
30
45
60
75
20
40
60
80
120
0
10
20
30
40
50
20
40
60
Load Current [Arms]
Max Ambient Temp. [˚C]
Load Current [Arms]
Max Ambient Temp. [˚C]
Load Current [Arms]
Max Ambient Temp. [˚C]
©2002 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506
Base Plate Temp [˚C]
CURRENT DERATING CURVES
112
25
100