5400FE Non-Paired - Commercial Audio Systems - 2 Conductors Cabled
For more information please
call
1-800-Belden1
See Put-ups and Colors
Description:
20 AWG bare copper conductors, PVC insulation, conductors cabled, Beldfoil® shield tape (foil side out) with drain wire, PVC jacket with
ripcord, sequential footage marking every two feet.
SUITABLE APPLICATIONS:
Suitable Applications
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Conductors
Total Number of Conductors
AWG
Stranding
Conductor Material
INSULATION:
Insulation Material
Nom. Insulation Wall Thickness
OVERALL CABLING:
Overall Cabling Lay Length
Overall Cabling Twists/ft.
Overall Cabling Color Code Chart :
Number
1
OUTER SHIELD:
Outer Shield Material Trade Name
Outer Shield Type
Outer Shield Material
Outer Shield %Coverage
Outer Shield Drain Wire AWG
Outer Shield Drain Wire Stranding
Outer Shield Drain Wire Conductor Material
OUTER JACKET:
Page 1 of 3
Intercom/PA Systems, Sound/Audio Systems
2
2
20
7x28
BC - Bare Copper
PVC - Polyvinyl Chloride
.010 in.
3.0 in.
4.0
Color
Black
Number
2
Color
Red
Beldfoil®
Tape
Aluminum Foil-Polyester Tape w/Shorting Fold
100 %
22
7x30
TC - Tinned Copper
5400FE Non-Paired - Commercial Audio Systems - 2 Conductors Cabled
Outer Jacket Material
Outer Jacket Nominal Wall Thickness
Outer Jacket Ripcord
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
UL Temperature Rating
Bulk Cable Weight
Max. Recommended Pulling Tension
Min. Bend Radius (Install)
PVC - Polyvinyl Chloride
.015 in.
Yes
.145 in.
-20°C To +75°C
75°C
15.6 lbs/1000 ft.
37.1 lbs.
1.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
NEC Articles
CEC/C(UL) Specification
EU CE Mark (Y/N)
EU RoHS Compliant (Y/N)
EU RoHS Compliance Date (mm/dd/yyyy):
FLAME TEST:
UL Flame Test
C(UL) Flame Test
PLENUM/NON-PLENUM:
Plenum (Y/N)
Plenum Number
ELECTRICAL CHARACTERISTICS:
Nom. Inductance
Nom. Capacitance Conductor to Conductor @ 1 KHz
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz
Nom. Conductor DC Resistance @ 20 Deg. C
Nominal Outer Shield DC Resistance @ 20 Deg. C
Max. Operating Voltage - UL
Max. Recommended Current
.17 µH/ft
56 pF/ft
101 pF/ft
10.3 Ohms/1000 ft
11.2 Ohms/1000 ft
300 V RMS
3.75 Amps per conductor @ 25°C (10°C rise in temp)
N
6400FE
UL1666 Vertical Shaft
FT4
CMR
800
CMG
Yes
Yes
04/01/2005
PUT-UPS AND COLORS:
Item
Description
5400FE 0081000
2 #20 PVC FS
FRPVC
Put-Up (ft.)
1000
Ship Weight (lbs.)
17
Page 2 of 3
Jacket Color
GRAY
Notes
C
5400FE Non-Paired - Commercial Audio Systems - 2 Conductors Cabled
5400FE 008500
5400FE 008C500
5400FE 008U1000
5400FE 008U500
2 #20 PVC FS
FRPVC
2 #20 PVC FS
FRPVC
2 #20 PVC FS
FRPVC
2 #20 PVC FS
FRPVC
500
C500
U1000
U500
8.5
8
17
9
GRAY
GRAY
GRAY
GRAY
C = CRATE REEL PUT-UP.
Revision Number: 1
Revision Date: 10-05-2005
© Copyright 2006 Belden, Inc
All Rights Reserved.
Although Belden ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and
specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment
For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan-
2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU
ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb-
2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the
Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information
provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product
itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory
information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations
based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3