Single-phase, primary switched mode power supply
PVSA 230/30-3
Advantages
Stabilised and adjustable output voltage
Up to 200 % Real Power Boost for 4 seconds
Top Boost to trip conventional circuit breakers
DC OK signalling via LEDs
Parallel connection option
Service-friendly spring-loaded connector system
Optional with active inrush current limiter
Panel installation on mounting rails
Compatible to AS-i
Applications
Primary switched mode power supply with integrated output filter for AS-i bus
system.
Picture shows PVSA 230/30-3
Standards
Z
Approvals
J y
Z
Primary switched mode power supply
to UL 60950, UL 508
Safety:
EN 60950, EN 60950 (SELV), EN 60204 (PELV)
EMC:
EN 55022 (Interference emissions), EN 61000-4-3 (Interference immunity)
Single-phase, primary switched mode power supply
PVSA 230/30-3
Type
Special features
PVSA 230/30-3
Compatible to AS-i
100 – 240 Vac
85 - 264 Vac (120 - 350 Vdc)
5%/Vac < 95 Vac
700 ms
Varistor
1,13/0,7 Aac (100 Vac/ 240 Vac)
0,68
<30 A
4 AT
50 Hz – 60 Hz
6 A, 10 A, 16 A,
characteristic B, C
typ. 80 ms @230 Vac
30,5 Vdc
29,0 - 32,0 Vdc
50 Vdc
3.00 A
6 A / 4 s (4,5 A / 8 s)
18 Adc for 25 ms
Constant current
Yes
7,3 W / 20 W
82.0 %
typ. 1 ms
typ. 1,1 x Inenn
1 mA
LED green: Uout > 0,85 x Unenn; LED red: off
–10 °C … +70 °C
–25 °C … +85 °C
-3 %/K > +50 °C
0 mm
Natural convection
70 mm
IP 20
I
PV-CON (optional)
PVSA 230/30-3
Type
30
PVSA 230/30-3
WAGO series 231, max. 2,5 mm²
WAGO series 231, max. 2,5 mm²
DIN rail mounting
1.16 kg
Terminal and mounting
Terminals Input
Terminals Output
Fixing method
-
+
Characteristics
Input
Input rated voltage
Input voltage range
Input voltage derating
Switch-on time
Transient surge voltage protection
Input rated current (rated load)
Power factor
Starting current limiter
Input fuse internal
Frequency Range
Recommended back-up fuse (circuit breaker)
Mains buffering (rated load)
Measures and weights
Weight
57.0
127.0
163.0
3 .0
1 6
.5
0
17
63.5
81.5
4.0
Output
Output rated voltage
Output voltage range
Resistance to reverse feed max.
Output rated current
Power Boost
Top Boost
Overload behaviour
Parallel connection
max. Power loss idling/nominal load
Efficiency
Correction time
Output limited current
Leakage current (50 Hz)
Signaling
Status indicator
Environment
Ambient temperature
Storage temperature
Derating
Required minimum spacing (left/right)
Type of cooling
Required minimum spacing (over/under)
Safety and protection
Protection index
Safety class (prepared)
Accessory
Connector for signalling
Order numbers
Order Number
Subject to change.