EEWORLDEEWORLDEEWORLD

Part Number

Search

L12-B0-42-410-45B-CG

Description
Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size2MB,8 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

L12-B0-42-410-45B-CG Overview

Magnetic Circuit Breaker,

L12-B0-42-410-45B-CG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompli
Circuit protection typeMAGNETIC CIRCUIT BREAKER
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
AD5933 has large impedance measurement error
My goal is to measure the impedance value of the coil. First, I used 100 ohms as the correction resistor, and the feedback resistor was connected to a 100Ω resistor. The excitation amplitude is 2Vp-p ...
abwdh ADI Reference Circuit
Who knows the information about this experimental board? Urgent!
I have a PD-51 board on hand, which is Zhou Ligong's board, but I don't have any information on hand, so if you have it, please give me a copy... Thank you! http://www.embedtools.com/pro_kaifa/51/51+....
小小白 51mcu
SDRAM data line interface circuit
When I was looking at the schematic diagram of the EVM board of DM642, I found that when the data lines of SDRAM are connected to the data lines of EMIF, every other byte is connected in reverse order...
slevin Analogue and Mixed Signal
Please recommend a microcontroller with 5 16-bit timers!
Please recommend a microcontroller with 5 16-bit timers!I wish you all happiness every day!...
lei619lei MCU
Could you please tell me how the kernel version management is currently implemented?
There are more and more versions now, and I hope to communicate with you on how to better manage versions....
cnnbxc Embedded System
Why does op produce a 90° phase delay when it is connected to a capacitive load? ? ? ?
[align=center][/align] [align=left]Shouldn't op alone produce a phase shift of -180 degrees? How come it is 90 degrees? [/align] [align=left]I would like to ask the experts for help[/align]...
涛声依旧00 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 655  1314  764  731  1488  14  27  16  15  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号