EEWORLDEEWORLDEEWORLD

Part Number

Search

RSB6SM27200415

Description
Barrier Strip Terminal Block, 20A, 1 Row(s), 1 Deck(s)
CategoryThe connector   
File Size163KB,4 Pages
ManufacturerThomas & Betts Corporation
Websitehttp://www.tnb.com/
Download Datasheet Parametric View All

RSB6SM27200415 Overview

Barrier Strip Terminal Block, 20A, 1 Row(s), 1 Deck(s)

RSB6SM27200415 Parametric

Parameter NameAttribute value
MakerThomas & Betts Corporation
Reach Compliance Codeunknow
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberRSB6
Installation typeBOARD
Number of layers1
Rows1
Number of channels27
Rated current20 A
Rated voltage300 V
safety certificateUL
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge14 AWG
Barrier Strips
Tri-Barriers
0.375" PITCH
SERIES RSB6
P
HYSICAL
P
ROPERTIES
H
OUSING
M
ATERIAL
:
Polypropylene
F
LAMMABILITY
:
UL94V-2
C
OLOR
:
Black
T
ERMINAL
T
ERMINALS
:
Brass, bright acid tin over copper plating
S
CREW
:
Steel w/Zinc + Chromate plating
C
LAMP
:
Steel w/Zinc + Chromate plating
RSB6RP##1102
Dimensions
M
ECHANICAL
P
ITCH
(T
ERMINAL
S
PACING
):
.375"
S
CREW
S
IZE
:
6-32
R
ECOMMENDED
PCB H
OLE
D
IA
.:
.062"
W
IRE
S
TRIP
L
ENGTH
:
.38"
R
ECOMMENDED
T
IGHTENING
T
ORQUE
:
9 in lbs.
R
ECOMMENDED
S
CREWDRIVERS
:
Stanley 1006-4,
Sears Craftsman 41581, Any #2 Phillips-Head
W
IRE
L
UG
W
IDTH
(M
AX
.):
8,1mm (.320")
CIRCUITS
(NOT
POSITIONS)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
C1
IN.
L1*
IN.
C2
IN.
.75
L2*
IN.
1.22
1.59
1.97
2.34
2.72
3.09
3.47
3.84
3.84
4.59
4.97
5.34
5.72
6.09
6.47
6.84
7.22
7.59
7.97
8.34
8.72
9.09
9.47
9.84
10.22
10.59
10.97
11.34
11.72
12.09
12.47
12.84
13.22
13.59
13.97
14.34
.37
.75
1.13
1.50
1.88
2.25
2.63
3.00
3.37
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
12.00
12.38
12.75
13.13
.84
1.22
1.59
1.97
2.34
2.72
3.09
3.47
3.84
4.22
4.59
4.97
5.34
5.72
6.09
6.47
6.84
7.22
7.59
7.97
8.34
8.72
9.09
9.47
9.84
10.22
10.59
10.97
11.34
11.72
12.09
12.47
12.84
13.22
13.59
1.13
1.50
1.88
2.25
2.63
3.00
3.37
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.75
9.75
10.13
10.50
10.88
11.25
11.63
12.00
12.38
12.75
13.13
13.50
13.88
E
LECTRICAL
P
ROPERTIES
M
AXIMUM
C
URRENT
:
20A
O
PERATING
V
OLTAGE
:
300V
W
IRE
R
ANGE
:
(Clamp Screw) #12 max AWG
(Binding Head Screw) #14 max AWG
D
IELECTRIC
W
ITHSTAND
:
3500V
E
NVIRONMENTAL
P
ROPERTIES
O
PERATING
T
EMPERATURE
R
ANGE
:-60ºC
to +105ºC
(-76ºF to +221ºF)
Recommended PCB Hole Pattern
34
35
36
C
OMPUTING
RSB B
LOCK
L
ENGTHS
.
D
IRECT
M
OUNTING
Use C1 & L1 for VP, SP, RP, HP mounting
options
E
ND
P
OSITION
M
OUNTING
Use L2 & C2 for VM, SM, RM, VE,
SE, RE mounting options
LR49571
E60980
Thomas & Betts Electronics/OEM Division Tel: 901-252-5000 Fax: 901-252-1312
Dimensions shown are for reference only. Dimensions are in inches.
72
College entrance examination fraud, the monitoring principle of radio signals
A radio fraud incident occurred in Leiyang, Hunan. [url]http://news.163.com/08/0613/06/4EA12JSB0001124J.html[/url] How is the radio signal transmitter located? How to prevent the radio transmission fr...
莫沾衣 MCU
Design of a planar waveguide single pulse comparator
The design of a planar waveguide single pulse comparator is introduced. "Using the waveguide hybrid bridge as the basic structural unit, an X-band single pulse comparator is designed." By adding a qua...
JasonYoo Analog electronics
Ask an interruption question
I got yc2440 and tried to process EINT1 key interrupt. Someone on the yc forum said that CE BSP is special and cannot directly apply for logic interrupt dynamically. So I referred to the logic interru...
huangruihua Embedded System
Application of Industrial Ethernet Switches in Industrial Automation Control Systems
Industrial automation system refers to the general term for automated technical tools (including automatic measuring instruments and control devices) for measuring and controlling industrial productio...
hcl@maiwe.com Industrial Control Electronics
Newbie help
Can you give me one or two simple example programs for LPC21xx, including basic initialization, serial port settings, interrupt usage, etc. I have tried the datasheet and I can't even see the serial p...
wfx198410 Embedded System
When using recvfrom to receive data from socket, only the first character can be received?
I use recvfrom to receive data, and then use messagebox to display it. Every time, only the first character is displayed, and the characters after it become "□". The code is as follows: while(1) { num...
ivanband Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1266  1954  623  2017  83  26  40  13  41  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号