Electrical Specifications
Input Voltage Range:
Frequency:
Power Factor:
Inrush Current:
Input Current:
Maximum Power:
Line Regulation:
Load Regulation:
Typical Efficiency
Protection:
100 - 277 Nom. Vac (90 - 305 V Min/Max)
50/60 Hz Nom. (47-63 Hz Min/Max)
>0.90 @ full load, 100V through 277V
60 A @ 230Vac
0.70 A @ 100 Vac, 0.35 A @ 220 Vac
50W
± 2%
± 5%
83-89% typical @ maximum load
Over-Voltage, Output Over-Current, Over-Temperature,
Output Short Circuit Protection with Auto Recovery
Environmental Specifications
Minimum Starting Temp:
Maximum Case Temp.
Storage Temperature:
Humidity:
Cooling:
Sound Rating:
MTBF:
Lifetime:
-35ºC
90°C
-40ºC to +85ºC
10% to 100%
Convection
Class A
487,000 Hours @ 25ºC, 80% load, 110VAC input on
4200 mA output model
66,000 Hours @ 45ºC, 80% load, 110VAC input on
4200 mA output model
Model Number
• Total Power: 50 Watts
• Input Voltage: 100-277 Vac Nom.
• UL Dry & Damp Location Rated
• IP67
• High Efficiency, High Power Factor
• Input/Output Protection & Lightning Protection
• UL8750 and EN61347 Certified
Output Current
(mA)
350
450
700
1100
1400
1750
2100
2800
3330
4200
Output Voltage
Range
(Vdc)
47-142
36-110
24-72
16-48
12-36
9-29
8-24
6-18
5-15
4-12
Class 2:
Max. Output
Power
(W)
50
50
50
50
50
50
50
50
50
50
US/Canada
Typical
Efficiency
91%
91%
91%
90%
90%
90%
87%
89%
88%
87%
US Only
TRC-050S035DT
TRC-050S045DT
TRC-050S070DT
TRC-050S110DT
TRC-050S140DT
TRC-050S175DT
TRC-050S210DT
TRC-050S280DT
TRC-050S333DT
TRC-050S420DT
E332160
Note:
LED drivers are designed and intended to operate LED loads only.
Non-LED loading may be outside the specified design limits of our
LED drivers, and therefore cannot be covered by any warranty.
If you desire to use our LED drivers to operate non-LED loads
please contact us to discuss compatibility.
Specifications subject to change without notice.
Rev 9-1-15
Thomas Research Products • 1225 Bowes Rd • Elgin, IL 60123 • T 847-515-3057 • F 847-515-3047 • www.trpssl.com

TRC-050S110DT Related Products

TRC-050S110DT TRC-050S140DT TRC-050S035DT TRC-050S045DT TRC-050S333DT TRC-050S175DT TRC-050S070DT TRC-050S210DT TRC-050S280DT TRC-050S420DT
Description Switch Mode LED Drivers - Constant Current Switch Mode LED Drivers - Constant Current Switch Mode LED Drivers - Constant Current Switch Mode LED Drivers - Constant Current Switch Mode LED Drivers - Constant Current Switch Mode LED Drivers - Constant Current Switch Mode LED Drivers - Constant Current Switch Mode LED Drivers - Constant Current Switch Mode LED Drivers - Constant Current Switch Mode LED Drivers - Constant Current
Zigbee control electric fan
I now have a ZigBee board and a DC fan (DC motor). How do I build the hardware circuit? What else do I need? How does the ZigBee control signal control the speed of the DC motor? Can I add an msp430 b...
潇雨如烟6 RF/Wirelessly
About the equivalent series resistance problem
For a 700mH large coil (similar to the coil of a contactor), the Rs is 270Ω when tested with a benchtop LCR bridge, but only 77Ω when tested directly with a multimeter resistance range. Therefore, how...
呜呼哀哉 Analog electronics
【Keysight Essay Call】Keysight & HP customers all over the world
My article is published in word format, in the attachment. [b][color=#5E7384]This content is originally created by EEWORLD forum netizen [size=3]Daqin Zhengsheng[/size]. If you want to reprint or use ...
大秦正声 Test/Measurement
stm32 controls LCD1602 display, but the screen always displays two blank spaces, and the letter p is displayed as the letter r. Can you guys see what the problem is?
Guys, my LCD 1602 display always starts with two spaces, and the letter P is displayed as the letter R. What is the reason? Please help me....
ybxdn stm32/stm8
Ultra-High Resolution ADC with PGA for Seismic Monitoring and Energy Development
[b] Ultra-High Resolution Sigma-Delta ADC with PGA for Seismic Monitoring and Energy Development Data. The ADS1282 is an extremely high performance, single-chip analog-to-digital converter (ADC) with ...
refiner168 TI Technology Forum
How to Use an Operational Amplifier
pdf format Chapter 1 Operational Amplifiers Chapter 2 Basic Circuits Chapter 3 Oscillators Chapter 4 Audio Circuits Chapter 5 Filters Chapter 6 Other Circuits Chapter 7 Commonly Used Operational Ampli...
cqzy6666 MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2314  2701  271  1868  2577  47  55  6  38  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号