MIL–PRF (CWR Style) Established Reliability – T419 Series CWR19 Style MIL–PRF–55365/11
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
VDC
Rated
Cap
µF
3.3
4.7
6.8
10
15
22
22
33
33
47
68
100
150
220
330
3.3
4.7
6.8
10
15
15
15
22
22
33
47
68
68
100
150
220
330
2.2
3.3
4.7
4.7
6.8
6.8
6.8
10
10
10
10
15
15
22
33
47
47
µF
Case Code/
Case Size
KEMET/EIA
A/1005
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
D/1510
E/2010
E/2010
E/2010
F/2214
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
G/2711
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
C/2005
B/1505
C/2005
D/1510
B/1505
C/2005
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T419A335(1)004(2)(3)(4)
T419A475(1)004(2)(3)(4)
T419A685(1)004(2)(3)(4)
T419B106(1)004(2)(3)(4)
T419B156(1)004(2)(3)(4)
T419B226(1)004(2)(3)(4)
T419D226(1)004(2)(3)(4)
T419D336(1)004(2)(3)(4)
T419E336(1)004(2)(3)(4)
T419E476(1)004(2)(3)(4)
T419E686(1)004(2)(3)(4)
T419F107(1)004(2)(3)(4)
T419G157(1)004(2)(3)(4)
T419H227(1)004(2)(3)(4)
T419H337(1)004(2)(3)(4)
T419A335(1)006(2)(3)(4)
T419A475(1)006(2)(3)(4)
T419B685(1)006(2)(3)(4)
T419B106(1)006(2)(3)(4)
T419B156(1)006(2)(3)(4)
T419D156(1)006(2)(3)(4)
T419E156(1)006(2)(3)(4)
T419D226(1)006(2)(3)(4)
T419E226(1)006(2)(3)(4)
T419E336(1)006(2)(3)(4)
T419F476(1)006(2)(3)(4)
T419F686(1)006(2)(3)(4)
T419G686(1)006(2)(3)(4)
T419G107(1)006(2)(3)(4)
T419G157(1)006(2)(3)(4)
T419H227(1)006(2)(3)(4)
T419H337(1)006(2)(3)(4)
T419A225(1)010(2)(3)(4)
T419A335(1)010(2)(3)(4)
T419B475(1)010(2)(3)(4)
T419C475(1)010(2)(3)(4)
T419B685(1)010(2)(3)(4)
T419C685(1)010(2)(3)(4)
T419D685(1)010(2)(3)(4)
T419B106(1)010(2)(3)(4)
T419C106(1)010(2)(3)(4)
T419D106(1)010(2)(3)(4)
T419E106(1)010(2)(3)(4)
T419D156(1)010(2)(3)(4)
T419E156(1)010(2)(3)(4)
T419E226(1)010(2)(3)(4)
T419F336(1)010(2)(3)(4)
T419F476(1)010(2)(3)(4)
T419G476(1)010(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/11
Part Number
(See below for
part options)
CWR19C(3)335(1)(2)A(5)
CWR19C(3)475(1)(2)A(5)
CWR19C(3)685(1)(2)A(5)
CWR19C(3)106(1)(2)B(5)
CWR19C(3)156(1)(2)B(5)
CWR19C(3)226(1)(2)B(5)
CWR19C(3)226(1)(2)D(5)
CWR19C(3)336(1)(2)D(5)
CWR19C(3)336(1)(2)E(5)
CWR19C(3)476(1)(2)E(5)
CWR19C(3)686(1)(2)E(5)
CWR19C(3)107(1)(2)F(5)
CWR19C(3)157(1)(2)G(5)
CWR19C(3)227(1)(2)H(5)
CWR19C(3)337(1)(2)H(5)
CWR19D(3)335(1)(2)A(5)
CWR19D(3)475(1)(2)A(5)
CWR19D(3)685(1)(2)B(5)
CWR19D(3)106(1)(2)B(5)
CWR19D(3)156(1)(2)B(5)
CWR19D(3)156(1)(2)D(5)
CWR19D(3)156(1)(2)E(5)
CWR19D(3)226(1)(2)D(5)
CWR19D(3)226(1)(2)E(5)
CWR19D(3)336(1)(2)E(5)
CWR19D(3)476(1)(2)F(5)
CWR19D(3)686(1)(2)F(5)
CWR19D(3)686(1)(2)G(5)
CWR19D(3)107(1)(2)G(5)
CWR19D(3)157(1)(2)G(5)
CWR19D(3)227(1)(2)H(5)
CWR19D(3)337(1)(2)H(5)
CWR19F(3)225(1)(2)A(5)
CWR19F(3)335(1)(2)A(5)
CWR19F(3)475(1)(2)B(5)
CWR19F(3)475(1)(2)C(5)
CWR19F(3)685(1)(2)B(5)
CWR19F(3)685(1)(2)C(5)
CWR19F(3)685(1)(2)D(5)
CWR19F(3)106(1)(2)B(5)
CWR19F(3)106(1)(2)C(5)
CWR19F(3)106(1)(2)D(5)
CWR19F(3)106(1)(2)E(5)
CWR19F(3)156(1)(2)D(5)
CWR19F(3)156(1)(2)E(5)
CWR19F(3)226(1)(2)E(5)
CWR19F(3)336(1)(2)F(5)
CWR19F(3)476(1)(2)F(5)
CWR19F(3)476(1)(2)G(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Max/5 Min
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
3.0
4.0
6.0
8.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.8
4.0
4.0
6.0
10.0
10.0
20.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
3.0
3.0
4.0
4.0
µA @ +20ºC
Max/5 Min
DF
% @ 20ºC
120 Hz Max
6.0
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
6.0
8.0
6.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
% @ 20ºC
120 Hz Max
ESR
Ω @ +20ºC
100 kHz Max
12.0
12.0
12.0
8.0
8.0
8.0
4.0
4.0
3.0
3.0
3.0
2.0
1.0
1.0
0.9
12.0
12.0
8.0
8.0
8.0
5.0
3.0
5.0
3.5
3.5
3.5
1.5
1.0
1.1
1.1
0.9
0.9
12.0
12.0
8.0
5.5
8.0
5.5
5.0
8.0
5.5
4.0
3.5
5.0
3.0
2.0
1.5
1.5
1.0
Ω @ +20ºC
100 kHz Max
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated Cap
Case Code/
Case Size
KEMET Part Number
MIL–PRF–55365/11
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, C = -55°C +85°C before Weibull or Z = None. Designates Surge
current option.
Refer to Ordering Information for additional detail.
[size=4] What is dimension? It is usually taught in middle school physics courses and again in university physics courses. However, I am afraid that most students are still vague about dimension. [/si...
Please help me, I need to write a C++ program to send commands to vxworks, query the task execution, and return the results to the C++ program.How to achieve this? It would be best if there is code, t...
First of all, no matter what new project you create, you must include the following folders: 1. Code: This is where your code is stored; 2. SCH: This is where your schematics and PCB diagrams are stor...
In MSP430F5529, BCSCTL1 is a time register, but why does my IAR say this variable is undefined when compiling? I have added the header file, but I don't know why. I searched the header file and found ...
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]
Product series: PB-B-RS232/485 interface (hereinafter sometimes referred to as "interface") is a product in the PROFIBUS bus bridge series.
The main purpose of the bridge series ...[Details]
The automotive lighting and signal control system is responsible for controlling the vehicle's lighting, signal lights, electric horns, reversing and brake buzzers. Traditional automotive lighting...[Details]
The typical fault troubleshooting listed below is for reference of maintenance personnel.
When the computer is turned on, the indicator light is off and there is no screen display
Mainte...[Details]
Currently, each country is developing its own USB interface
charging specifications
, which leads to a major problem that a USB interface
charging
device manufactured in one country...[Details]
1 Introduction to LED
With the development of science and technology, people have higher and higher requirements on automobile light sources. LED (Light Emitting Diode) has gradually attracted...[Details]
Nowadays, more and more people have digital cameras. The convenience and speed of digital cameras have gradually replaced film cameras and become the main tool for people's daily photography. The n...[Details]
In recent years, with the increasing maturity of LED technology, LED light sources have been increasingly widely used due to their advantages of using low-voltage power supply, low energy consumpti...[Details]
1. Project Introduction
Beijing Benz-Daimler Chrysler Co., Ltd. is a joint venture between Beijing BAIC Group and Benz-Daimler Chrysler. In October 2005, it started to build a new automobile ...[Details]
Fairchild's FAN6208 is a synchronous rectification (SR) controller for isolated LLC or LC resonant converters that can drive two individual SR MOSFETs emulating the behavior of rectifier diodes. FAN62...[Details]
Traditionally, when using PLC to control stepper motors, a dedicated stepper motor control intelligent module is usually added to the PLC, and then connected to the drive power supply to realize th...[Details]
1. Introduction
Stepper motor is a basic component that converts electrical energy into kinetic energy. It has been widely used in a variety of electromechanical equipment, such as various machine...[Details]
Previously used primarily in high-power power supplies and large industrial and consumer power supplies, supercapacitors are now finding their way into products of all sizes, especially portable de...[Details]
Li/SOCl2 batteries (lithium sub-cells) have the advantages of high operating voltage, stable discharge voltage, wide operating temperature range and long storage life, and have been widely used in ...[Details]
First, the choice of charging location. Wireless charging technology is related to the distance and state of the charger and the charged device. That is to say, the distance between the two cannot...[Details]