U539N-H20003-150PA

Description
Peizoresistive Sensor, Absolute, 0Psi Min, 150Psi Max, 0.1%, 0.5-4.5V, Cylindrical
CategoryThe sensor   
File Size319KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

U539N-H20003-150PA Overview

Peizoresistive Sensor, Absolute, 0Psi Min, 150Psi Max, 0.1%, 0.5-4.5V, Cylindrical

U539N-H20003-150PA Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTE Connectivity
Reach Compliance Codeunknow
Maximum accuracy(%)0.1%
Other featuresPort Height = 15.6 MM
body height64.9 mm
Body length or diameter24 mm
Maximum working current5 mA
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0.5-4.5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port typeG3/8 JIS B2351
Maximum pressure range150 Psi
Minimum pressure range
Pressure sensing modeABSOLUTE
Sensor/temperature sensor typePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage30 V
Minimum supply voltage5 V
Termination typeCABLE
U5300
Industrial Pressure Transducer
SPECIFICATIONS
Superior Accuracy and Total Error Band
Instrument Grade and Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Absolute, Compound
Expedite Configurations Available (10 Days)
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.1% Accuracy
±0.5% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The instrument grade U5300
pressure transducers from the UltraStable line
of MEAS, with their modular design, offer maximum flexibility for different
configurations. This latest series features superior accuracy and total error
band for demanding commercial and heavy industrial applications. This
series is suitable for measurement of liquid or gas pressure, even for difficult
media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 316L stainless steel and the transducer’s
durability is excellent with no O-rings or organics exposed to the pressure
media. The U5300 is weatherproof and exceeds the latest heavy industrial
CE requirements including surge protection. The circuit is protected from
reverse wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS
stands ready to provide a custom design of the U5300 where the volume and
application warrants. Additional configurations not listed are either available
or possible. Please inquire for further information.
APPLICATIONS
Military/Aerospace Test Stands
Automotive Test Stands
Calibration Equipment
High Accuracy Applications
Stationary Motor Fuel Control
High End Industrial Machinery
SENSOR SOLUTIONS
///U5300
07/2018
Page 1
Upgrading bootloader failed, check the short-circuit interfaces and study again
Continuing from the previous post, KW41Z's Best Partner - [NXP Kinetis MCU] - Electronic Engineering World Forum [url]https://bbs.eeworld.com.cn/thread-529560-1-1.html[/url] According to Freescale's u...
suoma NXP MCU
Can I add components to the vxsim simulation environment? How to configure vxworks
How to include INCLUDE_POSIX_SCHED when using POSIX functions in vxsim simulation environment? If the project (downloadable) is not selected, can the project not select component configuration? Is the...
taoym101 Real-time operating system RTOS
How to understand "everything is a file"? Answer from the perspective of the application layer and the driver layer.
Dear experts, how do you understand "everything is a file"? Please answer from the perspective of the application layer and the driver layer....
zhengjiewen Linux and Android
[Design Tools] This document introduces the FPGA operation steps for a certain function using ISE10.1
The document introduces the steps of using ISE10.1 to perform FPGA operations for a certain function, including the steps of creating a new document, synthesis, functional simulation, compilation and ...
GONGHCU FPGA/CPLD
The LPC2138 P1 port connected to the 1602 LCD simulation in Pretous cannot display! !
I am building a virtual simulation platform in Proteus. When using LM1602, the sent data cannot be displayed normally. I have successfully used the same code in the P0 port of LPC2106. Because there a...
chengchuanqing Embedded System
After the layer is locked, Blt returns DDERR_SURFACEBUSY. Who returns it?
Is there any lock when executing Blt? If yes, where is it added? There is no lock in HalBlt. When the layer is locked, the Blt operation directly returns DDERR_SURFACEBUSY without entering HalBlt oper...
friday505 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2123  805  882  1787  126  43  17  18  36  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号