2649LPA7/110301LI

Description
Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2649LPA7/110301LI Overview

Rocker Switch, On-off-on, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2649LPA7/110301LI Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator colorBEIGE
Actuator length0.394 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact functionON-OFF-ON
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Serial communication problem!
I would like to ask if I do not process the serial port receiving and sending in the interrupt, but do it in the main program. I know that if I want to determine whether the serial port has received a...
tianzongwu Microcontroller MCU
LM3 Development Notes_3. Interrupt Learning
For a "naked" system, the use of interrupts is unavoidable. The interrupt operation functions of the Stellaris peripheral driver library are encapsulated in the .c/h files and interrupt.c/h files of t...
liongt Microcontroller MCU
What do powerpc-wrs-vxworks-ar etc. in vxworks mean?
A makefile written for software installation under vxworks_powerpc contains the following sentences: "CCROOT=/net/compiler/gcc_mpt_1.02/bin RANLIB = $(CCROOT)/powerpc-wrs-vxworks-ranlib AR = $(CCROOT)...
qqqyyy10000 Real-time operating system RTOS
I have watched the whole video, it is very good, but I don't know how much it costs. The AUTO tune operation is very simple and intuitive, and the noise floor value...
I have watched the entire video, it is very good, but I don't know what the price is. The AUTO tune operation is very simple and intuitive, the noise floor value is very good, ACPR is very useful for ...
chenwenjun123 Test/Measurement
The programmer who can't afford to be hurt! Chongqing IT man becomes young again after switching to selling fruits
Source website: NetEase Recently, two photos taken in 2011 and 2013 suddenly became popular on the Internet. The former is a man wearing glasses, with dark skin, greasy face and ordinary appearance. T...
szjlj168 Talking
Duty cycle measurement
The 10% square wave signal generated by our FPGA can be directly connected to the instrument for measurement, and a stable waveform can be measured. However, when the generated signal is connected to ...
princess. FPGA/CPLD

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2878  46  2056  893  1773  58  1  42  18  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号