EEWORLDEEWORLDEEWORLD

Part Number

Search

UM4-GF2318-49.900

Description
Parallel - 3Rd Overtone Quartz Crystal, 49.9MHz Nom,
CategoryPassive components    Crystal/resonator   
File Size60KB,2 Pages
ManufacturerILSI
Websitehttp://www.ilsiamerica.com
Environmental Compliance  
Download Datasheet Parametric View All

UM4-GF2318-49.900 Overview

Parallel - 3Rd Overtone Quartz Crystal, 49.9MHz Nom,

UM4-GF2318-49.900 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerILSI
Reach Compliance Codecompli
Other featuresAT CUT
Ageing5 PPM/YEAR
Crystal/Resonator TypePARALLEL - 3RD OVERTONE
Drive level1000 µW
frequency stability0.003%
frequency tolerance25 ppm
load capacitance18 pF
Installation featuresTHROUGH HOLE MOUNT
Nominal operating frequency49.9 MHz
Maximum operating temperature60 °C
Minimum operating temperature-10 °C
physical sizeL8.0XB3.2XH4.7 (mm)/L0.315XB0.126XH0.185 (inch)
Series resistance70 Ω
surface mountNO
Terminal surfaceTin/Silver/Copper - with Nickel barrie
2 Lead Metal Package, 3.2 mm x 8 mm
Product Features:
Low Cost
RoHs Compliant
Compatible with Leadfree Processing
UM1 / UM4 / UM5 Series
Applications:
Fibre Channel
Server & Storage
Sonet /SDH
802.11 / Wifi
T1/E1, T3/E3
System Clock
Frequency
7 MHz to 160.000 MHz
ESR (Equivalent Series Resistance)
7.0 MHz – 9.9 MHz
10.0 MHz – 14.9 MHz
15 MHz – 29.9 MHz
30 MHz – 36 MHz
rd
30 MHz – 49.9 MHz (3 O.T.)
rd
50 MHz – 100 MHz (3 O.T.)
th
75 MHz – 160 MHz (5 O.T.)
100
60
30
20
70
50
100
Max.
Max.
Max.
Max.
Max.
Max.
Max.
Shunt Capacitance (C0)
Frequency Tolerance @ 25
C
Frequency Stability over
Temperature
Crystal Cut
Load Capacitance
Drive Level
Aging
Temperature
Operating
Storage
7 pF Max.
30 ppm Standard (see Part Number Guide for more options)
50 ppm Standard (see Part Number Guide for more options)
AT Cut Standard
18 pF Standard (see Part Number Guide for more options)
1 mW Max.
5 ppm Max. / Year Standard
0 C to +70 C Standard (see Part Number Guide for more options)
-40 C to +85 C Standard
Part Number Guide
Package
Stability
(ppm) at Room
Temperature
B = ±50 ppm
F = ±30 ppm
G = ±25 ppm
H = ±20 ppm
I = ±15 ppm
J = ±10 ppm*
Sample Part Number:
Stability
(ppm) over Operating
Temperature
B = ±50 ppm
F = ±30 ppm
G = ±25 ppm
H = ±20 ppm
I = ±15 ppm**
J = ±10 ppm**
UM1 - FB1F18 - 20.000
Operating
Temperature Range
0 = 0°C to +50°C
1 = 0°C to +70°C
2 = -10°C to +60°C
3 = -20°C to +70°C
5 = -40°C to +85°C
9 = -10°C to +50°C
Mode
(overtone)
F = Fundamental
3 = 3
rd
overtone
5 = 5
th
overtone
Load Capacitance
(pF)
Frequency
UM1 -
(8.0 mm H)
UM4 -
(4.7 mm H)
18 pF Standard
Or Specify
- 20.000 MHz
UM5 -
(6.0 mm H)
* Not available at all frequencies. ** Not available for all temperature ranges.
e-mail@ilsiamerica.com
www.ilsiamerica.com
ILSI
America
Phone: 775-851-8880 • Fax: 775-851-8882• e-mail: e-mail@ilsiamerica.com • www.ilsiamerica.com
06/09
Specifications subject to change without notice
Page 1
PIC chip selection
I want to choose a PIC chip. The requirements are that it has AD and DA, the number of pins is less than 20, the reference voltage range is relatively large, preferably between 1.8 and 5.5V, the power...
xzfx Microchip MCU
Help: Please help with a grammatical error
The following program unsigned char search_1(unsigned char num_0) has a syntax error. When running, it prompts an error "syntax error near 'unsigned'". I really can't figure out what it is. Please hel...
dhuazhang Embedded System
How to effectively transfer data from the application to the stream driver?
2410 + CE5.0 + SPI stream driver Now, the application needs to frequently transfer 100KB byte arrays to the stream driver; I would like to seek an effective method from all the experts, please give me...
Alen.yang Embedded System
What is the best solution for transmitting images over long distances (20 km)? ? Not using the mobile operator's network.
Hello everyone!! I recently received a project for long-distance image transmission; it mainly takes some images and transmits them back to the ground after compression. The distance is about 20 kilom...
qinsong RF/Wirelessly
Fluke-279FC+ Field Application
[i=s]This post was last edited by fyaocn on 2016-9-23 12:23[/i] 1. Overview The original plan was to conduct field verification of the specific solutions proposed for the actual problems. Therefore, t...
fyaocn Test/Measurement
How to Start DSP Applications Using DSP/BIOS II
How to use DSP/BIOS II to start DSP applications...
灞波儿奔 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1131  1656  1333  25  1920  23  34  27  1  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号