EEWORLDEEWORLDEEWORLD

Part Number

Search

59052-X-S-02-D

Description
Firecracker Features and Benefits
File Size77KB,1 Pages
ManufacturerHamlin ( Littelfuse )
Websitehttp://www.hamlin.com
Download Datasheet View All

59052-X-S-02-D Overview

Firecracker Features and Benefits

www.hamlin.com
File E61760(N)
Actuator
59025 Firecracker Features and Benefits
Features
2 part magnetically operated
proximity sensor
UL recognised
Choice of normally open, normally
closed or change over contacts
Customer defined sensitivity
Choice of cable length and
connector
Benefits
Quick and easy to install
No standby power requirement
Operates through non-ferrous
materials such as wood, plastic or
aluminium
Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
Applications
Position and limit sensing
Security
Level sensing
Linear actuators
Sensor
DIMENSIONS (in) mm
A
Max
57025
59025
(.245) 6,22
(.245) 6,22
B
Max
(1.000) 25,40
(1.000) 25,40
C
NOM.
-
Table 3 ± (.393) 10,00
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
Contact Type
Switch Type
Power
Voltage
Current
Resistance
Capacitance
Temperature
Time
Shock
Vibration
Switching
Breakdown
Switching
Carry
Contact, Initial
Insulation
Contact
Operating
Storage
Operate
Release
11ms 1⁄2 sine
50-2000 Hz
Watt - max.
Vdc - max.
Vdc - min.
A - max.
A - max.
- max.
- min.
pF - typ.
°C
°C
ms - max.
ms - max.
G - max.
G - max.
Form A
Normally
Open
1
10
200
250
0.5
1.2
0.2
10
10
0.3
-40 to +105
-65 to +105
1.0
1.0
100
30
Normally Open
High Voltage
2
10
300
450
0.5
1.5
0.2
10
10
0.2
-20 to +105
-65 to +105
1.0
1.0
100
30
Change
Over
3
5
175
200
0.25
1.5
0.2
10
9
0.3
-40 to +105
-65 to +105
3.0
3.0
50
30
Normally
Closed
4
5
175
200
0.25
1.5
0.2
10
9
0.3
-40 to +105
-65 to +105
3.0
3.0
50
30
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
TABLE 2
Sensitivity Options:-
Activate Distances are approximate
using Hamlin 57025 actuator
as illustrated
Switch AT before modification
TABLE 3
Cable Type:-
24 AWG 7/32 PVC 105
o
C
UL1430/UL1569
TABLE 4
Termination Options:-
SELECT
OPTION
DESCRIPTION
(2
WIRE VERSIONS ILLUSTRATED
)
Standard Lengths
SELECT
OPTION
CABLE
LENGTH
A or F
B
C
D
E
Tinned or untinned leads
Crimped terminals
6.35mm fastons
AMP MTE 2.54mm pitch
JST XHP 2.5mm pitch
Select Option
Switch
Type
1
2
3
4
S
Pull In
AT
Range
Activate
Distance
d
(in) mm
(.315)
8.0
(.276)
7.0
Pull In
AT
Range
17-23
20-25
T
Activate
Distance
d
(in) mm
(.236)
6.0
(.216)
5.5
Pull In
AT
Range
22-28
25-30
U
Activate
Distance
d
(in) mm
(.197)
5.0
(.177)
4.5
Pull In
AT
Range
27-33
V
Activate
Distance
d
(in) mm
(.157)
4.0
01
02
03
04
05
(in)
mm
(3,94) 100
(11,81) 300
(19,69) 500
(29,53) 750
(39,37) 1000
Normally Open 12-18
High Voltage
Change Over
15-20
Normally Closed
ORDERING INFORMATION
N.B. 57025 actuator sold separately
59025
59036
Table 1
Table 2
Table 3
2
Table 4
3
X
X
T
XX
X
Series 59025
Switch Type
Sensitivity
Cable Length
Termination
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
ISSUE No: 4 DATE: 1/5/3
Tel:
Tel:
Tel:
Tel:
+1 920 648 3000
Fax: +1 920 648 3001
Email: sales.us@hamlin.com
+44 (0)1379 649700
Fax: +44 (0)1379 649702
Email: sales.uk@hamlin.com
+49 (0) 6181 953660
Fax: +49 (0) 6181 9536666
Email: sales.de@hamlin.com
+33 (0) 1 4687 0202
Fax: +33 (0) 1 4686 6786
Email: sales.fr@hamlin.com
22
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
Problems with synchronization with PC after adding WinCE screen saver password?
The customer requires our WinCE device to use a screen saver. According to the help of WinCE, after adding two registry entries, the screen saver can run normally. However, after setting the screen sa...
lranseti Embedded System
AD sampling trigger source
When the sampling trigger source of AD is selected as timer trigger, why don't I configure the timer? How to achieve triggering...
ljk926 Microcontroller MCU
I have a 90% new Spartan 3e development board for sale.
I have an idle spantan3e 500 development board. The price is 1050. If you need it, you can contact me via QQ: 247287388 The price can be small...
pengwr Buy&Sell
Heartbreak
I don’t know what’s wrong with me lately. I’ve become quieter and quieter and less and less willing to talk. Would it really be better if we didn't make any noise? Traces of Sorrow——Overflowing with S...
jbjhl504 Talking
Can DXP2004 draw square holes? Please give me some advice!
I am currently drawing a component package. The pins are rectangular, but the holes in DXP are round. Is there any way to draw a pad with a square hole? Does anyone know how to do this? Could you plea...
280987343 PCB Design
How to convert erilog program file to bsf file?
I am a beginner and have just come into contact with FPGA. I have encountered some problems and hope that experts can give me some advice. How to convert erilog program files into bsf files?...
zhenpeng25 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 938  463  45  2393  2694  19  10  1  49  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号