EEWORLDEEWORLDEEWORLD

Part Number

Search

SFA37S2K156J-F

Description
CAPACITOR, METALLIZED FILM, POLYPROPYLENE, 2uF, CHASSIS MOUNT, CAN, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size742KB,5 Pages
ManufacturerCDE [ CORNELL DUBILIER ELECTRONICS ]
Environmental Compliance  
Download Datasheet Parametric View All

SFA37S2K156J-F Overview

CAPACITOR, METALLIZED FILM, POLYPROPYLENE, 2uF, CHASSIS MOUNT, CAN, ROHS COMPLIANT

SFA37S2K156J-F Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCDE [ CORNELL DUBILIER ELECTRONICS ]
package instruction,
Reach Compliance Codecompli
ECCN codeEAR99
Other featuresRATED AC VOLTAGE (V): 370
capacitance2 µF
Capacitor typeFILM CAPACITOR
dielectric materialsPOLYPROPYLENE
high39.624 mm
JESD-609 codee3
length54.864 mm
Manufacturer's serial numberSF
Installation featuresCHASSIS MOUNT
negative tolerance10%
Number of terminals2
Maximum operating temperature70 °C
Minimum operating temperature-40 °C
Package shapeRECTANGULAR PACKAGE
Package formQuick Connec
positive tolerance10%
Rated (AC) voltage (URac)370 V
seriesSF
surface mountNO
Terminal surfaceTin (Sn)
Terminal shapeBINDING POST
width33.274 mm
Type SF
Motor-Run and Power Supply Capacitors
Oil Filled/Impregnated, AC Rated, Metallized Polypropylene Capacitors
Type SF, AC rated metallized polypropylene capacitors pro-
vide starting torque and power factor correction for split
phase motors typically used in refrigeration and air condi-
tioning motor-run applications. Type SF also may be used
to provide noise suppression, voltage regulation and line
current reduction in power supply applications.
Highlights
Specifications
Self healing
Fault Current Protection up to 10,000 amps AFC
Low energy consumption
4 - tine, 1/4" quick connect lug terminals are standard
Meets EIA Standard EIA-456-A
UL recognized File Number E71645
CSA File Number 223507
Capacitance Range:
Voltage Range:
Capacitance Tolerance:
Temperature Range:
Dissipation Factor:
5.0 µF to 120.0 µF
240 Vac to 660 Vac
±10% standard, ± 6% and ±3% available
–40 ºC to 70 ºC standard, 90 º C available
<0.1%
Service Life Objective
The service life objective for this series is 60,000 hours of
operating life with a 94% survival rate when operated at full
voltage, 60 Hz, and rated ambient temperature. AC
capacitors are frequently used at voltages and ambient
temperatures other than rated conditions. Service life may
be estimated under specific conditions of temperature and
voltage by using the curves as shown
below and
to the right.
Capacitance vs. Temperature
The Capacitance vs. Temperature curve may be used to
determine the capacitance change as a function of
temperature. capacitance varies by no more than ±3 % over
the operating temperature range.
Capacitance vs. Temperature
Capacitance Change %
4
2
0
–2
–4
–6
–40
–20
0
20
40
60
80 100
Life vs. Temperature
100000
10000
1000
100
10
0
25
50
75
100
125
% of Rated Life
Temperature °C
Life vs. Voltage
% of Rated Life
% of Rated Temperature
1.002
% of Rated Voltage
Cornell Dubilier
1605 E. Rodney French Blvd.
New Bedford, MA 02744
Phone: (508)996-8564
Fax: (508)996-3830
www.cde.com
What is the function of adding common mode inductor in front of 2596?
I want to ask what is the purpose of adding common-mode inductance in front of 2596, and why do we need to add 400V/0.1UF capacitors before and after the common-mode inductance?...
sky999 Power technology
Single point grounding, DRC error
After the different ground GND and AGND are connected at a single point, it is easy to cause the copper to be re-clad and the single point to be disconnected. If the DRC prompt is not disconnected, ho...
刘木木 PCB Design
How does the IoT protocol help the development of the IoT industry?
The Internet of Things (IoT) is a field of development in communication technology. The annual growth rate of the IoT market is expected to reach nearly 457 billion by 2020. According to statistics, t...
兰博 RF/Wirelessly
Source (current source) Sink (current sink) detailed explanation
[size=4]An important premise: sink current and pull current are for ports, and both are for IC output ports. [/size] [size=4] [/size] [size=4]Term explanation - Sink: inject, fill, from outside to ins...
Jacktang Analogue and Mixed Signal
Input and output data to files when writing testbench
-- Copyright (C) 1991-2005 Altera Corporation-- Your use of Altera Corporation's design tools, logic functions -- and other software and tools, and its AMPP partner logic-- functions, and any output f...
eeleader-mcu FPGA/CPLD
Damping Oscillations in Switching Power Supplies
Netizen [aq1261101415] posted a post titled "Switching Power Supply Waveforms" , which talked about the waveforms at both ends of the switch tube in the intermittent state of the flyback current, and ...
maychang Switching Power Supply Study Group

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1795  348  217  2483  2788  37  7  5  50  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号