EEWORLDEEWORLDEEWORLD

Part Number

Search

3RHP6050D5

Description
Hybrid Solid State Contactors
File Size377KB,2 Pages
ManufacturerCrydom
Websitehttp://www.crydom.com/en/index.shtml
Download Datasheet View All

3RHP6050D5 Overview

Hybrid Solid State Contactors

3 Phase RHP - Hybrid Solid State Contactors
3 Phase Contactor
AC Input
40-50 Amp
280/600 VAC
ENT
PATDING
PEN
3 Phase Contactor
DC Input
40-50 Amp
120/240 VAC
ENT
PATDING
PEN
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
CONTROL SPECIFICATIONS
Control Voltage Suffix
Coil Voltage Range
Min. Turn-On Voltage
Min. Turn-Off Voltage
Coil Power Consumption, Inrush
Coil Power Consumption, Sealed
Coil Terminals
1
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
DC logic compatible input
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
CONTROL SPECIFICATIONS
Control Voltage Suffix
Control Voltage Range
Max. Reverse Voltage
Min. Turn-On Voltage
Min. Turn-Off Voltage
Input Current
Input Connector
1
E
20 - 26 VAC, 50/60 Hz
20 VAC
12 VAC
56 VA @ 24 VAC
6.6 VA @ 24 VAC
10 in lb (1.13 Nm)
1
F
G
100 - 130 VAC, 50/60 Hz 208 - 240 VAC, 50/60 Hz
100 VAC
208 VAC
24 VAC
48 VAC
56 VA @ 120 VAC
56 VA @ 220 VAC
6.6 VA @ 120 VAC
6.6 VA @ 220 VAC
10 in lb (1.13 Nm)
10 in lb (1.13 Nm)
D5
4.5 - 5.5 VDC
-5.5 VDC
4.5 VDC
1 VDC
12mA @ 5 VDC
5.31 in lb (0.6 Nm)
1
D12
10 - 15 VDC
-15.5 VDC
9.5 VDC
2 VDC
12mA @ 12 VDC
5.31 in lb (0.6 Nm)
D24
22 - 27 VDC
-27.5 VDC
9.5 VDC
2 VDC
12mA @ 24 VDC
5.31 in lb (0.6 Nm)
OUTPUT SPECIFICATIONS
OUTPUT SPECIFICATIONS
28
3
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Screw torque requirements
2
60
48 - 600 VAC
0.06 mA @ 480 VAC
24 - 280 VAC
0.05 mA @ 240 VAC
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Screw torque requirements
12
3
24
208 - 240 VAC
0.06 mA @ 240 VAC
100 - 120 VAC
0.05 mA @ 120 VAC
40
40 A Resistive
Dual quick connect and Binder
head screws / AWG#14 - AWG#8
18 in lbs (2.1 Nm)
50
50 A Resistive
Dual quick connect and Box
lugs / AWG#14 - AWG#6
25 in lbs (2.9 Nm)
40
2
50
40 A Resistive
50 A Resistive
Dual quick connect and Binder Dual quick connect and Box
head screws / AWG#14 - AWG#8 lugs / AWG#14 - AWG#6
18 in lbs (2.1 Nm)
25 in lbs (2.9 Nm)
GENERAL SPECIFICATIONS
1
GENERAL SPECIFICATIONS
4000 VAC
2500 VAC
Three Normally Open
4
1
Input to Output Dielectric Isolation.
Input/Output to Ground Dielectric Isolation.
Contacts (Double Break )
3
Input to Output Dielectric Isolation
Input/Output to Ground Dielectric Isolation
Contacts (Double Break)
3
Ambient Operating Temperature Range
4
4000 VAC
2500 VAC
Three Normally Open
-20°C to 75°C
-40°C to 100°C
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
30 operations per min
> 2 Million operations
540 grs (1.19 lb)
Ambient Operating Temperature Range
Ambient Storage Temperature Range
-20°C to 75°C
-40°C to 100°C
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
30 operations per min
> 2 Million operations
540 grs (1.19 lb)
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
1
2
3
4
Ambient Storage Temperature Range
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
1
2
3
4
Specificationts @ 25°C unless otherwise noted.
See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
Specificationts @ 25°C unless otherwise noted.
See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
Part Number Nomenclature
SERIES
Load Current
40:
40 Amps
50:
50 Amps
Derating Curves
3RHPXX
40
XX
55
3RHPXX
50
XX
Load Current, Amps rms
50
45
40
35
30
3 RHP
Three
Phase
Device
12
40 D5
Nominal Coil
/Control Voltage
D5:
5 VDC
D12:
12 VDC
D24:
24 VDC
E:
24 VAC
F:
120 VAC
G:
220 VAC
Load Current, Amps rms
45
40
Operating
Voltage VAC
50/60 Hz
12:
120 V 1-phase
24:
240 V 3-phase
or 1-phase
28:
280 V 3-phase
60:
600 V 3-phase
35
Power lead size
AWG # 6
AWG # 8
Power lead size
AWG # 6
AWG # 8
30
Safe Operating Area
25
Safe Operating Area
25
20
25
35
45
55
65
75
25
35
45
55
65
75
20
Ambient Temperature, °C
Ambient Temperature, °C
Telecommunications Technology Glossary: EDGE Technology Explained
EDGE is the abbreviation of Enhanced Data Rate for GSM Evolution. EDGE is a transitional technology from GSM to 3G. It mainly adopts a new modulation method in the GSM system, namely the most advanced...
songbo RF/Wirelessly
How to draw with bitmap data in memory?
The data in the memory is a decompressed bmp file, which is a complete bmp file, including BITMAPFILEHEADER, BITMAPINFO and other data. Now I want to use the data in the bitmap to draw a picture. How ...
manbuzhe Embedded System
I will comment on solar photovoltaic power generation solutions
Solar photovoltaic power generation is green, environmentally friendly and low-carbon. Main challenges and system considerations Higher reliability and lower assembly/manufacturing costs Relatively ha...
gs001588 ADI Reference Circuit
If I find an error in a post I posted, can I edit it?
I found an error in my post after posting, and I want to edit it, but I can't find the edit tag. I would like to ask the forum administrator: If I find an error in my post, can I still edit it? Thank ...
yhye2world Suggestions & Announcements
JTAG 2 pin voltage problem
No matter how I measure the voltage on my JTAG2 pin, there is no voltage. So I can't connect to my target board hardware because there is no power. My board's VCC is connected to the JTAG2 pin. I want...
wdyzleilei Microcontroller MCU
About low power consumption hardware and software design
1. For functional modules with high current consumption, whether internal or external, shut down (including software disabling). Internal modules include SVS, ADC, REF, and external modules such as se...
eleclike MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 388  1930  341  1969  811  8  39  7  40  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号