EEWORLDEEWORLDEEWORLD

Part Number

Search

L22-B2-22-410-42B-DG

Description
Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size2MB,8 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

L22-B2-22-410-42B-DG Overview

Magnetic Circuit Breaker,

L22-B2-22-410-42B-DG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompli
Circuit protection typeMAGNETIC CIRCUIT BREAKER
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
MVP's "wonderful answer"
I asked a question about MFC in the Microsoft forum, and an MVP answered like this: MFC under WinCE has many problems and can easily cause memory leaks. It is recommended not to use it as much as poss...
zxinqiao Embedded System
About the drift of vxworks time
The project found a problem. After setting the timer for 24 minutes, it was triggered at different times between 24 and 35 minutes. I found the following code. Please advise. word32 delay. word32 newD...
davidlee2046 Real-time operating system RTOS
Linux Basics
First upload 4 chapters, about the basic programming of Linux:), while learning from each other, please give me some points:pleased:,,,...
刘程 Linux and Android
Ten PLCs detect heater disconnection circuit diagram
[attach ]530140[/attach]...
uyuway Industrial Control Electronics
About the uniformity of sensor module sockets
I am currently working on an IoT project. Various sensor modules may be connected to the microcontroller, but the board cannot be made very large. I would like to ask you to recommend a few sensor mod...
e9996 stm32/stm8
74LS161 100-way frequency division
74ls161 has 100 frequency division. The principle is no problem, but after the circuit is soldered, it completely plays the role of frequency division, and the waveform is still very fuzzy. Please giv...
zrar Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1754  2689  4  1345  280  36  55  1  28  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号