MIL–PRF (CWR Style) Established Reliability – T429 Series CWR29 Style MIL–PRF–55365/11
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
VDC
Rated
Cap
µF
2.2
3.3
4.7
4.7
6.8
6.8
10
10
15
15
22
22
33
33
33
47
68
68
100
100
150
220
330
1.5
3.3
3.3
4.7
4.7
6.8
6.8
10
10
15
15
15
22
22
22
33
47
47
68
68
68
100
150
220
330
1
µF
Case Code/
Case Size
KEMET/EIA
A/1005
A/1005
A/1005
B/1505
A/1005
C/2005
B/1505
D/1510
B/1505
E/2010
B/1505
D/1510
D/1510
E/2010
F/2214
E/2010
E/2010
G/2711
F/2214
H/2915
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
A/1005
C/2005
B/1505
D/1510
B/1505
E/2010
B/1505
D/1510
E/2010
D/1510
E/2010
F/2214
E/2010
F/2214
G/2711
F/2214
G/2711
H/2915
G/2711
G/2711
H/2915
H/2915
A/1005
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T429A225(1)004(2)(3)(4)
T429A335(1)004(2)(3)(4)
T429A475(1)004(2)(3)(4)
T429B475(1)004(2)(3)(4)
T429A685(1)004(2)(3)(4)
T429C685(1)004(2)(3)(4)
T429B106(1)004(2)(3)(4)
T429D106(1)004(2)(3)(4)
T429B156(1)004(2)(3)(4)
T429E156(1)004(2)(3)(4)
T429B226(1)004(2)(3)(4)
T429D226(1)004(2)(3)(4)
T429D336(1)004(2)(3)(4)
T429E336(1)004(2)(3)(4)
T429F336(1)004(2)(3)(4)
T429E476(1)004(2)(3)(4)
T429E686(1)004(2)(3)(4)
T429G686(1)004(2)(3)(4)
T429F107(1)004(2)(3)(4)
T429H107(1)004(2)(3)(4)
T429G157(1)004(2)(3)(4)
T429H227(1)004(2)(3)(4)
T429H337(1)004(2)(3)(4)
T429A155(1)006(2)(3)(4)
T429A335(1)006(2)(3)(4)
T429B335(1)006(2)(3)(4)
T429A475(1)006(2)(3)(4)
T429C475(1)006(2)(3)(4)
T429B685(1)006(2)(3)(4)
T429D685(1)006(2)(3)(4)
T429B106(1)006(2)(3)(4)
T429E106(1)006(2)(3)(4)
T429B156(1)006(2)(3)(4)
T429D156(1)006(2)(3)(4)
T429E156(1)006(2)(3)(4)
T429D226(1)006(2)(3)(4)
T429E226(1)006(2)(3)(4)
T429F226(1)006(2)(3)(4)
T429E336(1)006(2)(3)(4)
T429F476(1)006(2)(3)(4)
T429G476(1)006(2)(3)(4)
T429F686(1)006(2)(3)(4)
T429G686(1)006(2)(3)(4)
T429H686(1)006(2)(3)(4)
T429G107(1)006(2)(3)(4)
T429G157(1)006(2)(3)(4)
T429H227(1)006(2)(3)(4)
T429H337(1)006(2)(3)(4)
T429A105(1)010(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/11
Part Number
(See below for
part options)
CWR29C(3)225(1)(2)A(5)
CWR29C(3)335(1)(2)A(5)
CWR29C(3)475(1)(2)A(5)
CWR29C(3)475(1)(2)B(5)
CWR29C(3)685(1)(2)A(5)
CWR29C(3)685(1)(2)C(5)
CWR29C(3)106(1)(2)B(5)
CWR29C(3)106(1)(2)D(5)
CWR29C(3)156(1)(2)B(5)
CWR29C(3)156(1)(2)E(5)
CWR29C(3)226(1)(2)B(5)
CWR29C(3)226(1)(2)D(5)
CWR29C(3)336(1)(2)D(5)
CWR29C(3)336(1)(2)E(5)
CWR29C(3)336(1)(2)F(5)
CWR29C(3)476(1)(2)E(5)
CWR29C(3)686(1)(2)E(5)
CWR29C(3)686(1)(2)G(5)
CWR29C(3)107(1)(2)F(5)
CWR29C(3)107(1)(2)H(5)
CWR29C(3)157(1)(2)H(5)
CWR29C(3)227(1)(2)H(5)
CWR29C(3)337(1)(2)H(5)
CWR29D(3)155(1)(2)A(5)
CWR29D(3)335(1)(2)A(5)
CWR29D(3)335(1)(2)B(5)
CWR29D(3)475(1)(2)A(5)
CWR29D(3)475(1)(2)C(5)
CWR29D(3)685(1)(2)B(5)
CWR29D(3)685(1)(2)D(5)
CWR29D(3)106(1)(2)B(5)
CWR29D(3)106(1)(2)E(5)
CWR29D(3)156(1)(2)B(5)
CWR29D(3)156(1)(2)D(5)
CWR29D(3)156(1)(2)E(5)
CWR29D(3)226(1)(2)D(5)
CWR29D(3)226(1)(2)E(5)
CWR29D(3)226(1)(2)F(5)
CWR29D(3)336(1)(2)E(5)
CWR29D(3)476(1)(2)F(5)
CWR29D(3)476(1)(2)G(5)
CWR29D(3)686(1)(2)F(5)
CWR29D(3)686(1)(2)G(5)
CWR29D(3)686(1)(2)H(5)
CWR29D(3)107(1)(2)G(5)
CWR29D(3)157(1)(2)G(5)
CWR29D(3)227(1)(2)H(5)
CWR29D(3)337(1)(2)H(5)
CWR29F(3)105(1)(2)A(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Max/5 Min
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
2.0
3.0
3.0
4.0
4.0
6.0
8.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
3.0
3.0
4.0
4.0
4.0
6.0
10.0
10.0
20.0
1.0
µA @ +20ºC
Max/5 Min
DF
% @ +20ºC 120
Hz Max
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
8.0
6.0
8.0
8.0
6.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
% @ +20ºC 120
Hz Max
ESR
Ω @ +20ºC
100 kHz Max
4.0
6.0
6.0
3.2
6.0
2.2
3.2
1.3
3.2
1.0
3.2
1.3
1.3
0.9
0.6
0.9
0.9
0.275
0.55
0.18
0.25
0.20
0.18
4.0
6.0
3.2
6.0
2.2
3.2
1.5
3.2
1.0
3.2
1.7
0.9
1.7
1.0
0.6
1.0
1.0
0.275
0.4
0.25
0.18
0.275
0.275
0.18
0.18
5.0
Ω @ +20ºC
100 kHz Max
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated Cap
Case Code/
Case Size
KEMET Part Number
MIL-PRF-55365/11
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, C = -55°C +85°C before Weibull or Z = None. Designates Surge
current option.
Refer to Ordering Information for additional detail.
My IAR version is IAR Assembler for MSP430 5.30.1. It says that this version uses MSP-FET430UIF and does not require the installation of drivers. It comes with the internal folder.I can download progr...
ULP Wireless Quarterly takes a closer look at NORDIC products and their applications. For 20 years NORDIC has been focusing on ultra-low power wireless communications below 1 GHz and 2.4 GHz , making ...
Using a development board based on SIMCOM300, I use the HyperTerminal to operate the target board. Using COM3, whether or not the development board is connected with a serial cable, sending AT will re...
This is my dspic33f chip displayed on 12864. Now I want to set the value of the first line by pressing the key, that is, to add and subtract a four-digit number one by one by using the plus and minus ...
I would like to ask if anyone has used x9c103 before? Can you please give me some advice on how to measure the resistance value? Also, can the sliding end be reset to the initial value at once, or doe...
Many security video surveillance systems collect images inside elevators. However, when the elevator is running, the image has moire interference, and some are so serious that the image content cannot...
1. Several nouns
ABI:
The specifications that an executable file must follow in order to run in a specific execution environment;
Separately generated relocatabl...[Details]
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
The problem of dynamic sealing of equipment always exists with the operation of the equipment. Today, we have specially sorted out the various commonly used sealing forms, usage scope and character...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
Whether it is an electric car or an ordinary fuel car, for the vast majority of car buyers, the final cost of use is what they care about most. For fuel cars, how to save fuel is what drivers care ...[Details]
Is pure electric vehicles a false proposition for long-distance driving? At least from my personal perspective, based on current technological and infrastructure standards, I believe so. Below, I'l...[Details]
Topics: Bring Your Own Device (BYOD) trends; the impact of using employees' own mobile devices to control access to work facilities and equipment on information security; and ways to securely imple...[Details]
According to foreign media reports, secondary battery materials company POSCO Future M announced that it has successfully developed two experimental (prototype) positive electrode materials for the...[Details]
On August 22, Lantu Motors officially launched its Lanhai Intelligent Hybrid technology via an online livestream. This intelligent hybrid technology, which integrates a full-range 800V high-voltage...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
This paper proposes a temperature real-time transmission and display solution based on LED optical data transmission, with Jingwei Yager low-power FPGA HR (Yellow River) series as the main controll...[Details]
introduction
According to the China Fire Statistics Yearbook, electrical fires accounted for more than 30% of fire accidents in the past decade, and the trend is increasing year by year. They ...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
Compared to cloud databases, minicomputers are purpose-built for decentralized, rugged computing at the edge of the network. By moving applications, analytics, and processing services closer to the...[Details]
To improve the lateral active safety of intelligent connected vehicles, the identification and definition of unexpected functional safety scenarios for the EPS (Electronic Steering System) ...[Details]