EEWORLDEEWORLDEEWORLD

Part Number

Search

3062-104-3001

Description
Board Connector, 4 Contact(s), 1 Row(s), Male, Straight, 0.156 inch Pitch, Solder Terminal, Natural Insulator, Receptacle
CategoryThe connector    The connector   
File Size153KB,1 Pages
ManufacturerMethode Electronics Inc.
Download Datasheet Parametric View All

3062-104-3001 Overview

Board Connector, 4 Contact(s), 1 Row(s), Male, Straight, 0.156 inch Pitch, Solder Terminal, Natural Insulator, Receptacle

3062-104-3001 Parametric

Parameter NameAttribute value
MakerMethode Electronics Inc.
Reach Compliance Codeunknow
ECCN codeEAR99
Other featuresWITH HOOKS
Board mount optionsPCB EDGE LOCKING HOOK
subject depth0.45 inch
body length0.618 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedGOLD OVER NICKEL
Contact point genderFEMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact resistance5 mΩ
Contact styleSQ PIN-SKT
DIN complianceNO
Dielectric withstand voltage1500VAC V
Filter functionNO
IEC complianceNO
maximum insertion forceLIF N
Insulation resistance500000000000 Ω
Insulator colorNATURAL
insulator materialNYLON
JESD-609 codee4
MIL complianceNO
Plug contact pitch0.156 inch
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number1
Number of rows loaded1
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
Plating thickness15u inch
polarization keyPOLARIZED HOUSING
Rated current (signal)7 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.125 inch
Terminal pitch3.96 mm
Termination typeSOLDER
Total number of contacts4
UL Flammability Code94V-0
Evacuation force-minimum valueLIF N
.156” (3.96mm)
Through Hole Vertical Mount Connector
3000 SERIES “TERMACON”
PART NUMBER LEGEND
30XX-XXX-XXXX
CONTACT TAIL DIMS (SEE TABLE 2)
CONTACT MATERIAL (SEE NOTE 1)
OPTIONS
2 - HIGH INSERTION FORCE CONTACT
3 - LOW INSERTION FORCE CONTACT
NO. OF POSITONS (SEE TABLE 1)
OPTIONS
0-
1-
3-
6-
7-
8-
WITH LEGS
WITH HOOKS
WITH HOOKS AND LOCKING RAMP
WITH LOCKING RAMP
WITH HOOKS, LOCKING RAMP AND POLARIZING KEY
WITHOUT HOOKS, W/ LOCKING RAMP AND POLARIZING KEY
CONTACT FINISH (SEE NOTE 2)
INSULATOR MATERIAL (SEE NOTE 1)
MATING HEADERS: 3100 SERIES
HOLE
LEG
LOCKING
RAMP
POLARIZING KEY &
LOCKING RAMP
Connector Products
1700 Hicks Road • Rolling Meadows, IL 60008 USA
Telephone: 847.392.3500 • Fax: 847.392.9404
email: mcpsales@methode.com • Web Page: www.methode.com
LIS3DH sensor high-pass filter question and data refresh rate consultation
I am currently debugging the LIS3DH three-axis acceleration sensor and have come across a few issues. I would like to ask the experts about the main application scenarios: I am going to use this senso...
yanghaii MEMS sensors
Anti-collision mechanism for RFID multi-tag reading
Under normal circumstances, an RFID reader can only read or write one RFID card in the magnetic field at a time. However, in actual applications, multiple cards often enter the reader's radio frequenc...
Jacktang RF/Wirelessly
[GD32L233C-START Review] 11. DAC output voltage value_ADC reads external voltage value
[i=s]This post was last edited by hehung on 2022-2-12 14:25[/i]For previous posts, please refer to:【GD32L233C-START Review】1. Unboxing [GD32L233C-START Review] 2. Create a new project step by step [GD...
hehung GD32 MCU
How to make arm serial port 1 receive data.
I have a question. My test board's serial port 1 is used as a command communication port. Now I use serial port 1 for testing and use remote telnet to log in for debugging. The serial port 1 data is s...
action99 ARM Technology
Protel99se has the problem of code not found again
I checked it several times and it always says there is something wrong with R1-16. But R1 only has pins 1 and 2, not 16. Can anyone tell me what is wrong?...
justsuperone PCB Design
How can I implement the function of exiting a subroutine in an interrupt?
For example, if I need to terminate the current subroutine in a port interrupt, how should I achieve it?...
echoyang Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1412  567  668  1749  127  29  12  14  36  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号