EEWORLDEEWORLDEEWORLD

Part Number

Search

62-02227-20-03001

Description
Fiber Optic ST Connector
CategoryThe connector    The connector   
File Size566KB,1 Pages
ManufacturerGould Fiber Optics
Download Datasheet Parametric View All

62-02227-20-03001 Overview

Fiber Optic ST Connector

62-02227-20-03001 Parametric

Parameter NameAttribute value
MakerGould Fiber Optics
Reach Compliance Codeunknow
Connector typeFIBER OPTIC ST CONNECTOR
Manufacturer's serial number6
PATCH CORDS
Gould optical cable assemblies feature quality parts and guaranteed performance specifications.
•Length tolerance is ±10% (minimum tolerance is ±5cm)
•Specifications are per mated pair at both 1310nm and 1550nm
Connector Insertion/Return Loss
Specifications for SMF-28 Fiber
End
Number
2
3
4
5
6
7
Connector
Insertion
Loss (dB)
≤ 0.5
≤ 0.25
≤ 0.25
< 0.25
≤ 0.25
≤ 0.25
Typical
Return
Loss (dB)
> 40
> 50
> 50
> 40
> 60
> 60
Features
Low Optical Loss
Low Polarization
Dependent Loss
Applications
Telecom
Instrumentation
Medical
ST
FC
SC
LC
FC/APC
SC/APC
PATCH CORDS
Product #:
6
-
-
Connector
End A
2
3
4
5
6
7
ST/UPC
FC/UPC
SC/UPC
LC/UPC
FC/APC
SC/APC
0
2
3
4
5
6
7
-
Connector
End B
Pigtail
assembly
ST/UPC
FC/UPC
SC/UPC
LC/UPC
FC/APC
SC/APC
Buffer Type
Length in
meters xxxx
0300
0350
3m
3.5m
etc
1
Patchcord Type
2
4
singlemode
multimode
Testing Requirements
0
1
2
3
insertion loss testing data only
insertion loss and return loss testing data
insertion loss and endface geometry data
insertion loss, return loss and endface
geometry data
Fiber Type
03
06
11
12
22
23
25
27
32
54
Corning SMF-28
TM
, 100kpsi proof test on fiber
Corning Flexcore (5/125)
50/125 Graded Index (Corning)
62.5/125 Graded Index (Corning)
200/230/500, 0.37NA SI MM HCS (Lucent)
200/230/500, 0.48NA SI MM HCS (Lucent)
100/140/250 Step Index (Lucent)
Corning Flecore (7/125)
Corning SMF-28
TM
, 200 kspi proof test on fiber
Corning Flecore (7/125), 200 kspi proof test on fiber
10
21
22
23
24
25
26
27
28
29
31
32
33
34
No buffering ( not recommended)
900 micron, white, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, orange, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, blue, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, red, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, green, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, black, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, brown, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, gray/slate, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
900 micron, yellow, hytrel (temp rating -20 to +70
o
C, UL 94V-HM rated)
2.9mm x 0.4mm, Kevlar reinforced tubing, yellow
2.9mm x 0.4mm, Kevlar reinforced tubing, orange
2.9mm x 0.9mm, Kevlar reinforced tubing, orange
2.9mm x 0.45mm, Kevlar reinforced tubing, black
Specifications are based on non-connectorized products. For connectorized specifications, please call
sales for details. Custom optical & mechanical configurations are available upon request.
46
Call Toll Free: 1-800-544-6853 • FAX: 410-987-1201 • E-mail: info@gouldfo.com
*Hello experts: I want to make a software that runs on SP and PPC mobile phones, how can I do it?
The program is very simple, it only needs to use webservice and browse the web. I want to use EVC4 to develop, but it can only make mobile 5.0 programs. Can I ask you, if a mobile 5.0 program needs to...
fox5520 Embedded System
The bravest wins when two meet on a narrow road
Animation on the Internet...
daijun Talking
My emergency lights were on for more than half a day, 13 hours
I have time on Sunday. I start to recharge in the morning, and then I go to do other things. In the afternoon, at 17:30, the emergency lights started to work. When I went to work at around 6:36 in the...
ddllxxrr DIY/Open Source Hardware
Zhang Qiang Components Retail Supply and Demand Repost
[i=s]This post was last edited by paulhyde on 2014-9-15 09:19[/i] [b]Shenzhen Maiweida Electronics Co., Ltd.[/b] Zhang Qiang R&D Project Manager[b]Tel:[/b]15813708242 0755-86656088-507 [b]Email:[/b][e...
EEW Electronics Design Contest
stm32 fsmc nand hardware ecc error problem
When I was initializing STM32 --- NAND (K9F1208U0B), an error kept occurring when generating hardware ecc. It was very puzzling. I would like to ask for some advice from experts... Thank you! The code...
a921844729 stm32/stm8
How to control line width and current in PCB wiring?
When we draw PCB, we generally have a common sense, that is, use thick wires (such as 50mil or even more) for places with large current, and use thin wires (such as 10mil) for small current signals. F...
qwqwqw2088 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1529  2852  2810  1558  2196  31  58  57  32  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号