PRODUCT INFORMATION
ÖLFLEX® CONTROL TM
ÖLFLEX® Control Cable PVC 0.6/1kV UL TC-ER WTTC AWM600V WET OIL RES I+II CSA AWM
ÖLFLEX® CONTROL TM: UL MTW TC-ER CIC WTTC AWM 600V OIL RES I+II WET, CSA AWM I/II A/B FT4, Power and
control cable 0.6/1 kV, PVC, Tray Exposed Run, Wind Turbine
Info
Torsion resistant for drip loops
Wide application range (NFPA 70/NEC)/ compliance with NFPA 79 for industrial machinery
(UL) SUN. RES. approval in preparation
Torsion-resistant
Oil-resistant
Mechanical resistance
Flame-retardant
Cold-resistant
Benefits
Wide application range due to multiple certifications
Cost-saving, easy installation due to omission of closed raceways (suitable for open wiring)
Last Update (22.11.2016)
©2016 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
PRODUCT INFORMATION
ÖLFLEX® CONTROL TM
Application range
Industrial machinery; plant engineering
Machine tools compliant with UL MTW (Machine Tool Wiring)
TC-ER (Tray Cable Exposed Run) approval for open wiring between cable tray and industrial machines/plants acc. to NEC
336.10(7)
Wind turbines: USA Wind Turbine Tray Cable (WTTC)
According to NEC/ NFPA 70 (2014), ARTICLE 501, for hazardous Class I, Division 2 locations determined in NEC ARTICLE
500
Product features
Flame-retardant according to CSA FT4
UL Vertical-Tray Flame Test
Oil-resistant according to UL OIL RES I & II
Water-resistant, UL 75°C wet rating
Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
Suitable for outdoor use thanks to technical UV and ozone resistance
Norm references / Approvals
Multi-standard cables have conductor strands with nominal sizes in mm²
or
AWG/kcmil. The master size is mentioned in the
table below, while the equivalent size of the other system can be found in the Appendix T16 of this catalogue. For this related
secondary size the cross-section of the conductor mostly works out to be greater than the
specified nominal value.
UL cable type certifications for US use:
- (UL) TC-ER per UL 1277 [UL file no.: E171371];
- (UL) MTW per UL 1063 [UL file no.: E155920];
- (UL) WTTC per UL 2277 [UL file no.: E323700];
- UL AWM styles 2587 & 21098 (Oil) per UL 758 [UL file no.: E100338].
Attributes:
- UL OIL RES I/ II;
- 75°C Wet, 90°C Dry;
- Technically sunlight resistant (not SUN. RES. certified);
- Direct burial;
- Bus Drop Cable (2.5 mm²/ 14 AWG and larger, 3-core and 4-core versions only);
- NFPA 79 2015 Edition;
- FT4 flame retardance.
NEC (NFPA 70):
- Class 1, Division 2 per NEC Article 501.
UL and CSA cable type certifications for use in Canada:
- c(UL) CIC/ TC FT4 [UL file no.: E171371];
- CSA AWM I/II A/B FT1;
- CSA C22.2 210.2.
Additionally:
- Impact and Crush test per UL 1277 (excluding 0.75 mm²)
Product Make-up
Fine-wire strand made of bare copper wires
Insulation: PVC with nylon sheath (PA skin)
Outer jacket: Specially Formulated Thermoplastic Polymer
Color of the outer jacket: Gray
Last Update (22.11.2016)
©2016 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
PRODUCT INFORMATION
ÖLFLEX® CONTROL TM
Technical Data
Classification:
ETIM 5.0 Class-ID: EC000104
ETIM 5.0 Class-Description: Control cable
Black with white numbers
Fine-wire, bare copper strand
TW-0 & TW-2, refer to Appendix T0
Static/Occ. moved: 5/15xOD*
UL/CSA: 600 V (TC, MTW, CIC), WTTC 1000 V
UL AWM: 600 V
CSA AWM: 1000 V
IEC U
0
/U: 600/1000 V
2000 V
G = with GN-YE protective conductor
X = without protective conductor
-40°C (static)/ -25°C (occ. moved) to +90°C (AWM: +105°C)
Core identification code:
Conductor stranding:
Torsion movement in WTG:
Minimum bending radius:
Nominal voltage:
Test voltage:
Protective conductor:
Temperature range:
Note
Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon
request.
Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related
surcharges.
Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
Please specify the preferred type of packaging (e.g. 1 x 610 m drum or 8 x 76 m coils).
Photographs are not to scale and do not represent detailed images of the respective products.
* Prices are net prices without VAT and surcharges. Sale to business customers.
*OD = Outer diameter
Last Update (22.11.2016)
©2016 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
Powered by TCPDF (www.tcpdf.org)
Powered by TCPDF (www.tcpdf.org)
ÖLFLEX® CONTROL TM
Article number
ÖLFLEX® CONTROL TM
281803
281804
281805
281807
281812
281818
281825
281602
281603
281604
281605
281607
281609
281612
281618
281625
281403
281404
281405
281407
281203
281204
281205
281207
281004
281005
280804
280805
280604
Number of cores and mm² per
conductor
3G1
4G1
5G1
7G1
12 G 1
18 G 1
25 G 1
2 X 1.5
3 G 1.5
4 G 1.5
5 G 1.5
7 G 1.5
9 G 1.5
12 G 1.5
18 G 1.5
25 G 1.5
3 G 2.5
4 G 2.5
5 G 2.5
7 G 2.5
3G4
4G4
5G4
7G4
4G6
5G6
4 G 10
5 G 10
4 G 16
Outer diameter (mm)
Copper index (kg/km)
Weight (kg/km)
Last Update (22.11.2016)
©2016 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16
7.4
8
8.6
9.3
12
14.7
16.7
7.3
8.1
8.8
9.5
10.3
11.9
14.1
16.4
18.6
8.9
9.8
10.7
11.6
10.6
11.5
12.6
14.6
14.5
15.8
17.7
19.4
22.5
28.8
38.4
48
67
115
173
240
28.8
43
58
72
101
129.6
172.8
259
360
72
96
120
168
115
154
192
269
231
288
384
480
615
82
95
112
144
247
365
464
74
100
119
141
183
247
328
403
596
125
155
185
244
165
220
269
482
382
457
615
771
864
PRODUCT INFORMATION