EEWORLDEEWORLDEEWORLD

Part Number

Search

A1DYKJ14E1

Description
A1DYKJ14E1
CategoryPassive components    The resistor   
File Size174KB,8 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

A1DYKJ14E1 Overview

A1DYKJ14E1

A1DYKJ14E1 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSCHURTER
Reach Compliance Code_compli
ECCN codeEAR99
3
CIRCUIT BREAKERS FOR EQUIPMENT
TA45: 3 pole, rocker actuated
• Thermal release
• Positively trip-free
The rocker actuated, 3 pole version with 2 protected poles is a
thermal CBE of the TA45 line, specifically designed to provide cost
effective protection of 3 phase motors against overheating in
accordance with EN60204 Part I (Electrical equipment for industrial
machines) in cases where the exception specified in this standard is
applicable.
A special version is available as a «CBE-switch», in which the means
for automatic overcurrent interruption (the bimetal releases), are
omitted.
Another available version of this line utilizes an under-voltage release
to protect persons against injuries caused by unexpected events like
the automatic restarting of motors after a power failure. This release
can be combined with the thermal release required for overcurrent
protection. Protection against injuries is also provided by another CBE
of this line, which prevents the starting of a machine should a
protective cover be removed from dangerous parts of the machine.
Available options:
• CBE for overcurrent protection
2 protected poles (thermal)
• CBE with undervoltage release:
The CBE will open automatically when the voltage drops
below the trip level. Only when the supply voltage has reached
the reset level, the CBE can be re-closed manually.
• CBE switch with mechanical lock-out latch:
A spring loaded pin will trip the CBE if a protective cover is
removed. The CBE can not be switched ON until the
protective cover is refitted.
• CBE with remote trip release:
The remote trip release permits the CBE to be tripped by a
external contact (sensor) energizing the trip coil.
• CBE with auxiliary contact:
All types of the line can be with an auxiliary contact
(changeover contact).
TA45 is positively trip-free. The approved current range is 0,1 to 12A.
We recommend to limit the current range to max. 8A at AC 400V.
For the current range 9 to 12A the voltage should be limited to AC
240V. The CBE comes with snap-in mounting. The rocker is available
in various colors and also with illumination. It is approved in all major
industrial countries and complies with the CBE-standard EN60934. In
conjunction with its accessories the TA45 product line of Schurter
paves the way for new unconventional applications.
Applications
Motors
Power supplies
Processing machines
etc.
254
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 •
E-mail info@schurterinc.com •
Website http://www.schurterinc.com
Phone 707-778-6311 • Fax 707-778-6401 E-mail info@schurterinc.com Website http://www.schurterinc.com
TI C6000 Optimization Manual - Make Code Look Like Nails
[color=#000000]The emergence of DSP chips is to solve a large number of digital computing problems. By integrating dedicated adders, multipliers, address generators, complex logic and other hardware u...
Jacktang Microcontroller MCU
RIGOL's trade-in event has begun. Participants can also participate in the lucky draw to win an iPad!
[font=微软雅黑][size=4]RIGOL's trade-in event has begun. Participants can also take part in a lucky draw to win an iPad! {:1_108:}[/size][/font] [font=微软雅黑][size=4]For details of the event, please see: [u...
EEWORLD社区 Integrated technical exchanges
POE-level DC-DC power supply IC
Basically, it is a power supply IC for POE switch products with an input upper limit of 55V and an output that can be adjusted to a minimum of 1.8V. Standard packages such as SOP-8 or DIP-8 are being ...
小潜艇 Power technology
Are there any consumer electronics products that use ARM with VFP? For example, MP3, MP4, etc.?
VFP, that floating point thing... I want to make one to use as a learning board......
shanqiubin ARM Technology
If you leave your current company one day, what will be the reason?
Generally speaking, the key factors for leaving a company are concentrated in the following aspects: 1. The degree of trust that the leader has in employees; 2. The fairness of compensation; 3. The nu...
liuceone Talking
A collection of errata for "MCU Engineer's Trial"
1. "MCU Engineer's Trial" P75 Digital IO Program Suggestions [url]https://bbs.eeworld.com.cn/forum.php?mod=viewthread&tid=418514&fromuid=415653[/url] 2. "MCU Engineer's Trial" Printing Error 2 [url]ht...
qinkaiabc Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1345  1133  593  1549  232  28  23  12  32  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号