Pacific Scientific 6382 Rose Lane Carpinteria, CA 93013
Cage 02101 Tel 805.576.5000 Fax 805.576.5020
P
a
CIFIC SCIE
n
TIFIC
Electro Kinetics Division
www.psekd.com
Technical Data
SURGE ARRESTER
MODEL 2301-08-B
AND
2301-08-C
120 Vac or 24 Vdc
•
•
Application - Lightning and general purpose surge protection
for power circuits on aircraft and ground support equipment.
Application References
2301-08-B Replaces Model 2301-08 in older applications other than F-15
Cage 80063 / A3145328
2301-08-C NSN 5920-01-350-1256
Cage 76301 / ST5M1328-002; Cage 26512 / NGA817L
2301-08-C has a high strength Be-Cu housing for extreme vibration environments
•
•
•
•
•
•
•
•
Nominal System Voltage Rating
Maximum Continuous Operating Voltage
Source Impedance
System Frequency Rating
DC Sparkover
Insulation Resistance
Capacitance
Impulse Sparkover
100 V/s
50 Vdc
1 kHz
10 V/µs
100 V/µs
1 kV/µs
10 kV/µs
1.5 kA, 8/20
µs
3 kA, 8/20
µs
5 kA, 8/20
µs
15 kA, 8/20
µs
3 kA, 8/20
µs
120 Vac
132 Vac
<50 kVA
24 Vdc
28 Vdc
unlimited
DC - 400 Hz
350 - 450 V
>10
9
Ω
<12 pF
<500
<650
<750
<1000
<500
<1000
<1800
<5000
V
V
V
V
V
V
V
V
•
Discharge Voltage
•
•
•
•
•
Surge Life
Operating Temperature
Operating Altitude
Weight
Symbol
>100 times
-55 to +70 C
<25,000 m
75 g
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
TDS230108BC(k)