EEWORLDEEWORLDEEWORLD

Part Number

Search

3RT1025-3XB40-0LA2

Description
Contactors with Extended Tolerance 0.7 ... 1.25 x , for Railway Applications
Categoryunclassified   
File Size1MB,76 Pages
ManufacturerSIEMENS
Websitehttp://www.infineon.com/
Download Datasheet View All

3RT1025-3XB40-0LA2 Overview

Contactors with Extended Tolerance 0.7 ... 1.25 x , for Railway Applications

3RT, 3RH, 3TB, 3TC, 3TH, 3TK Contactors for Special Applications
Contactors with Extended Tolerance 0.7 ... 1.25 x U
s
, for Railway Applications
3RT10 motor contactors, 5.5 ... 45 kW
DC operation · DC solenoid system
Screw terminals
For screw and snap-on mounting onto standard mounting rail
Contactor control unit
Solenoid fitted with varistor
Rated data
AC-2 and AC-3
T
u
: up to 70 °C
Rated
operational
current
I
e
at
400 V
A
Auxiliary contacts
1)
Rated control DT
supply voltage
U
s
Screw terminals
PU
PS*
(UNIT,
SET, M)
Price
per PU
PG
Weight
per PU
approx.
Rating of
induction
Ident.
motors at 50 Hz No.
400 V
kW
Order No.
Version
NO
NC
V DC
kg
For screw and snap-on mounting onto
35 mm standard mounting rail
Size S0
17
25
7.5
11
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
24
110
24
110
24
110
24
110
24
110
B
B
B
B
B
B
B
B
B
B
3RT10 25-1XB40-0LA2
3RT10 25-1XF40-0LA2
3RT10 26-1XB40-0LA2
3RT10 26-1XF40-0LA2
3RT10 34-1XB40-0LA2
3RT10 34-1XF40-0LA2
3RT10 35-1XB40-0LA2
3RT10 35-1XF40-0LA2
3RT10 36-1XB40-0LA2
3RT10 36-1XF40-0LA2
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
101
101
101
101
101
101
101
101
101
101
0.625
0.340
0.627
0.445
1.432
1.505
1.491
1.432
1.491
1.432
Size S2
32
40
50
15
18.5
22
For screw and snap-on mounting onto
35 mm and 75 mm standard mounting rail
Size S3
65
80
95
30
37
45
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
24
110
24
110
24
110
B
B
B
B
B
B
3RT10 44-1XB40-0LA2
3RT10 44-1XF40-0LA2
3RT10 45-1XB40-0LA2
3RT10 45-1XF40-0LA2
3RT10 46-1XB40-0LA2
3RT10 46-1XF40-0LA2
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
101
101
101
101
101
101
2.864
2.775
2.871
2.720
2.913
2.913
1) Auxiliary switch blocks mountable as standard contactors.
* You can order this quantity or a multiple thereof.
Siemens LV 1 · 2006
3/71
3
Ask a question about converting decimal into binary on a microcontroller
I use a matrix keyboard to input a two-digit decimal number. How can I convert it into binary and input it into the FPGA? For example, 23 becomes 0001 0111. Note that it is not converted into BCD code...
影子刺客 Microcontroller MCU
"Wanli" Raspberry Pi car open source sharing summary——lb8820265
Yesterday, @lb8820265, who had not appeared in the forum for a long time, was all over the screen~ He brought his "Wanli" car back to the forum. He is looking forward to friends who like it to play wi...
EEWORLD社区 DIY/Open Source Hardware
Can resend data
When I use CAN communication and PC communication, the DSP count only sends 10000 data, but the CAN card receives 10010 data. Later, I found that there are duplicate data and the DSP resents. What's g...
zqshan DSP and ARM Processors
Help: A 8086 program, looking for expert guidance
A 8086 program performs multiplication of two 32-bit numbers. I am confused because I have just started learning it. The program is as follows: data segment mulnum dw 0000,0fffh,0000,offfh,4dup(?) dat...
zzzhhhxxx MCU
How to filter square waves into round ones?
As shown in Figure 1, I know how to calculate RC filtering. I know the frequency of the square wave and the three RC constants reach full amplitude. The filtering effect is a bit like a dorsal fin sha...
REMY Analog electronics
Looking for UCOSII+LWIP routines for 8962 board
Now the company needs to use the function of 8962. I heard that Zhou Ligong has UCOSII+LWIP routines. Can anyone send me a copy? My email address is [email]cqmky@163.com[/email] QQ: 93432106 Thank you...
fengzhang2002 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 768  266  2682  2046  1926  16  6  54  42  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号