MIL–PRF (CWR Style) Established Reliability – T409 Series CWR09 Style MIL–PRF–55365/4
Table 1 – Ratings & Part Number Reference
Rated
Voltage
V
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25
25
V
Rated
Cap
µF
2.2
4.7
6.8
10
15
33
68
100
1.5
3.3
4.7
6.8
10
22
47
68
1
2.2
3.3
4.7
6.8
15
33
47
0.68
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
6.8
15
22
0.33
0.68
1
1.5
2.2
4.7
6.8
µF
Case Code/
Case Size
KEMET/EIA
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T409A225(1)004(2)(3)(4)
T409B475(1)004(2)(3)(4)
T409C685(1)004(2)(3)(4)
T409D106(1)004(2)(3)(4)
T409E156(1)004(2)(3)(4)
T409F336(1)004(2)(3)(4)
T409G686(1)004(2)(3)(4)
T409H107(1)004(2)(3)(4)
T409A155(1)006(2)(3)(4)
T409B335(1)006(2)(3)(4)
T409C475(1)006(2)(3)(4)
T409D685(1)006(2)(3)(4)
T409E106(1)006(2)(3)(4)
T409F226(1)006(2)(3)(4)
T409G476(1)006(2)(3)(4)
T409H686(1)006(2)(3)(4)
T409A105(1)010(2)(3)(4)
T409B225(1)010(2)(3)(4)
T409C335(1)010(2)(3)(4)
T409D475(1)010(2)(3)(4)
T409E685(1)010(2)(3)(4)
T409F156(1)010(2)(3)(4)
T409G336(1)010(2)(3)(4)
T409H476(1)010(2)(3)(4)
T409A684(1)015(2)(3)(4)
T409B155(1)015(2)(3)(4)
T409C225(1)015(2)(3)(4)
T409D335(1)015(2)(3)(4)
T409E475(1)015(2)(3)(4)
T409F106(1)015(2)(3)(4)
T409G226(1)015(2)(3)(4)
T409H336(1)015(2)(3)(4)
T409A474(1)020(2)(3)(4)
T409B684(1)020(2)(3)(4)
T409B105(1)020(2)(3)(4)
T409C155(1)020(2)(3)(4)
T409D225(1)020(2)(3)(4)
T409E335(1)020(2)(3)(4)
T409F685(1)020(2)(3)(4)
T409G156(1)020(2)(3)(4)
T409H226(1)020(2)(3)(4)
T409A334(1)025(2)(3)(4)
T409B684(1)025(2)(3)(4)
T409C105(1)025(2)(3)(4)
T409D155(1)025(2)(3)(4)
T409E225(1)025(2)(3)(4)
T409F475(1)025(2)(3)(4)
T409G685(1)025(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/4
Part Number
(See below for
part options)
CWR09C(3)225(1)(2)(5)
CWR09C(3)475(1)(2)(5)
CWR09C(3)685(1)(2)(5)
CWR09C(3)106(1)(2)(5)
CWR09C(3)156(1)(2)(5)
CWR09C(3)336(1)(2)(5)
CWR09C(3)686(1)(2)(5)
CWR09C(3)107(1)(2)(5)
CWR09D(3)155(1)(2)(5)
CWR09D(3)335(1)(2)(5)
CWR09D(3)475(1)(2)(5)
CWR09D(3)685(1)(2)(5)
CWR09D(3)106(1)(2)(5)
CWR09D(3)226(1)(2)(5)
CWR09D(3)476(1)(2)(5)
CWR09D(3)686(1)(2)(5)
CWR09F(3)105(1)(2)(5)
CWR09F(3)225(1)(2)(5)
CWR09F(3)335(1)(2)(5)
CWR09F(3)475(1)(2)(5)
CWR09F(3)685(1)(2)(5)
CWR09F(3)156(1)(2)(5)
CWR09F(3)336(1)(2)(5)
CWR09F(3)476(1)(2)(5)
CWR09H(3)684(1)(2)(5)
CWR09H(3)155(1)(2)(5)
CWR09H(3)225(1)(2)(5)
CWR09H(3)335(1)(2)(5)
CWR09H(3)475(1)(2)(5)
CWR09H(3)106(1)(2)(5)
CWR09H(3)226(1)(2)(5)
CWR09H(3)336(1)(2)(5)
CWR09J(3)474(1)(2)(5)
CWR09J(3)684(1)(2)(5)
CWR09J(3)105(1)(2)(5)
CWR09J(3)155(1)(2)(5)
CWR09J(3)225(1)(2)(5)
CWR09J(3)335(1)(2)(5)
CWR09J(3)685(1)(2)(5)
CWR09J(3)156(1)(2)(5)
CWR09J(3)226(1)(2)(5)
CWR09K(3)334(1)(2)(5)
CWR09K(3)684(1)(2)(5)
CWR09K(3)105(1)(2)(5)
CWR09K(3)155(1)(2)(5)
CWR09K(3)225(1)(2)(5)
CWR09K(3)475(1)(2)(5)
CWR09K(3)685(1)(2)(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Maximum/5
Minutes
1
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
5.0
1.0
1.0
1.0
1.0
1.0
2.0
4.0
5.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
µA @ +20ºC
Maximum/5
Minutes
DF
% @ +20ºC
120 Hz
Maximum
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
% @ +20ºC
120 Hz
Maximum
ESR
Ω @ +20ºC
100 kHz
Maximum
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
5.5
4.5
3.5
2.2
1.1
0.9
10.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
10.0
12.0
6.0
5.0
4.0
2.4
1.1
0.9
15.0
7.5
6.5
6.5
3.5
2.5
1.2
Ω @ +20ºC
100 kHz
Maximum
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
MIL-PRF-55365/4
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates termination finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, or C = -55°C +85°C before Weibull. Designates surge current
option. Refer to Ordering Information for additional detail.
There are many types of capacitors. In order to distinguish them, several Latin letters are often used to represent the types of capacitors, as shown in Figure 1. The first letter C represents the cap...
[img]http://pic.yupoo.com/pole625/81380599a8bf/ia6exy6r.jpg[/img] This is the waveform under the simulator, using the standard SDK for WinCE5.0. But when the program is loaded on wince, it becomes a d...
Development Board IntroductionBased on TI AM5728 floating point dual DSP C66x + dual ARM Cortex-A15 industrial control and high-performance audio and video processor;
Multi-core heterogeneous CPU, int...
[align=left]The 2019 National College Student Electronic Design Competition has kicked off. The competition topics include "theoretical design" and "actual production", based on the design and applica...
With the promotion of the construction of intelligent communities in the country, anti-theft systems have become essential equipment for intelligent communities. Especially in recent years, the urg...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
Vertical cavity surface emitting lasers (VCSELs) are gradually replacing traditional edge emitting lasers, especially in low bandwidth and short-distance communication systems where cost factors ar...[Details]
The automotive lighting and signal control system is responsible for controlling the vehicle's lighting, signal lights, electric horns, reversing and brake buzzers. Traditional automotive lighting...[Details]
The typical fault troubleshooting listed below is for reference of maintenance personnel.
When the computer is turned on, the indicator light is off and there is no screen display
Mainte...[Details]
Capacitors
are basic components in various electronic devices and are widely used for bypassing, coupling,
filtering
, tuning, etc. in electronic circuits. However, to use capacitors,...[Details]
We know that the inverter consists of two parts: the main circuit and the control circuit. Due to the nonlinearity of the main circuit (switching action), the inverter itself is a source of harmoni...[Details]
With concerns about the growing energy crisis, motor efficiency has become an important and timely topic. This is because motors use 63% to 70% of the electricity produced in the United States and ...[Details]
Traditional
virtual instruments
consist of a data acquisition
board
based on PCI bus and
corresponding software. However, with
the rapid development of
computer
network techno...[Details]
0 Introduction
In order to improve the automation control of shortwave transmitters, so that they can automatically process from far to near, the technicians here use the ICS system to complete the ...[Details]
This article discusses the six design steps of LED lighting system design in detail: (1) determine the lighting requirements; (2) determine the design goals and estimate the optics; (3) the efficie...[Details]
Introduction
my country's rapid economic growth is mainly due to the development of manufacturing and the acceleration of urbanization. However, urbanization cannot be achieved at the expense ...[Details]
0 Introduction
With the rapid development of modern power electronics technology, various power electronic devices have been widely used in various fields such as power systems, industry, an...[Details]
Applying fieldbus technology on new beer production lines is the first choice for large beer companies with strong management level and technical strength. Guangzhou Zhujiang Beer Group Co., Ltd. i...[Details]
New Automobile
Hydraulic Clutch
The hydraulic control system uses almost 100% advanced engineering plastics, which overcomes the shortcomings of the main and branch cylinders of metal clutc...[Details]