The Ortel PONA 2100 Series Erbium Doped Fiber Amplifier (EDFA)
is an ideal building block for OEM system integrators. The family of
PONA 2100 series EDFAs is designed to meet the most demanding
noise performance requirements of CATV applications, and
performs all the functions required of an optical amplifier for system
integration. PONA 2100 series EDFAs provide optical isolation on
the input and output of the gain block for stable, low noise operation.
The input and output optical signal power levels are detected for
monitoring and control. The input optical signal is amplified with
active gain control for a constant output power level, or with active
output power control for constant gain mode.
The PONA 2100
series EDFAs also provide monitors and associated alarms for all
vital characteristics. The optical output of the PONA 2100 series
EDFAs can be split into multiple ports by an optional external
splitter.
For more information on this and other products:
Contact Sales at Ortel 626-293-3400, or visit www.ortel.com.
PONA 2100 Series EDFA
Rev B
DATA SHEET
|
FEBRUARY 2006
Optical / Electrical Characteristics
PROPERTY
Product Code
PERFORMANCE
Operating Input Power
Operating Input Power
Output Power
Noise Figure
(Note 2)
Pin
(dBm)
Pin
(dBm)
Po(dBm)
NF (dB)
NF (dB)
NF (dB)
Static Gain Flatness
Dynamic Gain Flatness
(Note 4)
GF (dB)
(dB)
(dB)
(dB)
Output Power Stability
Power Consumption
(steady state regime)
Notes
:
1.
2.
3.
4.
5.
(dB)
Psys(W)
Typ/Max
Typ/Max
Typ/Max
Max
Max
Max
Max
Max
Max
Max
Min
12
-10
14
+/-.25
4.5/5.0
4.0/4.5
4.0/4.5
+/-0.5
+/-1.0
+/-0.5
+/-0.5
+/- 0.1
5
12
-10
17
+/- .25
4.5/5.0
4.0/4.5
4.0/4.5
+/-0.5
+/-1.25
+/-0.5
+/-0.5
+/- 0.1
7
12
-10
20
+/- .25
4.5/5.0
4.0/4.5
4.0/4.5
+/-0.5
+/-1.5
+/-1.0
+/-1.0
+/- 0.1
9
12
-10
22
+/- .25
4.5/5.0
4.0/4.5
4.0/4.5
+/-0.5
+/-2.0
+/-1.0
+/-1.0
+/- 0.1
12
12
-10
24
+/- .25
5.0/5.5
4.5/5.0
4.5/5.0
+/-0.5
+/-2.0
+/-1.0
+/-1.0
+/- 0.1
20
12
-10
26
+/- .25
5.0/5.5
4.5/5.0
N/A
+/-0.5
+/-2.0
N/A
N/A
+/- 0.1
27
12
-10
27
+/- .25
5.0/5.5
4.5/5.0
N/A
+/-0.5
+/-2.0
N/A
N/A
+/- 0.1
32
Nominal
-00 and -01 versions
-02 version
-03 version
(Note 3)
-00 and -02 versions
-01 version
-03 version
(Note 5)
50 C Case
o
UNIT
LIMIT
2114
2117
PONA MODELS
2120
2122
2124
2126
2127
COMMENTS
(note 1)
Unless stated otherwise all specifications apply over the full temperature range and humidity
Measured with 8 evenly spread signals @ 25°C,
Σ
Pin = 0 dBm.
Measured with a swept Probe Signal (Pp), where Pp = 0 dBm @ 25°C
Measured with a swept Probe Signal (Pp), and a fixed Tone Signal (Pt) @ 1545 nm; (Pt = Pp+20 dB; Pt + Pp = 0 dBm) @ 25°C; Gain
Flattened Option with
∆G
= +/-0.5dB is available for some Models
Stability over polarization and temperature
General and Mechanical Specifications
PROPERTY
GENERAL
Operating Wavelength
Operating Case Temperature
Storage Temperature
Operating Humidity
Voltage Supply Range
Optical Connectors
Dimensions In Inches
REQUIREMENT
1530 ~ 1562nm
0°C to 50°C
-40°C to 85°C
20% to 85%
85 VAC to 265 VAC 50/60 Hz
-36 to –60 V DC
SC/APC; SC/UPC; FC/APC;
FC/UPC; E2000/APC
19.0”W x 14.76”D x 1.72”H
Non-condensing
Standard
Optional
User Specified
19’’ Rack Mounted, 1U
Standard
COMMENTS
Ortel, a division of EMCORE
2 of 4
PONA 2100 Series EDFA
Rev B
DATA SHEET
|
FEBRUARY 2006
Outline Drawing
AC and DC versions shown below with 8-port option
DC Version
AC Version
Ortel, a division of EMCORE
3 of 4
PONA 2100 Series EDFA
Rev B
DATA SHEET
|
FEBRUARY 2006
Compliance Information
89/336/EEC Electromagnetic Compatibility Directive, amended by 92/31/EEC & 93/68/EEC
73/23/EEC Low Voltage Directive, amended by 93/68/EEC
EN 50083-2, (2001)
Cable networks for TV signals, sounds and interactive services, Part 2 Electromagnetic
Compatibility for equipment.
EN 55013
EN 61000-3-2
EN 55020
EN 61000-4-6
EN 61000-4-3
EN 61000-4-2
EN 61000-4-4
EN 60950
EN 60825-1
EN 60825-2
CDRH
Mains Conducted Emissions
Mains Frequency and its Harmonics, Conducted Emissions
Radiation from Active Equipment, Radiated Immunity
Immunity of Active Equipment, Radiated Immunity
Immunity of Active Equipment, Radiated Immunity
Electrostatic Discharge Immunity
Electrical Fast Transient / Burst Immunity
Low Voltage Directives
Laser Safety Requirement
Laser Safety Requirement
Laser Safety Requirement
Ordering Information
PONA21
-
-
-
-
Optical
Output
Power
14
- 14 dBm
17
- 17 dBm
20
- 20 dBm
22
- 22 dBm
24
- 24 dBm
26
- 26 dBm
27
- 27 dBm
Output
Ports
1
2
4
8
Input Voltage
AC
– 90-260V 50/60 Hz
DC
– - 48 V
SC
FC
EC
TC
GC
Connector
-
-
-
-
-
SC/APC
FC/APC
E2000/APC
SC/UPC
FC/UPC
GFF/ NF options
00 - Standard
01 - Standard with Gain Flattened option
02 - Standard with Low NF option
03 - Low NF and Gain Flattened
Note: The maximum number of output ports when using E2000 connectors is four. All other optical connectors allow for
the eight ports option
Example:
PONA2120-2-AC-SC-00:
Standard 20 dBm EDFA with AC Power Supply, two (2) optical outputs, and SC/APC optical connectors
Information contained herein is deemed to be reliable and accurate as of issue date. EMCORE reserves the right to change the design or specifications of
the product at any time without notice. Ortel, the Ortel logo, EMCORE, and the EMCORE logo are trademarks of EMCORE Corporation.
[color=#000][backcolor=rgb(232, 232, 232)][size=15px]407 serial port 1 uses DMA to send and receive data. Everything is normal for sending, but there is a problem with receiving. The receiving uses th...
[size=5] As shown in the figure, there are many arrays with different lengths. They all need to be sent to the corresponding modules through the serial port. However, it is too troublesome to write a ...
PTT is also known as "push to talk". Its characteristics are short call establishment time, occupying the channel only when speaking, and only monitoring the channel when answering. The receiver does ...
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
Analog engineers have traditionally struggled with complexity when designing power supplies that required multiple outputs, dynamic load sharing, hot-swap, or extensive fault-handling capabilities....[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
The reason for the light decay of white LEDs: the decline of phosphor performance
So far, the rapid decline of the luminous performance of white light LEDs, especially low-power white light LE...[Details]
introduction
The emergence of high-performance, low-power embedded CPUs and high-reliability network operating systems has made it possible to implement applications with large amounts of comp...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
1 Introduction
Water resources are the basic conditions for human survival and the lifeline of economic development. The reality shows that due to the global shortage of water resources and th...[Details]
This week, Microsoft held its 2012 Microsoft Worldwide Partner Conference (WPC) in Toronto, Canada. At the conference, Microsoft showed its new products and services to partners around the world. A...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]