EEWORLDEEWORLDEEWORLD

Part Number

Search

687KXM063MRV

Description
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 63 V, 680 uF, THROUGH HOLE MOUNT
CategoryPassive components    capacitor   
File Size411KB,3 Pages
ManufacturerIllinois Capacitor
Websitehttp://www.illinoiscapacitor.com/
Environmental Compliance
Download Datasheet Parametric View All

687KXM063MRV Overview

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 63 V, 680 uF, THROUGH HOLE MOUNT

687KXM063MRV Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerIllinois Capacitor
package instructionRADIAL LEADED, LEAD FREE
Reach Compliance Codecompli
ECCN codeEAR99
capacitance680 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
diameter18 mm
dielectric materialsALUMINUM (WET)
ESR195 mΩ
JESD-609 codee3
leakage current0.4284 mA
length26.5 mm
Manufacturer's serial numberKXM
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-55 °C
Package shapeCYLINDRICAL PACKAGE
Package formRadial
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)63 V
ripple current1404 mA
seriesKXM
surface mountNO
Delta tangent0.08
Terminal surfaceMatte Tin (Sn)
Terminal pitch8 mm
Terminal shapeWIRE
FEATURES
APPLICATIONS
Standardized Case Sizes
-
High Ripple Current
Multiple
Case Sizes
Bypass
Coupling
Filtering
De-coupling
Operating Temperature
Range
Capacitance Tolerance
WVDC
Surge Voltage
SVDC
WVDC
Dissipation
Tan δ
Factor
Leakage Current
Low
Temperature
Stability
Impedance
Ratio
(120 Hz)
-55°C to +105°C
+20% at 120 Hz, 20°C
6.3
7.9
6.3
.22
10
13
10
.19
16
20
16
.16
25
32
25
.14
35
44
35
.12
50
63
50
.1
63
79
63
.1
100
125
100
.1
Add .02 for every 1000uF above 1000uF
2 Minutes
.01CV or 3uA, Whichever is greater
WVDC
-25°C to +20°C
-40°C to +20°C
6.3
4
8
10
3
6
16
2
4
25
2
3
35
2
3
50
2
3
63
2
3
100
2
3
Load Life
Shelf Life
5000 hours at 105°C with rated WVDC and ripple current applied
(4000 hrs for D=10, 3000 Hrs for D=8, 2000 Hrs for D<6.3)
Capacitance Change
<20% of initial measured value
Dissipation Factor
<200% of maximum specified value
Leakage Current
<100% of maximum specified value
1000 hours at 105°C with no voltage applied
Capacitance Change
<25% initial measured value
Dissipation Factor
<200% of maximum specified value
Leakage Current
<100% of maximum specified value
Frequency (Hz)
Ripple Current Multipliers
Capacitance
C<180
220<C<560
680<C<1800
2200<C<3900
C>4700
50
.4
.5
.6
.75
.85
120
.4
.5
.6
.75
.85
1k
.75
.85
.87
.9
.95
10k
.9
.94
.95
.95
.98
100k
1.0
1.0
1.0
1.0
1.0
D
5
6.3
8
10
S
2.0
2.5
3.5
5.0
d
0.5
0.5
0.6
0.6
L
1
=L+1.5 mm Max. (L<20mm)
L
1
=L+2.0 mm Max. (L>20mm)
D
1
=D+0.5 mm Max.
S
1
=S+0.5 mm
12.5
5.0
0.6
16
7.5
0.8
18
7.5
0.8
mm
Feb-17
MC34063 or IRM03A automatic design software
MC34063 or IRM03A automatic design software...
gaoyanmei Test/Measurement
There are 10 digital tubes on a digital tube display board, which uses 1 74HC00D, 2 74HC04D and 10 74HC164D
There are 10 digital tubes on a digital tube display board, which uses 1 74HC00D, 2 74HC04D, 10 74HC164D, and 1 NE555P. How are these 4 types of chips used in combination? Please help analyze it...
深圳小花 PCB Design
Electronics Competition Works Simplex Wireless Calling System (the 7th National First Prize)
[i=s]This post was last edited by paulhyde on 2014-9-15 04:16[/i] [font=宋体][size=3]The simplex wireless calling system is divided into the sending part and the receiving part. The sending part is main...
fish001 Electronics Design Contest
Design of a warning system to prevent rear-end collision of automobiles
Abstract: This paper introduces the highway rear-end collision prevention warning system, which consists of an information collection unit, a central control unit, an alarm circuit and a display outpu...
guangqiji Automotive Electronics
How does stm32 read the values of R13 and R14?
It doesn't matter whether you use keil, iar or mixed programming, as long as you can access it!!!I want to write a multi-tasking program, but I can't even access SP!!!...
younghorse2012 stm32/stm8
Can the move vertices operation be performed in AD17.1?
I saw that some versions of AD can perform the move vertices operation, which means moving vertices to modify the shape of the copper. The shortcut key is EMG, but my AD17 does not have this option. W...
南山维拉 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 371  416  1242  2389  2196  8  9  26  49  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号