PS14-1112Q

Description
Pushbutton Switch
CategoryMechanical and electronic products    switch   
File Size731KB,10 Pages
ManufacturerElectroswitch
Download Datasheet Parametric View All

PS14-1112Q Overview

Pushbutton Switch

PS14-1112Q Parametric

Parameter NameAttribute value
MakerElectroswitch
Reach Compliance Codeunknow
ECCN codeEAR99
Manufacturer's serial numberPS
Switch typePUSHBUTTON SWITCH
MINIATURE SWITCHES
Sensitive Snap-Action Pushbutton Switches —
Solder and P.C. Terminals (Momentary Action)
SERIES
PS
5 AMP. (S.P.)
1 AMP (D.P.)
0.4 VA
DIRECT PANEL MOUNT
ONE POLE
TWO POLE
Basic P/N
PS
Terminal Type
1 - Solder lug
2 - Printed Circuit
Terminals
Poles
1 - One
2 - Two
0-
1-
2-
3-
4-
5-
Cap Size
No Cap
.200 Dia.
.375 Dia.
.450 Sq.
.310 Dia.
.780 Sq.
Cap Color
0-
1-
2-
3-
No Cap
Black
White
Ted
Contact Material-Type
B - Gold/Nickel/Brass
G - Gold/Nickel/
Silver
Q - Coin Silver
Small Cap
.200
Description
P/N
W-KN-16
W-KN-16A
W-KN-16B
W-KN-32
W-KN-32A
W-KN-32B
W-KN-17
W-KN-17A
W-KN-17B
W-KN-18
W-KN-18A
W-KN-18B
W-KN-52
W-KN-52A
W-KN-52B
Bezel
W-BZ-21
Color
Black
White
Red
Black
White
Red
Black
White
Red
Black
White
Red
Black
White
Red
Black
Single pole circuit rated 5 amps, double pole circuit rated 1 amp.
Ratings are 0.4 VA — 28 BAC or DC
Supplied with .90” square black bezel as Standard
Medium Cap
.310
EXAMPLES:
PS1-100Q = One-pole, S.L., 5 amp., No Cap,
Coin Silver Contacts
PS2-221B = Two-pole, PC, .4 VA, .375 Dia., Black Cap.,
Gold/Nickel/Brass Contacts
NEW .780” SQUARE
CAP AND BEZEL
Large Cap
.375
Square Cap
.450
W-NU-29A
W-NU-30A
DECORATIVE FACE NUTS
(SEE NOTE UNDER MATERIALS)
.780 Square
Cap
.90 Square
Bezel
SPECIFICATIONS
Contact Rating
– Letter codes G and Q (1 Pole) 5
amp resistive @ 125 VAC (
U.L. recognized, CSA
certified
) or 5 amp resistive @ 28 VDC. (2 pole) 1
amp resistive @ 125 VAC (
U.L. recognized, CSA
certified
) or 1 amp resistive @ 28 VDC.
Letter codes B and G – (1 and 2 Poles) 0.4
Volt-amps (VA) maximum @ 28 V max. (AC or
DC).
Contact Resistance
– 50 milliohms maximum.
Insulation Resistance
– 1,000 megohms min-
imum.
Dielectric Strength
– 1,000 volts RMS minimum
at sea level.
Electrical Life
– 60,000 cycles minimum at full
load-resistive.
Maximum Allowable Installation Force on
Plunger
– 10 pounds.
Multi-pole contacts do not make and break
simultaneously.
MATERIALS
Case
— Diallyl Phthalate.
Bushing
— Brass, nickel plated.
Housing
— Stainless steel.
Plunger
— Thermoplastic.
Common Contact
— Refer to contact material
table above.
Center & End Contact
— Refer to contact
material table above.
Hardware
— (2) Hex nuts W-NU-11, brass nickel
plated. (1) Internal tooth lockwasher W-WA-16,
steel chromium plated. (1) Locking Ring W-RI-16,
C.R.S. nickel plated.
Decorative Face Nuts
— Brass, bright chrome
plated. See Page 16 for complete dimensions.
Solder Lug Terminal
Printed Circuit Terminal
4
Litho in U.S.A GG
Router Installation
Router Installation Technology...
Smithlee89 RF/Wirelessly
Waveform diagram problem of volt-second law
[Ask if you don't understand] The figure is a waveform diagram about the volt-second product law, from "Mastering Switching Power Supply Design" (Second Edition). Von represents the inductor voltage w...
shaorc Power technology
About Wi-Fi Development
The development board is Ingenic, with Samsung 2440 processor, Atheros 6002 Wi-Fi module, Wince 5.0 system. After the driver of the Wi-Fi module is transplanted, it can connect to the AP well without ...
jim200503 Embedded System
Can't the member function setbkcolor of the EVC treectrl control be used? (I don't have many points left, thank you for your help)
I wonder if you have encountered this problem when compiling interface programs under EVC. It is strange that there is no m_tree.SetBkColor(); when compiling, it says that it is not a member function ...
damy Embedded System
[Audio recognizer based on GD32F350RB] 3. CMSIS-NN neural network configuration analysis
[i=s]This post was last edited by Beifang on 2018-9-21 10:14[/i] 1. After completing the basic test, you can analyze the program and logic of this specific implementation in detail. As shown in the fo...
北方 GD32 MCU
What is the difference between industrial PLC program control and Java?
May I ask what are the differences and connections between industrial PLC program control and Java? Can the two replace each other?...
webnoise Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2877  2103  1083  1976  1942  58  43  22  40  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号