EEWORLDEEWORLDEEWORLD

Part Number

Search

121-101-2-2-16CTC

Description
Helical Convoluted Tubing
File Size326KB,1 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet View All

121-101-2-2-16CTC Overview

Helical Convoluted Tubing

Convoluted
Tubing
121-101
Series 74 Helical Convoluted Tubing (AMS-T-81914)
Type D: Convoluted Tubing with Single External Shield
A
Product Series
121
- Convoluted Tubing
Class
1
- Standard Wall
2
- Thin Wall
2
Tubing Size
(See
Table I)
Material
K
- PEEK
4
E
- ETFE
F
- FEP
P
- PFA
T
- PTFE
3
Series 74
TYPE
D
T
121
-
101
-
1
-
1
-
16
B
K
EXTERNAL
SHIELD
B
Basic Part
Number
Convolution
1
- Standard
2
- Close
Color
B
- Black
C
- Natural
Shield
A
- Composite AmberStrand
®
C
- Stainless Steel
N
- Nickel/Copper
S
- SnCuFe
T
- Tin/Copper
SHIELD
C
A DIA
TUBING
B DIA
D
LENGTH
(AS SPECIFIED IN FEET)
MINIMUM
BEND RADIUS
E
F
TABLE I: TUBING SIZE ORDER NUMBER AND DIMENSIONS
TUBING FRACTIONAL
A INSIDE
B DIA
MINIMUM
SIZE
SIZE REF
DIA MIN
MAX
BEND RADIUS
06
3/16
.181 (4.6)
.370 (9.4)
.50 (12.7)
09
9/32
.273 (6.9)
.464 (11.8)
.75 (19.1)
10
5/16
.306 (7.8)
.500 (12.7)
.75 (19.1)
12
3/8
.359 (9.1)
.560 (14.2)
.88 (22.4)
14
7/16
.427 (10.8)
.621 (15.8)
1.00 (25.4)
16
1/2
.480 (12.2)
.700 (17.8)
1.25 (31.8)
20
5/8
.603 (15.3)
.820 (20.8)
1.50 (38.1)
24
3/4
.725 (18.4)
.980 (24.9)
1.75 (44.5)
28
7/8
.860 (21.8)
1.123 (28.5)
1.88 (47.8)
32
1
.970 (24.6)
1.276 (32.4)
2.25 (57.2)
40
1 1/4
1.205 (30.6)
1.589 (40.4)
2.75 (69.9)
48
1 1/2
1.437 (36.5)
1.882 (47.8)
3.25 (82.6)
56
1 3/4
1.688 (42.9)
2.132 (54.2)
3.63 (92.2)
64
2
1.937 (49.2)
2.382 (60.5)
4.25 (108.0)
APPLICATION NOTES
1.
Metric dimensions (mm) are
in parentheses and are for
reference only.
Consult factory for thin-
wall, close convolution
combination.
For PTFE maximum lengths
- consult factory.
Consult factory for PEEK
TM
min/max dimensions.
2.
3.
4.
G
© 2009 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
C-10
Tft LCD screen does not display,
I bought a 3.5-inch tft LCD screen on Taobao. The main control of the screen is ili9481. Now it has been put aside for a long time. The program is burned into it with the emulator. It works normally! ...
xy598646744 MCU
RC charging calculation method
==S 投票==E 投票 S 文章(这部分加style只是为了看效果,基本上表现都受编辑器设置控制)RC charging calculation method Reprinted from: http://hi.baidu.com/cumtsun/blog/item/b8ee5f16561cae4e20a4e93c.htmlExample 1 : As shown in the figure, ...
安_然 Analog electronics
Relay drive problem. . Solution
Whether it is high or low, the relay will work. When it is high, the voltage difference between the 3rd and 4th pins of the optocoupler is 10V, and the relay is 24V. Shouldn't it be 0 when it is high?...
浅夏 Analog electronics
WinCE Bluetooth problem solved thanks
Hello everyone, I have a few questions to ask you. I am studying the Bluetooth device of embedded system recently. The CPU used is s3c2443, and the OS is WinCE Platform Builder 5.0. I want to build a ...
hongfs Embedded System
How to put constant array in code segment in ARM?
Now I have a large constant array const int testdata[1000]. In order to save memory, I want to put it in the code segment. How do I declare it? In the past, in the microcontroller, the bytes were simp...
dzzl ARM Technology
HPS-to-FPGA access to FPGA I/O
The problem of HPS accessing the i/o port of FPGA through the HPS-to-FPGA bridge. It is not a lightweight bridge. Has anyone done it before? I have been working on it for two days, but it doesn't work...
Makefile FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 705  1435  1421  2021  1910  15  29  41  39  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号