EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-119-57-0900

Description
Board Connector, 114 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size107KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

54122-119-57-0900 Overview

Board Connector, 114 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle

54122-119-57-0900 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerAmphenol
Reach Compliance Codecompli
body width0.19 inch
subject depth0.354 inch
body length5.7 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedTin/Lead (Sn/Pb) - with Nickel (Ni) barrie
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialTHERMOPLASTIC
JESD-609 codee0
Manufacturer's serial number54122
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness30u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts114
PDM: Rev:K
STATUS:
Released
Printed: Mar 10, 2011
.
Ask: After assigning a value to an integer in wince, the upper 3 bits are set to 0
Now I have a program that needs to assign a four-byte number, as follows int x = 0x12345678; but it is always set to 0x00345678. Can anyone tell me how to solve this? Thank you....
给我一个大苹果 Embedded System
Share two errors and solutions during DSP debugging
2 small problems, the solutions are as follows (1) Error Trouble Writing Register: Error 0x00000004/-1024 Error during: Register, PTI_ERR_PREV_IROP_CMD Error Occured at 0x00000000 Solution: Execute de...
Jacktang DSP and ARM Processors
How to detect network cable insertion in stm32
How can stm32 detect whether a network cable is plugged into the network port? That is, when a network cable is detected, the network is initialized, and when no network cable is plugged in, the netwo...
gaokushuai stm32/stm8
Why can the memory mapping under WinCE only be built to more than 400M?
I tested that if a single file is built 1M by 1M to create a memory mapping, it can build about 830M, which means that WinCE only has about 830M of memory mapping for the client area. Then I tested ho...
rose007 Embedded System
Common component pad graphics library
In order to facilitate the production of mounting, it is hoped that the zero-degree direction and positioning reference of the surface mount components are determined in the CAD library according to u...
qwqwqw2088 PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2671  651  200  395  1818  54  14  5  8  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号