EEWORLDEEWORLDEEWORLD

Part Number

Search

440L-P4K0640YD

Description
Safety Light Curtains
File Size165KB,7 Pages
ManufacturerALLEN BRADLEY
Download Datasheet View All

440L-P4K0640YD Overview

Safety Light Curtains

Presence Sensing Safety Devices
Safety Light Curtains
GuardShield Type 4
Specifications
Standards
Approvals
Protected Height
Scanning Range/Resolution
Resolution
Enclosure Rating
Connection Type
EN 61496 Parts 1 & 2
TUV and CE marked for all applicable
directives; UL 61496, UL 1998
160mm...1760mm (6.3in...69.3in) in
160mm (6.3in) increments
0.3-7m/14mm (0.98-22.9ft/0.55in)
0.3m-18m/30mm (0.98-59ft/1.18in)
14mm/30mm (0.55in/1.18in)
IP 65
Transmitter: 4-pin micro QD
Receiver: 8-pin micro QD
24V DC
±
20%
5 Vss
0.9...2 Amps (no-load) 0.4A max (no
load)
Optical, without separate
synchronization channel
2 x PNP, 0.5 A, short circuit protected
1 x PNP 0.5A max.
Uv - 2V
Depending on number of beams
Short circuit and overload
30m (100ft) max.
Manual or automatic restart
Type 4 (self-checking) per EN 61496
-10°C to 55°C (14°F to 131°F)
15%...95% (not condensing)
-25°C to 75°C (-13°F to 167°F)
Length dependent upon protected
height; (see dimensional drawings)
40 mm x 50 mm (1.57in x 1.96in)
870nm
IEC60068-2-6, frequency 10Hz to 55Hz
Amplitude: 0.35mm (0.01in)
IEC60068-2-29 acceleration 10g, pulse
duration 16ms
Description
The Allen-Bradley Guardmaster GuardShield safety light curtain is
an economical, fully featured, Type 4 safety light curtain in a
uniquely styled housing. GuardShield safety light curtains are general
purpose presence sensing devices designed for use on hazardous
machinery providing point of operation, as well as perimeter and
access guarding. This self-contained, two box, safety light curtain has
DIP switch selectable operating modes and are available in both
14mm and 30mm resolutions.
Modes of operation such as fixed and floating blanking, beam
coding, start/restart interlock, external device monitoring (EDM),
machine test signal, are selected by dip-switches settings. These dip-
switches are located beneath a security door, which are conveniently
located on both the transmitter and receiver end caps.
The GuardShield’s torsionally rigid, extruded aluminium,
polyurethane powder coated housing, combined with an
Environmental rating of IP65, allows the GuardShield to be used in
guarding applications across a broad range of industries.
Supply Voltage Uv
Maximum Residual Ripple
Power Consumption
Synchronization
Outputs—Safety
Output—Non safety
Minimum Output Voltage
Response Time
Protection
Cable Length
Mode of Operation
Safety Category
Operating Ambient Temp.
Air Humidity
Storage Temperature
Approximate Dimensions
Height
Housing Cross Section
Transmitter Wavelength
Vibration Resistance
Shock
Features
Fixed blanking—teachable
Floating blanking—one or two beam
Beam coding
External Device Monitoring (EDM)
Start/restart interlock
Note:
The external power supply must be capable of buffering brief
power failures of 20ms as specified in IEC 60204.
2-8
Implementing a Simple Keyboard Controller Using CPLD
[i=s] This post was last edited by paulhyde on 2014-9-15 08:55 [/i] Using CPLD to implement a simple keyboard controller...
xiangzi001 Electronics Design Contest
Samsung 753DF and 755DF monitor pictures
[i=s] This post was last edited by jameswangsynnex on 2015-3-3 19:56 [/i] Samsung 753DFhe755DF monitor pictures...
feifei Mobile and portable
Is there anyone who has used USB3320 as a USB interface? Please come in and help! ! !
Why does the chip keep sending data after I initialize it? The document says that after power-on reset, it will only send a state change rxcmd, and then release the data direction control bit and data...
dabaobao FPGA/CPLD
Automatic pet feeding device | Creative progress post
[size=5]Weekly plan: [url=https://bbs.eeworld.com.cn/thread-380398-1-1.html]https://bbs.eeworld.com.cn/thread-380398-1-1.html[/url] The following will report according to the weekly opportunity reply....
zca123 Renesas Electronics MCUs
Earn points, settle quickly
...
barium2000 Embedded System
Introduction to the method of board-level online compilation and downloading of C6000 DSP code
Traditional C6000 DSP software is compiled and debugged on a WINDOWS PC through CCS. After testing, the compiled executable file is burned into FLASH. By setting the DSP startup mode to start from FLA...
fish001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 790  2442  1455  1418  1356  16  50  30  29  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号