BNS250-11ZG-2205 Overview

Coded-Magnet Sensors

SERIES BNS250
Coded-Magnet Sensors
Features & Benefits
• Compact size
… ideal for limited space applications.
• Sealed for submersibility
… assures long-term reliability
in the most hostile environments.
• Tamper-resistant
… cannot be bypassed with simple
magnets.
• Rugged, corrosion-resistant housing
… tolerates most
industrial environments.
• Integral LED status indicators
… facilitate easy
installation and provide visual indication of switch status.
• Shock and vibration tolerant
… designed to withstand
mechanical abuse.
• Satisfy CE & fail-to-safe requirements
… when used with
Series AES safety controllers.
Description
The Series BNS250 coded-magnet sensors are designed for
use as a safety interlock switch on movable machine
guards/articulating robot arms. Each sensor set consists of a
multiple reed switch unit and a coded-magnet actuator. The
reed switches, wired in series, will only close in the presence
of their matched magnetic field array.
Both switch and magnet assemblies are sealed to IP67
(submersible) standards. Their tamper-resistant design
prevents bypassing with a simple magnet or improperly coded
magnetic field. In addition, the BNS module features a 1-
meter long prewired pigtail.
AVAILABLE STANDARD MODELS
(Please order BPS250 magnet separately)
Part Number
BNS250-11z
BNS250-12z
BNS250-11zG
BNS250-12zG
Contact
Configuration*
1 NO & 1 NC
1 NO & 2 NC
1 NO & 1 NC
1 NO & 2 NC
Description
Multiple reed switch
(24VDC/100mA) assembly
with 1-meter prewired
pigtail
Multiple reed switch
(24VDC/10mA) assembly
with 1 meter prewired pigtail
and built-in LED display
Multiple reed switch
(24VDC/10mA) assembly with
1 meter pigtail (side entry) and
built-in LED display
Coded-magnet actuator
Operation
The reed switch assembly is typically mounted to a stationary
portion of a guard structure, with the coded-magnet assembly
mounted to the movable element of the machine guard. When
the guard is closed, and the matched magnetic field aligns
with the reed switch unit, the switches will close. When the
guard is open, or the required magnetic-field array is not
properly aligned with the reed switch assembly, the sensor
output will remain “off.”
BNS250-11zG-2205
1 NO & 1 NC
BPS250
N/A
*Contact configuration in presence of BPS250 coded-magnet
actuator.
Typical Applications
The sealed, compact BNS250 is ideal for use on movable
machine guards in hostile environments. Typical applications
include food processing equipment, chemical processing
equipment, woodworking machinery, packaging machinery,
and articulating robot arm rest position sensing.
*Important Note:
Series BNS Coded-magnet sensors are for use
in safety applications only when used with a
SCHMERSAL Series AES safety controller.
(Please see selection chart on Page 130.)
!
"
USE WITH ANY OTHER SAFETY CONTROLLER MAY
DAMAGE SENSOR AND/OR VOID WARRANTY.
114

BNS250-11ZG-2205 Related Products

BNS250-11ZG-2205 BNS250 BNS250-11Z BNS250-11ZG BNS250-12Z BNS250-12ZG BPS250
Description Coded-Magnet Sensors Coded-Magnet Sensors Coded-Magnet Sensors Coded-Magnet Sensors Coded-Magnet Sensors Coded-Magnet Sensors Coded-Magnet Sensors

Recommended Resources

Troubleshooting for TV that cannot be turned on
An old 32 Skyworth LCD TV suddenly couldn't turn on one day. The power light was yellow after it was powered on, and it should turn blue after it is normally lit! It couldn't turn on before! After rep...
DIAG Integrated technical exchanges
About usb SCSI protocol driver
Hello everyone~ _ ~! Has anyone worked on SCSI protocol? To implement external storage devices such as USB flash drives... This protocol is very complicated. If it is implemented on a USB HOST, how do...
dww12304106 Embedded System
Please teach me how to test function performance, experts are always online, waiting for your advice! ! ! ! ! !
I would like to ask what method can be used to test the actual running time and memory usage of a function under Linux. The C program under Linux should be similar to the normal TC program. The enviro...
simonblade Embedded System
Display bmp picture below EVC
RT which big brother has the reference code, send it to me, the points are not much, I will definitely give...
dfx168 Embedded System
Can anyone recommend a DC-DC converter that can boost voltage to 5V using two batteries?
[color=#000000]Recently, I am working on a remote control device and a smart switch for smart home. The wireless module uses an ordinary superheterodyne transmitter module, and the remote control uses...
analog010 Power technology
Has anyone used Winbond's 78E516B to make a serial port transceiver? Please help.
I am now using Philips' p89c669 to communicate with Winbond's w78e56b. The function implemented is: p89c669 sends a string of 24-byte commands, and w78e516b returns a command to p89c669 after receivin...
pilot Embedded System

Popular Articles

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 952  307  1360  1459  714  20  7  28  30  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号