EEWORLDEEWORLDEEWORLD

Part Number

Search

59090-3-T-01-C

Description
Heavy Duty Vane Sensor Features and Benefits
File Size87KB,1 Pages
ManufacturerHamlin ( Littelfuse )
Websitehttp://www.hamlin.com
Download Datasheet View All

59090-3-T-01-C Online Shopping

Suppliers Part Number Price MOQ In stock  
59090-3-T-01-C - - View Buy Now

59090-3-T-01-C Overview

Heavy Duty Vane Sensor Features and Benefits

www.hamlin.com
59090 Heavy Duty Vane Sensor Features and Benefits
Features
Sensor and magnet contained in
single housing
Sensor operates when ferrous vane
passes through slot
Normally closed standard, normally
closed high voltage or change over
options
Choice of cable length and connector
Benefits
Quick and reliable single screw
mounting with location feature
No standby power requirement
Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
Applications
Position and limit sensing
Security system switch
Linear actuators
Industrial process control
Shaft rotation sensing
DIMENSIONS (in) mm
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
Contact Type
Switch Type
Power
Voltage
Current
Resistance
Capacitance
Temperature
Time
Shock
Vibration
Switching
Breakdown
Switching
Carry
Contact, Initial
Insulation
Contact
Operating
Storage
Operate
Release
11ms 1⁄2 sine
50-2000 Hz
Watt - max.
Vdc - max.
Vdc - min.
A - max.
A - max.
- max.
- min.
pF - typ.
°C
°C
ms - max.
ms - max.
G - max.
G - max.
Form A
Normally
Closed
4
10
200
250
0.5
1.2
0.2
10
10
0.3
-40 to +85
-65 to +85
1.0
1.0
100
30
Normally Closed
High Voltage
5
10
300
450
0.5
1.5
0.2
10
10
0.2
-20 to +85
-65 to +85
1.0
1.0
100
30
Change
Over
3
5
175
200
0.25
1.5
0.2
10
9
0.3
-40 to +85
-65 to +85
3.0
3.0
50
30
CUSTOMER OPTIONS - Cable Length and Termination Specification
TABLE 2
Cable Type:-
BS 6500 3A 16/0.2 PVC
DOUBLE INSULATED
TABLE 3
Termination Options:-
SELECT
OPTION
DESCRIPTION
(2
WIRE VERSIONS ILLUSTRATED
)
ACTIVATION
Standard Lengths
SELECT
OPTION
CABLE
LENGTH
(in)
01
02
03
04
05
mm
A or F
Tinned or untinned leads
(3,94) 100
(11,81) 300
(19,69) 500
(29,53) 750
(39,37) 1000
C
6.35mm fastons
B
Crimped terminals
ORDERING INFORMATION
59090
59036
Series 59090
Switch Type
Sensitivity
Cable Length
Termination
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
ISSUE No:
5
DATE:
16/10/08
X
T
XX
X
Table 1
Table 2
Table 3
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
Tel:
Tel:
Tel:
Tel:
+1 920 648 3000
Fax: +1 920 648 3001
Email: sales.us@hamlin.com
+44 (0)1379 649700
Fax: +44 (0)1379 649702
Email: sales.uk@hamlin.com
+49 (0)
6142 923920
Fax: +49 (0)
6142 923921
Email: sales.de@hamlin.com
+33 (0) 1
6047 3000
Fax: +33 (0) 1
6015 9136
Email: sales.fr@hamlin.com
31
After vmware6.5 is installed, a black screen appears after starting a virtual machine
I have tried the following procedure but it does not work: I have tried the following procedure but it does not work: I have tried the following procedure but it does not work: I have tried the follow...
小美 Embedded System
500k inverter
Is there a 500k inverter circuit you can share?...
xusonxi Power technology
EEWORLD University----TI-RSLK Module 16 - Tachometer
TI-RSLK Module 16 - Tachometer : https://training.eeworld.com.cn/course/4675...
hi5 Talking
STM32 novice project creation
IAR STM32 project creation I have recently learned about STM32 microcontrollers, and I feel that the STM32 library has really improved the efficiency of developers. Some register bit settings are enca...
安_然 stm32/stm8
Pull-up and pull-down resistors
[size=4]A pull-up resistor clamps an uncertain signal at a high level through a resistor, and this resistor also serves as a current limiter. Similarly, a pull-down resistor clamps an uncertain signal...
fish001 Analogue and Mixed Signal
Announcement of the voting results
[color=#ff00][font=微软雅黑][size=5]Winner announcement: [/size][/font][/color] [color=#ff00][font=微软雅黑][size=5]Congratulations to the netizen on the 27th floor: [/size][/font][/color][url=https://bbs.eew...
cardin6 Creative Market

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 471  734  2875  1311  1955  10  15  58  27  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号