EEWORLDEEWORLDEEWORLD

Part Number

Search

590752-S-04-A

Description
Heavy Duty Stainless Steel Threaded Barrel Features and Benefits
File Size83KB,1 Pages
ManufacturerHamlin ( Littelfuse )
Websitehttp://www.hamlin.com
Download Datasheet View All

590752-S-04-A Overview

Heavy Duty Stainless Steel Threaded Barrel Features and Benefits

www.hamlin.com
59075 Heavy Duty Stainless Steel Threaded Barrel Features and Benefits
57075 Actuator
Features
2 part magnetically operated
proximity sensor
Heavy duty stainless steel threaded
barrel with retaining nuts
M12 by 1.00mm thread
Choice of normally open, high
voltage or change over contacts
Customer defined sensitivity
Choice of cable length and
connector
Benefits
Robust construction makes this
sensor well suited to harsh
industrial environments
Simple installation and adjustment
using supplied retaining nuts
No standby power requirement
Operates through non-ferrous
materials such as wood, plastic or
aluminium
Applications
Off road and heavy vehicles
Farm machinery
59075 Sensor
DIMENSIONS (in) mm
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
Contact Type
Switch Type
Power
Voltage
Current
Resistance
Capacitance
Temperature
Time
Shock
Vibration
Switching
Breakdown
Switching
Carry
Contact, Initial
Insulation
Contact
Operating
Storage
Operate
Release
11ms 1⁄2 sine
50-2000 Hz
Watt - max.
Vdc - max.
Vdc - min.
A - max.
A - max.
- max.
- min.
pF - typ.
°C
°C
ms - max.
ms - max.
G - max.
G - max.
Form A
Normally
Open
1
10
200
250
0.5
1.2
0.2
10
10
0.3
-40 to +85
-65 to +85
1.0
1.0
100
30
Normally Open
High Voltage
2
10
300
450
0.5
1.5
0.2
10
10
0.2
-20 to +85
-65 to +85
1.0
1.0
100
30
Change
Over
3
5
175
200
0.25
1.5
0.2
10
9
0.3
-40 to +85
-65 to +85
3.0
3.0
50
30
Normally
Closed
4
5
175
200
0.25
1.5
0.2
10
9
0.3
-40 to +85
-65 to +85
3.0
3.0
50
30
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
TABLE 2
Sensitivity Options:-
Activate Distances are approximate
using Hamlin 57075 actuator
as illustrated
Switch AT before modification
TABLE 3
Cable Type:-
BS 6500 3A 16/0.2 PVC
DOUBLE INSULATED
TABLE 4
Termination Options:-
SELECT
OPTION
DESCRIPTION
(2
WIRE VERSIONS ILLUSTRATED
)
Standard Lengths
SELECT
OPTION
CABLE
LENGTH
A or F Tinned or untinned leads
Select Option
Switch
Type
1
2
3
4
S
Pull In
AT
Range
Activate
Distance
d
(in) mm
(.984)
25,0
(.906)
23,0
Pull In
AT
Range
17-23
20-25
T
Activate
Distance
d
(in) mm
(.827)
21,0
(.787)
20,0
Pull In
AT
Range
22-28
25-30
U
Activate
Distance
d
(in) mm
(.748)
19,0
(.709)
18,0
Pull In
AT
Range
27-33
V
Activate
Distance
d
(in) mm
(.689)
17,5
01
02
03
04
05
(in)
mm
(3,94) 100
(11,81) 300
(19,69) 500
(29,53) 750
(39,37) 1000
C
6.35mm fastons
B
Crimped terminals
Normally Open 12-18
High Voltage
Change Over
15-20
Normally Closed
ORDERING INFORMATION
N.B. 57075 actuator sold separately
59075
59036
Table 1
Table 2
Table 3
Table 4
X
X
XX
X
Series 59075
Switch Type
Sensitivity
Cable Length
Termination
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
ISSUE No:
5
DATE:
16/10/08
Tel:
Tel:
Tel:
Tel:
+1 920 648 3000
Fax: +1 920 648 3001
Email: sales.us@hamlin.com
+44 (0)1379 649700
Fax: +44 (0)1379 649702
Email: sales.uk@hamlin.com
+49 (0)
6142 923920
Fax: +49 (0)
6142923921
Email: sales.de@hamlin.com
+33 (0) 1
6047 3000
Fax: +33 (0) 1
6015 9136
Email: sales.fr@hamlin.com
28
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
How do logical 0 and 1 generate different physical signals?
Hello everyone, I've been thinking about a question recently: We can use physical tools such as keyboards to form the on and off of current/high and low voltage; Then, some physical properties of semi...
njnujjq Embedded System
Ask about keyboard events
My wince system has no display device, and the programs are all non-graphical, that is, there is no window, so how can my program respond to a keyboard event? I see that the keyboard event should be s...
jsglf Embedded System
[Automatic clock-in and walking timing system based on face recognition] BLE automatic time calibration and scanning wearable watch/scan
The entry for the Digi-Key 2022 Electronic Innovation Design Competition has been submitted, but considering the integrity of the front and back designs, I am considering opening a separate post to sh...
alanlan86 DigiKey Technology Zone
Low pass filter cutoff frequency algorithm
I would like to ask how to calculate the cutoff frequency of this fourth-order low-pass filter. Can you give me a little more specific information? Thanks!...
SEVEN917 Analog electronics
幾個AVR的資料
不錯的幾個AVR資料,拿出來大家分享...
zcm Microchip MCU
Serial communication in linux
[i=s]This post was last edited by pii on 2017-3-10 14:36[/i] I bought a lock control board from Taobao, and used a USB adapter to connect to the RS232 to RS485 board. I used a serial communication too...
pii Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 695  989  2613  424  1986  14  20  53  9  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号