EEWORLDEEWORLDEEWORLD

Part Number

Search

LCS051T05ZB24DC

Description
SNAP ACTING/LIMIT SWITCH, SPDT, MOMENTARY, 5.2mm, PANEL MOUNT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size229KB,4 Pages
ManufacturerC&K
Environmental Compliance  
Download Datasheet Parametric View All

LCS051T05ZB24DC Overview

SNAP ACTING/LIMIT SWITCH, SPDT, MOMENTARY, 5.2mm, PANEL MOUNT, ROHS COMPLIANT

LCS051T05ZB24DC Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompli
ECCN codeEAR99
Actuator stroke5.2 mm
Actuator typeSHORT LEVER
body width6.4 mm
body height15.95 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Manufacturer's serial numberLCS
Installation featuresPANEL MOUNT
Maximum operating force1.47 N
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Maximum pre-travel4.3 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeWIRE
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 125/250 V AC
and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE: –40ºC to +125ºC without wire
–40ºC to +85ºC with wires
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Models Available
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 125/250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
0.45 mm short lever
T05
5.05 mm short lever
T07
7.05 mm short lever
T13
13.15 mm lever
T19
20.95 mm lever
T28
28.35 mm lever
T43
43.55 mm lever
S26
6.25 mm simulated lever
A05
4.85 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
Let the digital tube display different numbers
I'm a beginner Want to know how to make 8 digital tubes display different numbers at the same time My microcontroller does not have a latch. It's best to write a program and see Thanks...
670357298 Buy&Sell
Does anyone know the difference between uCOS-II and CoOS?
As the title says. I know a little about CoOS, but I haven't seen uCOS-II. CoOS is free and open source for commercial or teaching use, but I don't know what uCOS-II is like? Is there any expert who c...
1LoveARM Real-time operating system RTOS
Post some jokes to make everyone relax
Firefly was detained for being a hooligan, but he refused to accept it: Who was giving off electricity? Who was streaking? Who has an exhibitionist fetish? The toilet is dark and I am not allowed to t...
Narachu Talking
Please help with the following procedure
static void vSwap_Flashes (void) { UINT32 ui32a; UINT32 ui32b; ui32a = GLOB_prImp->br0; ui32b = GLOB_prImp->br1; GLOB_prImp->br0 = ui32b; GLOB_prImp->br1 = ui32a; ui32a = GLOB_prImp->or 0; ui32b = GLO...
holystw Embedded System
CPLD dual integral AD analog-to-digital conversion help
Dear experts, this is a dual-integration AD circuit for analog-to-digital conversion. The left in is the voltage to be measured, 0 to -5V negative value, the right three are the comparator inputs to t...
244141084 Analog electronics
High-quality C language tutorial
High-quality C language...
single MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2028  2219  733  2611  587  41  45  15  53  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号