EEWORLDEEWORLDEEWORLD

Part Number

Search

35YXG56MFA6.3X11

Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 35V, 20% +Tol, 20% -Tol, 56uF, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size192KB,3 Pages
Manufacturerrubycon
Websitehttp://www.rubycon.co.jp/cn/
Environmental Compliance
Download Datasheet Parametric View All

35YXG56MFA6.3X11 Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 35V, 20% +Tol, 20% -Tol, 56uF, Through Hole Mount, RADIAL LEADED, ROHS COMPLIANT

35YXG56MFA6.3X11 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Makerrubycon
package instruction,
Reach Compliance Codecompli
ECCN codeEAR99
capacitance56 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
diameter6.3 mm
dielectric materialsALUMINUM (WET)
JESD-609 codee3
leakage current0.0196 mA
length11 mm
Manufacturer's serial numberYXG
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
Package shapeCYLINDRICAL PACKAGE
Package formRadial
method of packingBulk
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)35 V
ripple current170 mA
seriesYXG
surface mountNO
Delta tangent0.12
Terminal surfaceTin (Sn)
Terminal pitch5 mm
Terminal shapeWIRE
MINIATURE ALUMINUM ELECTROLYTIC CAPACITORS
YXG
YXG
SERIES
105
o
C High ripple current. Long Life.
FEATURES
Low impedance at 100kHz with selected materials.
Load Life : 105℃ 3000∼6000hours.
RoHS compliance.
SPECIFICATIONS
Items
Category Temperature Range
Characteristics
-
40
+
105
°
C
6.3
100V.DC
Rated Voltage Range
Capacitance Tolerance
+
-
20% (20
°
C,
120Hz)
I=
0.01CV or 3
µA
whichever is greater.     (After 2 minutes)
Leakage Current(MAX)
I=
Leakage Current
(µA)
C=
Rated Capacitance
(µF)
V=
Rated Voltage
(V)
(20
°
C, 120Hz)
(tan
δ
)
Dissipation Factor(MAX)
Rated Voltage
6.3 10 16 25 35 50 63 100
(V)
tan
δ
0.22 0.19 0.16 0.14 0.12 0.10 0.09 0.08
When rated capacitance is over 1000
µF,
tan
δ
shall be added 0.02 to the listed value with increase of every 1000
µF.
After life test with rated ripple current at conditions stated in the table below, the capacitors shall meet the following requirements.
Capacitance Change
Dissipation Factor
Leakage Current
Rated Voltage
6.3
(V)
Z
-
25
°
C)(20
°
C) 4
/Z
°
C)(20
°
C) 8
Z
-
40
/Z
Within
Endurance
+
-
25% of the initial value.
Case Size
φ
D
<
6.3
=
φ
D
=
8
φ
D
=
10
φ
D
<
12.5
=
Not more than 200% of the specified value.
Not more than the specified value.
Life Time
(hrs)
3000
4000
5000
6000
10
3
6
16
2
4
25
2
3
35
2
3
50
2
3
63
2
3
100
2
3
(120Hz)
Low Temperature Stability
Impedance Ratio(MAX)
MULTIPLIER FOR RIPPLE CURRENT
Frequency coefficient
Frequency
Hz)
DIMENSIONS
SLEEVE
(mm)
±0.5
φD+0.5MAX
φd
6.8
33
µ
F
39
270
µ
F
Coefficient
0.42
0.50
0.55
0.60
0.70
0.70
0.73
0.77
0.80
0.85
0.90
0.92
0.94
0.96
0.98
1.00
1.00
1.00
1.00
1.00
L+
α
MAX
15MIN
4MIN
330
680
µ
F
820
1800
µ
F
2200
18000
µ
F
φ
D
φ
d
F
α
5
6.3
0.5
8
10
0.6
12.5
F
120
1k
10k
100k <
=
16
0.8
7.5
18
2.0
2.5
3.5
5.0
L
<
16 :
α
=
1.5 L
<
20 :
α
=
2.0
=
=
PART NUMBER
YXG
Rated Voltage
Series
Rated Capacitance
Capacitance Tolerance
Option
Lead Forming
D
×
L
Case Size
How to read circuit diagrams. Recommended resources: 1. Circuit diagram reading from entry to mastery
[align=center][size=5][b]How to read circuit diagrams. Recommended resources. 1. [color=rgb(0, 0, 0)][backcolor=rgb(237, 235, 235)][font=微软雅黑]Circuit diagram recognition from entry to mastery[/font][/...
tiankai001 Download Centre
Can anyone tell me how to implement Fn+Fx on a laptop?
I only know that Fn+Fx will generate a Scancode, but if the ScanCode is defined the same on different keyboards, how can I know which ScanCode is sent when pressing Fn+Fx? Environment: XP Sp2/Vista Sp...
hahatoday Embedded System
Sampling of differential circuits
I'm working on something related to electric energy measurement recently. When collecting voltage and current signals, someone suggested using a differential circuit. Why can't we just do voltage divi...
xiaodanbao Test/Measurement
My opinion on Easy Power Supply
When we design power supplies, especially when powering circuit boards, the most commonly used and most reliable method is: control transformer + 78xx (or 79XX). The reason is very simple. The control...
aoxiaoche918 Analogue and Mixed Signal
Could you please help me, it's not difficult for you.
1. The mileage pulse signal is input from external 0 (INT0). For each pulse signal, the system adds 0.1km and records the mileage. 2. The interrupt method of timer Tx is used to achieve 10s timing (bu...
919202089 51mcu
Ask a question about calling the library function of the CAN module
Have you ever used the CAN module of the TM4C series microcontroller? When entering an interrupt, you need to read the CANINT register, right? It is used to determine the current interrupt source. How...
shiqiaocanxue Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1104  1143  768  1171  23  23  24  16  1  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号