LDC-80-2100x

Description
90W Output Power
File Size1MB,4 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet Compare View All

LDC-80-2100x Overview

90W Output Power

LDC-80
Series
Compact, LED, 90W
Constant Current
AC/DC Power Supply
Key Features:
90W Output Power
UL 8750 Approved
Constant Current Output
Active PFC
90 - 305 VAC Input
IP65 / IP67 Rated
Meets EN 55015, EN 61547
Dimming Function
>50 kHour Life Expectancy
Lightning Surge Protection
Over Volt/Temp Protection
Power Factor Correction
Total Harmonic Distortion (THD)
Turn On Delay, See Note 3
Leakage Current
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Inrush Current, See Note 1
Input Current
Conditions
Min.
90
127
47
230 VAC
115 VAC
230 VAC
264 VAC
0.98 @ 115 VAC
0.96 @ 230 VAC
0.94 @ 264 VAC
See Note 2
115 VAC
230 VAC
277 VAC
Conditions
V
IN
= Min to Max
See Note 4
115 VAC 16.0
±10%, Autorecovery
Continuous
Autorecovery
95
Conditions
Min.
Input to Output 3,750
Input to FG 2,000
Output to FG
500
Input to Output
Input to FG 100 M
Output to FG
Min.
Typ.
Max.
305
431
63
Units
VAC
VDC
Hz
A Pk
A
75
1.10
0.55
0.50
20
1.0
0.5
0.75
Typ.
±5.0
±1.0
1.0
±5.0
85
107
Typ.
Max.
Max.
%
S
mA
Units
%
%
V
P-P
%
mS
°C
%
IOUT
Units
VAC
Output
Parameter
Output Current Accuracy
Line Regulation
Ripple & Noise (20 MHz)
Output Ripple Current
Hold-Up Time
Over Temperature Protection
Short Circuit Protection, See Note 5
Overload Protection
General
Parameter
Isolation Voltage, 60S
Insulation Resistance
EMI Characteristics
Parameter
EMI
EMS
Surge
/ 500 VDC / 25°C / 70% RH
Standard
EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743
EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1
10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50
µS
Min.
Typ.
Max.
-40
+25
+70
-40
+85
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing
95
Ambient
Conditions
Units
°C
°C
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Weight
See Mechanical Diagrams (Page 4)
32.1 Oz (950g)
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
220
kHours
See Note 6
50
kHours
UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14
5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis
Reliability Specifications
Parameter
MTBF
Life Expectancy
Safety Standards
Vibration
www.micropowerdirect.com

LDC-80-2100x Related Products

LDC-80-2100x LDC-80-1750x LDC-80-0350x LDC-80-0700x LDC-80-1400x LDC-80 LDC-80-2450x
Description 90W Output Power 90W Output Power 90W Output Power 90W Output Power 90W Output Power 90W Output Power 90W Output Power

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2619  329  2643  794  1610  53  7  54  16  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号