EEWORLDEEWORLDEEWORLD

Part Number

Search

3RHP2850D24

Description
Hybrid Solid State Contactors
File Size377KB,2 Pages
ManufacturerCrydom
Websitehttp://www.crydom.com/en/index.shtml
Download Datasheet View All

3RHP2850D24 Overview

Hybrid Solid State Contactors

3 Phase RHP - Hybrid Solid State Contactors
3 Phase Contactor
AC Input
40-50 Amp
280/600 VAC
ENT
PATDING
PEN
3 Phase Contactor
DC Input
40-50 Amp
120/240 VAC
ENT
PATDING
PEN
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
CONTROL SPECIFICATIONS
Control Voltage Suffix
Coil Voltage Range
Min. Turn-On Voltage
Min. Turn-Off Voltage
Coil Power Consumption, Inrush
Coil Power Consumption, Sealed
Coil Terminals
1
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
DC logic compatible input
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
CONTROL SPECIFICATIONS
Control Voltage Suffix
Control Voltage Range
Max. Reverse Voltage
Min. Turn-On Voltage
Min. Turn-Off Voltage
Input Current
Input Connector
1
E
20 - 26 VAC, 50/60 Hz
20 VAC
12 VAC
56 VA @ 24 VAC
6.6 VA @ 24 VAC
10 in lb (1.13 Nm)
1
F
G
100 - 130 VAC, 50/60 Hz 208 - 240 VAC, 50/60 Hz
100 VAC
208 VAC
24 VAC
48 VAC
56 VA @ 120 VAC
56 VA @ 220 VAC
6.6 VA @ 120 VAC
6.6 VA @ 220 VAC
10 in lb (1.13 Nm)
10 in lb (1.13 Nm)
D5
4.5 - 5.5 VDC
-5.5 VDC
4.5 VDC
1 VDC
12mA @ 5 VDC
5.31 in lb (0.6 Nm)
1
D12
10 - 15 VDC
-15.5 VDC
9.5 VDC
2 VDC
12mA @ 12 VDC
5.31 in lb (0.6 Nm)
D24
22 - 27 VDC
-27.5 VDC
9.5 VDC
2 VDC
12mA @ 24 VDC
5.31 in lb (0.6 Nm)
OUTPUT SPECIFICATIONS
OUTPUT SPECIFICATIONS
28
3
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Screw torque requirements
2
60
48 - 600 VAC
0.06 mA @ 480 VAC
24 - 280 VAC
0.05 mA @ 240 VAC
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Screw torque requirements
12
3
24
208 - 240 VAC
0.06 mA @ 240 VAC
100 - 120 VAC
0.05 mA @ 120 VAC
40
40 A Resistive
Dual quick connect and Binder
head screws / AWG#14 - AWG#8
18 in lbs (2.1 Nm)
50
50 A Resistive
Dual quick connect and Box
lugs / AWG#14 - AWG#6
25 in lbs (2.9 Nm)
40
2
50
40 A Resistive
50 A Resistive
Dual quick connect and Binder Dual quick connect and Box
head screws / AWG#14 - AWG#8 lugs / AWG#14 - AWG#6
18 in lbs (2.1 Nm)
25 in lbs (2.9 Nm)
GENERAL SPECIFICATIONS
1
GENERAL SPECIFICATIONS
4000 VAC
2500 VAC
Three Normally Open
4
1
Input to Output Dielectric Isolation.
Input/Output to Ground Dielectric Isolation.
Contacts (Double Break )
3
Input to Output Dielectric Isolation
Input/Output to Ground Dielectric Isolation
Contacts (Double Break)
3
Ambient Operating Temperature Range
4
4000 VAC
2500 VAC
Three Normally Open
-20°C to 75°C
-40°C to 100°C
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
30 operations per min
> 2 Million operations
540 grs (1.19 lb)
Ambient Operating Temperature Range
Ambient Storage Temperature Range
-20°C to 75°C
-40°C to 100°C
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
30 operations per min
> 2 Million operations
540 grs (1.19 lb)
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
1
2
3
4
Ambient Storage Temperature Range
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
1
2
3
4
Specificationts @ 25°C unless otherwise noted.
See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
Specificationts @ 25°C unless otherwise noted.
See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
Part Number Nomenclature
SERIES
Load Current
40:
40 Amps
50:
50 Amps
Derating Curves
3RHPXX
40
XX
55
3RHPXX
50
XX
Load Current, Amps rms
50
45
40
35
30
3 RHP
Three
Phase
Device
12
40 D5
Nominal Coil
/Control Voltage
D5:
5 VDC
D12:
12 VDC
D24:
24 VDC
E:
24 VAC
F:
120 VAC
G:
220 VAC
Load Current, Amps rms
45
40
Operating
Voltage VAC
50/60 Hz
12:
120 V 1-phase
24:
240 V 3-phase
or 1-phase
28:
280 V 3-phase
60:
600 V 3-phase
35
Power lead size
AWG # 6
AWG # 8
Power lead size
AWG # 6
AWG # 8
30
Safe Operating Area
25
Safe Operating Area
25
20
25
35
45
55
65
75
25
35
45
55
65
75
20
Ambient Temperature, °C
Ambient Temperature, °C

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2748  1687  928  2830  2269  56  34  19  57  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号